Radiofrequency radiation exposure evaluation
According to KDB 447498 D01v06 section 4.3.1, For frequencies below 100 MHz and test
separation distances 50 mm, the Numeric threshold is determined as:
Step a)
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [ f(GHz)]
for 1-g SAR
3.0
Step b)
{[Power allowed at numeric threshold for 50mm in step a)] + [(test separation distance – 50mm) · (f(MHz)/150)]}
mW
Step c) 1)
For test separation distances > 50mm and < 200mm, the power threshold at the corresponding test separation
distance at 100MHz in step b) is multiplied by [1 + log(100/f(MHz))]
Step c) 2)
For test separation distances
100MHz is multiplied by ½.
50mm, the power threshold determined by the equation in c) 1) for 50mm and
>> The fundamental frequency of the EUT is 125kHz, the test separation distance is
(Manufacturer specified the separation distance is: 20mm)
Step a)
>> Numeric threshold, mW / 50mm * 0.1GHz
Numeric threshold 474.3mW
50mm.
3.0
Step b)
>> Numeric threshold
Numeric threshold
474.3mW + (50mm-50mm * 100MHz/150)
474.3mW
Step c) 1) & c) 2)
>> Numeric threshold
Numeric threshold
474.3mW * [1 + log 100/100MHz] * ½
237.15mW
>> The power of EUT measured is: : 51.35 dBµV/m = 0.0000249619mW
Which is smaller than the Numeric threshold.
Therefore, the device is exempt from stand-alone SAR test requirements.
Page 1 of 1
TÜV SÜD Hong Kong Ltd.
3/F, West Wing, Phase 2, 10 Science Park West Avenue, Hong Kong Science Park, Shatin, Hong Kong
Download: 165-00471 Power Distribution Unit RF Exposure Info  Merchandising Technologies Inc.
Mirror Download [FCC.gov]165-00471 Power Distribution Unit RF Exposure Info  Merchandising Technologies Inc.
Document ID4118710
Application IDwD8uhKZuwcY9DquTbh9Qlw==
Document DescriptionRF Exposure Info
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize1.44kB (17975 bits)
Date Submitted2018-12-27 00:00:00
Date Available2018-12-27 00:00:00
Creation Date2018-12-12 15:18:21
Producing SoftwarePDF-XChange 3.60.0106 (Windows)
Document Lastmod2018-12-27 11:01:57
Document TitleRF Exposure Info

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : (none)
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Create Date                     : 2018:12:12 15:18:21+08:00
Modify Date                     : 2018:12:27 11:01:57+08:00
Metadata Date                   : 2018:12:27 11:01:57+08:00
Producer                        : PDF-XChange 3.60.0106 (Windows)
Document ID                     : uuid:af25caa9-7ab1-406c-9d4e-0faa12486004
Instance ID                     : uuid:a1c390b6-dfb4-4948-b208-7281392b5565
Format                          : application/pdf
Page Count                      : 1