151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.

Computime Ltd. Electrically heated bedding control

Page 1 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 2 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 3 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 4 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 5 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 6 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 7 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 8 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 9 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 10 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 11 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 12 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 13 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 14 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 15 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 16 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 17 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 18 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 19 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 20 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 21 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 22 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 23 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 24 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 25 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Page 26 of 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.

Global United Technology Services Co., Ltd.
Report No.: GTS201803000046F01
Cover Page
FCC REPORT
Applicant:
Computime Ltd.
Address of Applicant:
6/F, Bldg 20E, Phase 3, Hong Kong Science Park, 20 Science
Park East Ave, Shatin, New Territories, Hong Kong
Computime Electronics(Shenzhen)Company Limited
Manufacturer/Factory:
Address of
Manufacturer/Factory:
Yuekenguangyu Industrial Park,Kangqiao Road 88#,
Danzhutou Community,Nanwan Street Office Longgang
District,Shenzhen,China
Equipment Under Test (EUT)
Product Name:
Electrically heated bedding control
Model No.:
L85B, L85KQB
Trade Mark:
Sunbeam
FCC ID:
2AAUQ-151161CT
Applicable standards:
FCC CFR Title 47 Part 15 Subpart C Section 15.231
Date of sample receipt:
March 06, 2018
Date of Test:
March 06- April 11, 2018
Date of report issued:
April 12, 2018
Test Result :
PASS *
In the configuration tested, the EUT complied with the standards specified above.
Authorized Signature:
Robinson Lo
Laboratory Manager
This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in
full, without prior written permission of the company. The report would be invalid without specific stamp of test institute
and the signatures of compiler and approver.
Report No.: GTS201803000046F01
Version
Version No.
Date
Description
00
April 12, 2018
Original
Prepared By:
Date:
April 12, 2018
Date:
April 12, 2018
Project Engineer
Check By:
Reviewer
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 2 of 26
Report No.: GTS201803000046F01
Contents
Page
COVER PAGE .......................................................................................................................................... 1
VERSION .................................................................................................................................................. 2
CONTENTS .............................................................................................................................................. 3
TEST SUMMARY ..................................................................................................................................... 4
4.1
MEASUREMENT UNCERTAINTY ............................................................................................................ 4
GENERAL INFORMATION ...................................................................................................................... 5
5.1
5.2
5.3
5.4
5.5
GENERAL DESCRIPTION OF EUT ......................................................................................................... 5
TEST MODE ........................................................................................................................................ 6
TEST FACILITY.................................................................................................................................... 6
TEST LOCATION ................................................................................................................................. 6
OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 6
TEST INSTRUMENTS LIST ..................................................................................................................... 7
TEST RESULTS AND MEASUREMENT DATA...................................................................................... 8
7.1
ANTENNA REQUIREMENT ..................................................................................................................... 8
7.2
RADIATED EMISSION METHOD ............................................................................................................. 9
7.2.1 Field Strength of the Fundamental Signal ................................................................................. 12
7.2.2 Restriction bands emissions ...................................................................................................... 12
7.2.3 Spurious emissions .................................................................................................................... 13
7.3
20DB OCCUPY BANDWIDTH .............................................................................................................. 17
7.4
DEACTIVATION TESTING .................................................................................................................... 18
TEST SETUP PHOTO ............................................................................................................................ 19
EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 20
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 3 of 26
Report No.: GTS201803000046F01
Test Summary
Test Item
Section in CFR 47
Result
Antenna requirement
15.203
Pass
Restricted bands of operation.
15.205
Pass
Conduction Emission
15.207
Not applicable
Spurious Emissions
15.231(b) &15.209
Pass
20dB Bandwidth
15.231(c)
Pass
Deactivation Testing
15.231(a)(1)
Pass
Pass: The EUT complies with the essential requirements in the standard.
4.1
Measurement Uncertainty
Test Item
Frequency Range
Measurement Uncertainty
Notes
Radiated Emission
9kHz ~ 30MHz
 4.34dB
(1)
Radiated Emission
30MHz ~ 1000MHz
 4.24dB
(1)
Radiated Emission
1GHz ~ 26.5GHz
 4.68dB
(1)
AC Power Line Conducted
Emission
0.15MHz ~ 30MHz
 3.45dB
(1)
Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 4 of 26
Report No.: GTS201803000046F01
General Information
5.1 General Description of EUT
Product Name:
Electrically heated bedding control
Model No.:
L85B, L85KQB
Test Model:
L85KQB
Remark:
L85B is a single select zone controller; L85KQB is a two select zone
controller. They are same in RF spec., the difference between the
models is controller zone can be choose
Serial No.:
N/A
Test sample(s) ID:
GTS201803000046-1
Sample(s) Status:
Engineer sample
Hardware:
REMOTE_r3.0
Software:
Operation Frequency:
418MHz
Channel numbers:
Modulation technology:
GFSK
Antenna Type:
Integral Antenna
Power supply:
DC 4.5V 3*1.5V Size “AAA” battery
Labeling:
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 5 of 26
Report No.: GTS201803000046F01
5.2 Test mode
Transmitting mode
Keep the EUT in transmitting mode.
Remark: New battery is used during all test. So the report just shows that condition’s data.
Per-test mode.
We have verified the construction and function in typical operation, The EUT was placed on three different
polar directions; i.e. X axis, Y axis, Z axis. only Worse case Y axis is reported:
Axis
Field Strength(dBuV/m)
78.34
78.39
77.69
Final Test Mode:
According to ANSI C63.10 standards, the test results are both the “worst case” and “worst setup”:
Y axis (see the test setup photo)
5.3 Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
● FCC —Registration No.: 381383
Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and
fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance
letter from the FCC is maintained in files. Registration 381383, January 08, 2018.
● Industry Canada (IC) —Registration No.: 9079A-2
The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been
registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
with Registration No.: 9079A-2, August 15, 2016.
5.4 Test Location
All tests were performed at:
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Tel: 0755-27798480
Fax: 0755-27798960
5.5 Other Information Requested by the Customer
None.
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 6 of 26
Report No.: GTS201803000046F01
Test Instruments list
RF Test
Item
Test Equipment
Manufacturer
Model No.
Inventory
No.
Cal.Date
(mm-dd-yy)
Cal.Due date
(mm-dd-yy)
3m Semi- Anechoic
Chamber
ZhongYu Electron
9.2(L)*6.2(W)* 6.4(H)
GTS250
July 03 2015
July 02 2020
Control Room
ZhongYu Electron
6.2(L)*2.5(W)* 2.4(H)
GTS251
N/A
N/A
Spectrum Analyzer
Agilent
E4440A
GTS533
June 28 2017
June 27 2018
EMI Test Receiver
Rohde & Schwarz
ESU26
GTS203
June 28 2017
June 27 2018
VULB9163
GTS214
June 28 2017
June 27 2018
9120D-829
GTS208
June 28 2017
June 27 2018
SCHWARZBECK
MESS-ELEKTRONIK
Double -ridged waveguide SCHWARZBECK
horn
MESS-ELEKTRONIK
BiConiLog Antenna
Horn Antenna
ETS-LINDGREN
3160
GTS217
June 28 2017
June 27 2018
EMI Test Software
AUDIX
E3
N/A
N/A
N/A
Coaxial Cable
GTS
N/A
GTS213
June 28 2017
June 27 2018
10
Coaxial Cable
GTS
N/A
GTS211
June 28 2017
June 27 2018
11
Coaxial cable
GTS
N/A
GTS210
June 28 2017
June 27 2018
12
Coaxial Cable
GTS
N/A
GTS212
June 28 2017
June 27 2018
13
Amplifier(100kHz-3GHz)
HP
8347A
GTS204
June 28 2017
June 27 2018
14
Amplifier(2GHz-20GHz)
HP
8349B
GTS206
June 28 2017
June 27 2018
15
Amplifier (18-26GHz)
Rohde & Schwarz
AFS33-18002
650-30-8P-44
GTS218
June 28 2017
June 27 2018
16
Band filter
Amindeon
82346
GTS219
June 28 2017
June 27 2018
17
Power Meter
Anritsu
ML2495A
GTS540
June 28 2017
June 27 2018
18
Power Sensor
Anritsu
MA2411B
GTS541
June 28 2017
June 27 2018
19
Loop Antenna
Zhinan
ZN30900A
GTS215
June. 28 2017 June. 27 2018
General used equipment:
Item
Test Equipment
Barometer
Manufacturer
ChangChun
Model No.
DYM3
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Inventory
No.
GTS257
Cal.Date
(mm-dd-yy)
June 28 2017
Cal.Due date
(mm-dd-yy)
June 27 2018
Page 7 of 26
Report No.: GTS201803000046F01
Test results and Measurement Data
7.1 Antenna requirement
Standard requirement:
FCC Part15 C Section 15.203
15.203 requirement:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so
that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical
connector is prohibited.
EUT Antenna:
The antenna is Integral antenna, the best case gain of the antenna please refer to antenna data sheet
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 8 of 26
Report No.: GTS201803000046F01
7.2 Radiated Emission Method
Test Requirement:
FCC Part15 C Section 15.205, 15.209 & 15.231(b)
Test Method:
ANSI C63.10:2013
Test Frequency Range:
30MHz to 5GHz
Test site:
Measurement Distance: 3m
Receiver setup:
Limit:
(Transmitter Field Strength
of Emissions)
Limit:
(Spurious Emissions)
Test setup:
Frequency
Detector
RBW
VBW
Remark
30MHz1GHz
Quasi-peak
120KHz
300KHz
Quasi-peak Value
Above 1GHz
Peak
1MHz
3MHz
Peak Value
Frequency
418MHz
Limit (dBuV/m @3m)
80.28
100.28
Remark
Average Value
Peak Value
Frequency
30MHz-88MHz
88MHz-216MHz
216MHz-960MHz
960MHz-1GHz
Limit (uV/m)
Remark
100 @3m
Quasi-peak Value
150 @3m
Quasi-peak Value
200 @3m
Quasi-peak Value
500 @3m
Quasi-peak Value
500 @3m
Average Value
Above 1GHz
5000 @3m
Peak Value
Or The maximum permitted unwanted emission level is 20 dB below the
maximum permitted fundamental level whichever limit permits a higher field
strength.
Below 1GHz
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 9 of 26
Report No.: GTS201803000046F01
Above 1GHz
Test Procedure:
1. During the test, the New Battery was used.
2. The EUT was placed on the top of a rotating table (0.8 meters for below
1GHz and 1.5 meters for above 1GHz) above the ground at a 3 meter
camber. The table was rotated 360 degrees to determine the position of
the highest radiation.
3. The EUT was set 3 meters away from the interference-receiving
antenna, which was mounted on the top of a variable-height antenna
tower.
4. The antenna height is varied from one meter to four meters above the
ground to determine the maximum value of the field strength. Both
horizontal and vertical polarizations of the antenna are set to make the
measurement.
5. For each suspected emission, the EUT was arranged to its worst case
and then the antenna was tuned to heights from 1 meter to 4 meters
and the rota table was turned from 0 degrees to 360 degrees to find the
maximum reading.
6. The test-receiver system was set to Peak Detect Function and
Specified Bandwidth with Maximum Hold Mode.
7. If the emission level of the EUT in peak mode was 10dB lower than the
limit specified, then testing could be stopped and the peak values of the
EUT would be reported. Otherwise the emissions that did not have
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 10 of 26
Report No.: GTS201803000046F01
10dB margin would be re-tested one by one using peak, quasi-peak or
average method as specified and then reported in a data sheet.
Test Instruments:
Refer to section 6.0 for details
Test mode:
Refer to section 5.2 for details
Test results:
Pass
Measurement data:
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 11 of 26
Report No.: GTS201803000046F01
7.2.1
Field Strength of the Fundamental Signal
QP Value:
Frequency
(MHz)
Read
Level
(dBuV)
Antenna
Factor
(dB/m)
Cable
Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit Line
(dBuV/m)
Over
Limit
(dB)
polarization
418
97.11
15.86
2.94
37.52
78.39
80.28
-1.89
Vertical
418
94.11
15.86
2.94
37.52
75.39
80.28
-4.89
Horizontal
Over
Limit
(dB)
polarization
-26.59
Vertical
7.2.2
Restriction bands emissions
All of the restriction bands were tested, and only the data of worst case was exhibited.
QP value:
Read
Antenna
Cable
Preamp
Frequency
Level
Limit Line
Level
Factor
Loss
Factor
(MHz)
(dBuV/m)
(dBuV/m)
(dBuV)
(dB/m)
(dB)
(dB)
410
38.34
15.86
2.94
37.52
19.41
46.00
410
36.11
15.86
2.94
37.52
17.18
46.00
-28.82
Remark:
1.Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 12 of 26
Horizontal
Report No.: GTS201803000046F01
7.2.3

Spurious emissions
Below 30MHz
The emission from 9 kHz to 30MHz was pre-tested and found the result was 20dB lower than the limit,
and according to 15.31(o), the test result no need to reported.

Below 1GHz
Horizontal
Frequency
(MHz)
Read
Level
(dBuV)
Antenna
Factor
(dB/m)
Cable
Loss
(dB)
Preamp
Factor
(dB)
Quasipeak
Value
(dBuV/m)
Limit Line
(dBuV/m)
Over
Limit
(dB)
Polarization
836
60.30
21.62
4.60
37.61
48.91
60.28
-11.37
Horizontal
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 13 of 26
Report No.: GTS201803000046F01
Vertical
Frequency
(MHz)
Read
Level
(dBuV)
Antenna
Factor
(dB/m)
Cable
Loss
(dB)
Preamp
Factor
(dB)
Quasipeak
Value
(dBuV/m)
Limit Line
(dBuV/m)
Over
Limit
(dB)
Polarization
836
49.98
21.62
4.60
37.61
38.59
60.28
-21.69
Vertical
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 14 of 26
Report No.: GTS201803000046F01

Above 1GHz
Horizontal
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 15 of 26
Report No.: GTS201803000046F01
Vertical
Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 16 of 26
Report No.: GTS201803000046F01
7.3 20dB Occupy Bandwidth
Test Requirement:
FCC Part15 C Section 15.231 (c)
Test Method:
ANSI C63.10:2013
Limit:
The bandwidth of the emission shall be no wider than 0.25% of the center
frequency for devices operating above 70 MHz and below 900MHz. For
devices operating above 900 MHz, the emission shall be no wider than
0.5% of the center frequency. Bandwidth is determined at the points 20 dB
down from the modulated carrier.
Test setup:
Test Instruments:
Refer to section 6.0 for details
Test mode:
Refer to section 5.2 for details
Test results:
Pass
Measurement Data
Test Frequency (MHz)
20dB bandwidth (MHz)
Limit (MHz)
Result
418
0.1007
1.045
Pass
Note: Limit (418MHz) = Fundamental frequency×0.25%=418×0.25%=1.045MHz
Test plot as follows:
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 17 of 26
Report No.: GTS201803000046F01
7.4 Deactivation Testing
Test Requirement:
FCC Part15 C Section 15.231 (a)(1)
Test Method:
ANSI C63.10:2013
Receiver setup:
RBW=1MHz, VBW=1MHz, span=0Hz, detector: Peak
Limit:
Not more than 5 seconds
Test setup:
Test Instruments:
Refer to section 6.0 for details
Test mode:
Refer to section 5.2 for details
Pass
Test results:
Measurement data:
Test Frequency
(MHz)
418
Activation Time
(second)
0.06833
Limit
(second)
<5.0
Result
Pass
Test plot as follows:
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 18 of 26
Report No.: GTS201803000046F01
Test Setup Photo
Radiated Emission
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 19 of 26
Report No.: GTS201803000046F01
EUT Constructional Details
L85KQB
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 20 of 26
Report No.: GTS201803000046F01
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 21 of 26
Report No.: GTS201803000046F01
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 22 of 26
Report No.: GTS201803000046F01
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 23 of 26
Report No.: GTS201803000046F01
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 24 of 26
Report No.: GTS201803000046F01
L85B
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 25 of 26
Report No.: GTS201803000046F01
------ End ------
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 26 of 26
Download: 151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Mirror Download [FCC.gov]151161CT Electrically heated bedding control Test Report HD 271 S1 Computime Ltd.
Document ID3887026
Application IDGSuX5TorUeaysFBZ7NGoPw==
Document DescriptionTest Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize200.77kB (2509585 bits)
Date Submitted2018-06-13 00:00:00
Date Available2018-06-13 00:00:00
Creation Date2018-06-13 22:48:03
Producing SoftwareMicrosoft® Word 2016
Document Lastmod2018-06-13 22:48:03
Document TitleHD 271 S1
Document CreatorMicrosoft® Word 2016
Document Author: LAB02

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Page Count                      : 26
Language                        : zh-CN
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Microsoft® Word 2016
Title                           : HD 271 S1
Creator                         : LAB02
Creator Tool                    : Microsoft® Word 2016
Create Date                     : 2018:06:13 22:48:03+08:00
Modify Date                     : 2018:06:13 22:48:03+08:00
Document ID                     : uuid:3E20B5FA-4492-417E-993B-CABF141B3C2F
Instance ID                     : uuid:3E20B5FA-4492-417E-993B-CABF141B3C2F
Author                          : LAB02