FCC ID 2AA5FF1700
VIDEOSCOPE SYSTEM
by Medical Intubation Technology Corp.
Grantee Code: 2AA5F Product Code: F1700
Latest application date: 2018-10-26
FCC ID Device Details
| FCC ID | 2AA5FF1700 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AA5F |
| Product Code | F1700 |
| Applicant Business | Medical Intubation Technology Corp. 🇹🇼 |
| Related Domains | |
| Equipment Class | VIDEOSCOPE SYSTEM |
| Test Firm | Interocean EMC Technology Tin Fu Laboratory |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2018-10-26 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2018-10-26 | PDF 2.1 MB |
| Internal photo | Internal Photos | 2018-10-26 | PDF 2.2 MB |
| External photo | External Photos | 2018-10-26 | PDF 1 MB |
| Label info | ID Label/Location Info | 2018-10-26 | PDF 395.6 KB |
| Label location | ID Label/Location Info | 2018-10-26 | PDF 364 KB |
| Test setup photo | Test Setup Photos | 2018-10-26 | PDF 376.2 KB |
| RF report | Test Report | 2018-10-26 | PDF 669.5 KB |
| Authorization letter | Cover Letter(s) | 2018-10-26 | PDF 64.3 KB |
| Channel declaration | Cover Letter(s) | 2018-10-26 | PDF 92.3 KB |
| Confidential request letter | Cover Letter(s) | 2018-10-26 | PDF 60.5 KB |
| POA | Cover Letter(s) | 2018-10-26 | PDF 28 KB |
| MPE report | RF Exposure Info | 2018-10-26 | PDF 85.4 KB |
| Block diagram Metadata only | Block Diagram | PDF 168.6 KB | |
| Circuit diagram Metadata only | Schematics | PDF 1.1 MB | |
| Circuit diagram RF Metadata only | Schematics | PDF 188.6 KB | |
| Operational description Metadata only | Operational Description | PDF 70 KB |
Application Information
| Application ID | miXlBWYvrX/oGvHyuMMWOQ== |
|---|---|
| Final Action Date | 2018-10-26 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0022952055 |
| Model | F1700 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | VIDEOSCOPE SYSTEM |
| Responsible Party | Li-Chung Chuang, lj.chuang@mitcorp.com.tw |
| Test Firm | benson Tsai, Interocean EMC Technology Tin Fu Laboratory, benson_t@ietc.com.tw |
| TCB Email | TCB@siemic.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| miXlBWYvrX/oGvHyuMMWOQ== | 2018-10-26 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2412-2462 MHz | 0.0137000 | 15C |
Grants
TCB Grant - Application miXlBWYvrX/oGvHyuMMWOQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bureau Veritas Consumer Products Services, Inc. 775 Montague Expressway Milpitas, CA 95035 |
Date of Grant: 10/26/2018 Application Dated: 10/26/2018 |
| Medical Intubation Technology Corp. |
| 2F, No.75, Wenhwa 1st Rd., Guishan District |
| Taoyuan, 33382 Taiwan |
| Attention: Li-Chung Chuang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AA5FF1700 |
| Name of Grantee: | Medical Intubation Technology Corp. |
| Equipment Class: | Digital Transmission System |
| Notes: | VIDEOSCOPE SYSTEM |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.0137 |
| Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. |
EAS Grant - Application miXlBWYvrX/oGvHyuMMWOQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Medical Intubation Technology Corp. 2F, No.75, Wenhwa 1st Rd., Guishan District Taoyuan, 33382 Taiwan |
Date of Grant: 10/26/2018 Application Dated: 10/26/2018 |
| Attention: Li-Chung Chuang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AA5FF1700 |
| Name of Grantee: | Medical Intubation Technology Corp. |
| Equipment Class: | Digital Transmission System |
| Notes: | VIDEOSCOPE SYSTEM |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.0137 |
| Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. |
| Mail To: |