FCC ID 2AA92LV00408

Blood Glucose Monitor

by Livongo Health, Inc.

Grantee Code: 2AA92   Product Code: LV00408
Latest application date: 2016-06-16

Device Images

FCC ID Device Details

FCC ID2AA92LV00408
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AA92
Product CodeLV00408
Applicant BusinessLivongo Health, Inc. 🇺🇸
Related Domains livongo.com
Equipment ClassBlood Glucose Monitor
Test FirmCETECOM Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2016-06-16

Exhibits

DocumentTypeAvailableFile
user guideUsers Manual2016-12-11PDF 1.9 MB
internal photosInternal Photos2016-12-11PDF 458.6 KB
module photoInternal Photos2016-12-11PDF 48.5 KB
external photosExternal Photos2016-12-11PDF 1.2 MB
label infoID Label/Location Info2016-06-16PDF 342 KB
test set-up photos part 22-24-27Test Setup Photos2016-12-11PDF 463.4 KB
test report - delta p22&24&27Test Report2016-06-16PDF 1.7 MB
test report - module p22&24Test Report2016-06-16PDF 3.4 MB
test report - module p27Test Report2016-06-16PDF 1.1 MB
test report part 15bTest Report2016-06-16PDF 625.8 KB
attestation reg validity of conducted module test resultsAttestation Statements2016-06-16PDF 467.5 KB
authorization to signCover Letter(s)2016-06-16PDF 359.6 KB
permanent confidentiality requestCover Letter(s)2016-06-16PDF 583.4 KB
temporary confidentiality requestCover Letter(s)2016-06-16PDF 677 KB
low transmission duty factor analysisRF Exposure Info2016-06-16PDF 295.7 KB
block diagram Metadata onlyBlock DiagramPDF 199.4 KB
block diagram module Metadata onlyBlock DiagramPDF 1.4 MB
schematics Metadata onlySchematicsPDF 2.4 MB
antenna details Metadata onlyOperational DescriptionPDF 3.3 MB
operational and technical description Metadata onlyOperational DescriptionPDF 833.4 KB
technical info module - part a Metadata onlyOperational DescriptionPDF 1.3 MB
technical info module - part b Metadata onlyOperational DescriptionPDF 3 MB
technical info module - part c Metadata onlyOperational DescriptionPDF 681.9 KB
technical info module - part d Metadata onlyOperational DescriptionPDF 1.6 MB
maximum output power information Metadata onlyParts List/Tune Up InfoPDF 326.9 KB
parts list Metadata onlyParts List/Tune Up InfoPDF 109.8 KB

Application Information

Application IDUJrovGE++Gtyw9hsMRYw2Q==
Final Action Date2016-06-16
Application PurposeOriginal Equipment
Applicant FRN0023086168
ModelLV00408
Frequency Range824.2-848.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionBlood Glucose Monitor
Responsible PartyRandy Buswell, Engineering Program Manager, compliance@livongo.com , 866.435.5643
Test FirmKevin Wang, CETECOM Inc., kevin.wang@cetecom.com , 408-586-6271
TCB Emailnikolaus.wahl@cetecom.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date12/11/2016
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsOutput power is ERP for Part 22 and EIRP for Parts 24 and 27. Compliance with FCC RF exposure compliance is based on conservative transmission duty factor analysis along the documented expected use conditions of the equipment. Users must be informed of the operating requirements for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
UJrovGE++Gtyw9hsMRYw2Q==2016-06-16Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz1.422.5ppm244KGXW22H
824.2-848.8 MHz0.42.5ppm249KG7W22H
826.4-846.6 MHz0.212.5ppm4M09F9W22H
1712.4-1752.6 MHz0.422.5ppm4M08F9W27
1850.2-1909.8 MHz1.412.5ppm247KGXW24E
1850.2-1909.8 MHz0.612.5ppm249KG7W24E
1852.4-1907.6 MHz0.422.5ppm4M07F9W24E

Grants

TCB Grant - Application UJrovGE++Gtyw9hsMRYw2Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CETECOM Inc.
411 Dixon Landing Road
Milpitas, CA 95035
Date of Grant: 06/16/2016

Application Dated: 06/13/2016
Livongo Health, Inc.
150 W. Evelyn Ave
Suite 150
Mountain View, CA 94041
 
Attention: Randy Buswell , Engineering Program Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AA92LV00408
Name of Grantee:  Livongo Health, Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Blood Glucose Monitor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.42 2.5  PM 244KGXW
22H 824.2  -  848.8 0.4 2.5  PM 249KG7W
22H 826.4  -  846.6 0.21 2.5  PM 4M09F9W
24E 1850.2  -  1909.8 1.41 2.5  PM 247KGXW
24E 1850.2  -  1909.8 0.61 2.5  PM 249KG7W
24E 1852.4  -  1907.6 0.42 2.5  PM 4M07F9W
27 1712.4  -  1752.6 0.42 2.5  PM 4M08F9W

Output power is ERP for Part 22 and EIRP for Parts 24 and 27.

Compliance with FCC RF exposure compliance is based on conservative transmission duty factor analysis along the documented expected use conditions of the equipment.

Users must be informed of the operating requirements for satisfying RF exposure compliance.


EAS Grant - Application UJrovGE++Gtyw9hsMRYw2Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Livongo Health, Inc.
150 W. Evelyn Ave Suite 150
Mountain View, CA 94041
United States
  Date of Grant: 06/16/2016

Application Dated: 06/13/2016
 
Attention: Randy Buswell , Engineering Program Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AA92LV00408
Name of Grantee:  Livongo Health, Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Blood Glucose Monitor
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.42 2.5  PM 244KGXW
22H 824.2  -  848.8 0.4 2.5  PM 249KG7W
22H 826.4  -  846.6 0.21 2.5  PM 4M09F9W
24E 1850.2  -  1909.8 1.41 2.5  PM 247KGXW
24E 1850.2  -  1909.8 0.61 2.5  PM 249KG7W
24E 1852.4  -  1907.6 0.42 2.5  PM 4M07F9W
27 1712.4  -  1752.6 0.42 2.5  PM 4M08F9W

Output power is ERP for Part 22 and EIRP for Parts 24 and 27.

Compliance with FCC RF exposure compliance is based on conservative transmission duty factor analysis along the documented expected use conditions of the equipment.

Users must be informed of the operating requirements for satisfying RF exposure compliance.



Mail To: