FCC ID 2AAU7-AHP

Alloy Hub+

by Tri plus grupa d.o.o.

Grantee Code: 2AAU7   Product Code: AHP
Latest application date: 2023-08-03

FCC ID Device Details

FCC ID2AAU7-AHP
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AAU7
Product CodeAHP
Applicant BusinessTri plus grupa d.o.o. 🇭🇷
Related Domains zipato.com
Equipment ClassAlloy Hub+
Test FirmShenzhen NTEK Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2023-08-03
5745-5825 MHzOriginal Equipment2023-08-03
2402-2480 MHzOriginal Equipment2023-08-03
908.4-916 MHzOriginal Equipment2023-08-03

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2024-01-31PDF 1.4 MB
Internal PhotosInternal Photos2024-01-31PDF 1.8 MB
Internal photosInternal Photos2024-01-31PDF 1.8 MB
External PhotoExternal Photos2024-01-31PDF 522.7 KB
External PhotosExternal Photos2024-01-31PDF 522.7 KB
External photosExternal Photos2024-01-31PDF 522.7 KB
LabelID Label/Location Info2023-08-03PDF 1 MB
T Setup photoTest Setup Photos2024-01-31PDF 303.9 KB
T Setup photoTest Setup Photos2024-01-31PDF 303.6 KB
T Setup photoTest Setup Photos2024-01-31PDF 307.6 KB
Test Setup PhotosTest Setup Photos2024-01-31PDF 528.4 KB
-5GWIFI With DFS R3Test Report2023-08-03PDF 3.4 MB
AntennaTest Report2023-08-03PDF 3.2 MB
Attachment for 5G WIFI part1Test Report2023-08-03PDF 3.5 MB
Attachment for 5G WIFI part2Test Report2023-08-03PDF 3.6 MB
Attachment for 5G WIFI part3Test Report2023-08-03PDF 2.9 MB
AttestationTest Report2023-08-03PDF 3.2 MB
Test ReportTest Report2023-08-03PDF 1.6 MB
Test ReportTest Report2023-08-03PDF 4.9 MB
Test Report2.4G WIFI R3Test Report2023-08-03PDF 4 MB
Test ReportBLE_Matter R3Test Report2023-08-03PDF 5.2 MB
antenna reportTest Report2023-08-03PDF 3.2 MB
2.911 (d)(5)(i)CertificationEquipmentTypev1.2(1)Attestation Statements2023-08-03PDF 271.5 KB
2.911 (d)(5)(ii)CertificiationApplicantv1.2(1)Attestation Statements2023-08-03PDF 223.4 KB
2.911_(d)(5)(i)CertificationEquipmentTypev1.2Attestation Statements2023-08-03PDF 271.5 KB
2.911_(d)(5)(ii)CertificiationApplicantv1.2Attestation Statements2023-08-03PDF 223.4 KB
2.911_(d)(7) US Agent for Service of Process v1.2Attestation Statements2023-08-03PDF 134.3 KB
2.911_(d)(7) US Agent for Service of Process v1.3Attestation Statements2023-08-03PDF 134.3 KB
Agent Authorization Rev 1.0Cover Letter(s)2023-08-03PDF 94.3 KB
AgentAuthorizationRev1.0Cover Letter(s)2023-08-03PDF 94.3 KB
FCC Short_Long Term Confidentiality Request Rev4.1Cover Letter(s)2023-08-03PDF 118.4 KB
FCC Software Configuration Control Declaration Rev1.0Cover Letter(s)2023-08-03PDF 168.2 KB
RF ExposureRF Exposure Info2023-08-03PDF 297.1 KB
RFexposureRF Exposure Info2023-08-03PDF 297.1 KB
Block Metadata onlyBlock DiagramPDF 208.9 KB
Block Diagram Metadata onlyBlock DiagramPDF 208.9 KB
SCH Metadata onlySchematicsPDF 1.7 MB
OP Metadata onlyOperational DescriptionPDF 148.5 KB
software security requirement Metadata onlySDR Software/Security InfPDF 275.7 KB

Application Information

Application IDxVFKj1BLRS5185v3HWomzA==
Final Action Date2023-08-03
Application PurposeOriginal Equipment
Applicant FRN0022962427
ModelAHP
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionAlloy Hub+
Responsible PartySebastian Popovic, spopovic@zipato.com , 385913145101
Technical ContactTri plus grupa d.o.o., spopovic@zipato.com
Test FirmAlex Li, Shenzhen NTEK Testing Technology Co., Ltd., certification@ntek.org.cn , +86-755-6115-9384
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date01/31/2024
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
xVFKj1BLRS5185v3HWomzA==2023-08-03Original Equipment
Zma1eHq5WrUMSKXVGI+fhA==2023-08-03Original Equipment
Hd/iGW1BIjjR8dTyVE/eHg==2023-08-03Original Equipment
9xMuE3RnBCtpKSMd7V1xCg==2023-08-03Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
908.4-916 MHz15CCC
2402-2480 MHz0.002754015CCC
2402-2480 MHz0.00119915CCC
2412-2462 MHz0.0468815CCC
2414 MHz0.00420715CCC
5180-5240 MHz0.02202915ECC
5260-5320 MHz0.02142915ECC, ND
5500-5700 MHz0.01945415ECC, ND
5745-5825 MHz0.02233615ECC

Grants

TCB Grant - Application Zma1eHq5WrUMSKXVGI+fhA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/03/2023

Application Dated: 08/03/2023
Tri plus grupa d.o.o.
Banjavciceva 11
10000 Zagreb,
Croatia
 
Attention: Sebastian Popovic

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAU7-AHP
Name of Grantee:  Tri plus grupa d.o.o.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Alloy Hub+
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.022029  
CC ND 15E 5260.0  -  5320.0 0.021429  
CC ND 15E 5500.0  -  5700.0 0.019454  
CC 15E 5745.0  -  5825.0 0.022336  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application Zma1eHq5WrUMSKXVGI+fhA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Tri plus grupa d.o.o.
Banjavciceva 11
10000 Zagreb,
Croatia
  Date of Grant: 08/03/2023

Application Dated: 08/03/2023
 
Attention: Sebastian Popovic

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAU7-AHP
Name of Grantee:  Tri plus grupa d.o.o.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Alloy Hub+
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.022029  
CC ND 15E 5260.0  -  5320.0 0.021429  
CC ND 15E 5500.0  -  5700.0 0.019454  
CC 15E 5745.0  -  5825.0 0.022336  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application xVFKj1BLRS5185v3HWomzA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/03/2023

Application Dated: 08/03/2023
Tri plus grupa d.o.o.
Banjavciceva 11
10000 Zagreb,
Croatia
 
Attention: Sebastian Popovic

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAU7-AHP
Name of Grantee:  Tri plus grupa d.o.o.
Equipment Class: Digital Transmission System
Notes: Alloy Hub+
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.001199  
CC 15C 2414.0  -  2414.0 0.004207  
CC 15C 2412.0  -  2462.0 0.04688  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application xVFKj1BLRS5185v3HWomzA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Tri plus grupa d.o.o.
Banjavciceva 11
10000 Zagreb,
Croatia
  Date of Grant: 08/03/2023

Application Dated: 08/03/2023
 
Attention: Sebastian Popovic

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAU7-AHP
Name of Grantee:  Tri plus grupa d.o.o.
Equipment Class: Digital Transmission System
Notes: Alloy Hub+
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.001199  
CC 15C 2414.0  -  2414.0 0.004207  
CC 15C 2412.0  -  2462.0 0.04688  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application Hd/iGW1BIjjR8dTyVE/eHg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/03/2023

Application Dated: 08/03/2023
Tri plus grupa d.o.o.
Banjavciceva 11
10000 Zagreb,
Croatia
 
Attention: Sebastian Popovic

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAU7-AHP
Name of Grantee:  Tri plus grupa d.o.o.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Alloy Hub+
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.002754  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application Hd/iGW1BIjjR8dTyVE/eHg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Tri plus grupa d.o.o.
Banjavciceva 11
10000 Zagreb,
Croatia
  Date of Grant: 08/03/2023

Application Dated: 08/03/2023
 
Attention: Sebastian Popovic

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAU7-AHP
Name of Grantee:  Tri plus grupa d.o.o.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Alloy Hub+
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.002754  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 9xMuE3RnBCtpKSMd7V1xCg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/03/2023

Application Dated: 08/03/2023
Tri plus grupa d.o.o.
Banjavciceva 11
10000 Zagreb,
Croatia
 
Attention: Sebastian Popovic

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAU7-AHP
Name of Grantee:  Tri plus grupa d.o.o.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Alloy Hub+
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.4  -  916.0  


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 9xMuE3RnBCtpKSMd7V1xCg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Tri plus grupa d.o.o.
Banjavciceva 11
10000 Zagreb,
Croatia
  Date of Grant: 08/03/2023

Application Dated: 08/03/2023
 
Attention: Sebastian Popovic

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAU7-AHP
Name of Grantee:  Tri plus grupa d.o.o.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Alloy Hub+
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.4  -  916.0  


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: