FCC ID 2AAWH-PILLBOXURI1
MedMinder Uri 1
by MedMinder Systems, Inc.
Grantee Code: 2AAWH Product Code: PILLBOXURI1
Latest application date: 2025-11-19
FCC ID Device Details
| FCC ID | 2AAWH-PILLBOXURI1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AAWH |
| Product Code | PILLBOXURI1 |
| Applicant Business | MedMinder Systems, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | MedMinder Uri 1 |
| Test Firm | Shenzhen LGT Test Service Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1860-1900 MHz | Original Equipment | 2025-11-19 |
| 2402-2480 MHz | Original Equipment | 2025-11-19 |
| 2412-2462 MHz | Original Equipment | 2025-11-19 |
| 5745-5825 MHz | Original Equipment | 2025-11-19 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2025-11-19 | PDF 344.4 KB |
| Internal Photos | Internal Photos | 2025-11-19 | PDF 2 MB |
| External Photos | External Photos | 2025-11-19 | PDF 560.6 KB |
| Label and Label location | ID Label/Location Info | 2025-11-19 | PDF 140.8 KB |
| Test Setup Photo | Test Setup Photos | 2025-11-19 | PDF 220.8 KB |
| Test Setup Photo | Test Setup Photos | 2025-11-19 | PDF 245 KB |
| Test Setup Photo | Test Setup Photos | 2025-11-19 | PDF 432.1 KB |
| Test Report | Test Report | 2025-11-19 | PDF 1.4 MB |
| Test Report | Test Report | 2025-11-19 | PDF 5.4 MB |
| Test Report | Test Report | 2025-11-19 | PDF 3.5 MB |
| Test Report | Test Report | 2025-11-19 | PDF 4.4 MB |
| Test Report | Test Report | 2025-11-19 | PDF 3.7 MB |
| Test Report | Test Report | 2025-11-19 | PDF 5 MB |
| Test Report | Test Report | 2025-11-19 | PDF 5.5 MB |
| Attestation Statements of US Agent for Service of Process, 2.911(d)(7) | Attestation Statements | 2025-11-19 | PDF 71.4 KB |
| Attestation Statements of US Agent for Service of Process, 2.911(d)(7) Metadata only | Attestation Statements | 2025-11-19 | PDF 71.8 KB |
| Attestation of Covered Equipment, 2.911(d)(5)(i)(ii) | Attestation Statements | 2025-11-19 | PDF 108.8 KB |
| FCC Software Security Requirements for UNII devices Rev | Attestation Statements | 2025-11-19 | PDF 71.4 KB |
| ANT Report | Cover Letter(s) | 2025-11-19 | PDF 526.3 KB |
| Agent Authorization Letter Template | Cover Letter(s) | 2025-11-19 | PDF 189.4 KB |
| FCC Short & Long Term Confidentiality Request | Cover Letter(s) | 2025-11-19 | PDF 88.8 KB |
| FCC Software Configuration Control Declaration | Cover Letter(s) | 2025-11-19 | PDF 93.3 KB |
| RF Exposure | RF Exposure Info | 2025-11-19 | PDF 1.7 MB |
| RF Exposure | RF Exposure Info | 2025-11-19 | PDF 5.5 MB |
| RF Exposure | RF Exposure Info | 2025-11-19 | PDF 4.6 MB |
| Block Diagram Metadata only | Block Diagram | PDF 94.9 KB | |
| SCH Metadata only | Schematics | PDF 778.1 KB | |
| OPS Metadata only | Operational Description | PDF 80.1 KB | |
| BOM Metadata only | SDR Software/Security Info. | PDF 99.2 KB | |
| SOFTWARE SECURITY REQUIREMENTS FOR U-NII DEVICES Metadata only | SDR Software/Security Info. | PDF 140.6 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 99.2 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 215.1 KB | |
| Tune Up Procedure Metadata only | Parts List/Tune Up Info | PDF 215.1 KB |
Application Information
| Application ID | rIVXCHY/iTEpZSEPCwUd8w== |
|---|---|
| Final Action Date | 2025-11-19 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0022933303 |
| Model | PILLBOXURI1 |
| Frequency Range | 1860-1900 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | MedMinder Uri 1 |
| Responsible Party | Russell Reier, russell@medminder.com |
| Technical Contact | MedMinder Systems, Inc., eran@medminder.com |
| Test Firm | Wen Wen, Shenzhen LGT Test Service Co., Ltd., qa@lgt-cert.com |
| TCB Email | anezam@qai.org |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| rIVXCHY/iTEpZSEPCwUd8w== | 2025-11-19 | Original Equipment |
| NtxT5Dns52BBeAAdRoa8+w== | 2025-11-19 | Original Equipment |
| MKBXBRou1L3VUIAMM1Oj2g== | 2025-11-19 | Original Equipment |
| Im4enEUE4rjMxilSC9G7UA== | 2025-11-19 | Original Equipment |
| AqMPjqSTRvv6TR10kUYQkA== | 2025-11-19 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 824.2-848.8 MHz | 1.7061 | 2.5 PM | 247KGXW | 22H | |
| 824.2-848.8 MHz | 1.6596 | 2.5 PM | 251KG7W | 22H | |
| 1850.2-1909.8 MHz | 1.3583 | 2.5 PM | 247KGXW | 24E | |
| 1850.2-1909.8 MHz | 1.6255 | 2.5 PM | 246KG7W | 24E | |
| 1852.4-1907.6 MHz | 0.3296 | 2.5 PM | 4M18F9W | 24E | |
| 826.4-846.6 MHz | 0.2355 | 2.5 PM | 4M18F9W | 22H | |
| 1860-1900 MHz | 0.3319 | 2.5 PM | 18M1G7D | 24E | |
| 1852.5-1907.5 MHz | 0.3491 | 2.5 PM | 4M51G7D | 24E | |
| 1860-1900 MHz | 0.278 | 2.5 PM | 18M0W7D | 24E | |
| 1852.5-1907.5 MHz | 0.3027 | 2.5 PM | 4M52W7D | 24E | |
| 1720-1745 MHz | 0.2624 | 2.5 PM | 18M0G7D | 27 | |
| 1711.5-1753.5 MHz | 0.2864 | 2.5 PM | 2M70G7D | 27 | |
| 1720-1745 MHz | 0.2208 | 2.5 PM | 18M0W7D | 27 | |
| 1712.5-1752.5 MHz | 0.2399 | 2.5 PM | 4M51W7D | 27 | |
| 829-844 MHz | 0.2065 | 2.5 PM | 9M03G7D | 22H | |
| 826.5-846.5 MHz | 0.2173 | 2.5 PM | 4M52G7D | 22H | |
| 829-844 MHz | 0.177 | 2.5 PM | 9M02W7D | 22H | |
| 826.5-846.5 MHz | 0.1871 | 2.5 PM | 4M51W7D | 22H | |
| 704-711 MHz | 0.1849 | 2.5 PM | 9M07G7D | 27 | |
| 700.5-714.5 MHz | 0.1892 | 2.5 PM | 2M70G7D | 27 | |
| 704-711 MHz | 0.1589 | 2.5 PM | 9M07W7D | 27 | |
| 701.5-713.5 MHz | 0.1722 | 2.5 PM | 4M52W7D | 27 | |
| 709-711 MHz | 0.1858 | 2.5 PM | 8M96G7D | 27 | |
| 706.5-713.5 MHz | 0.1871 | 2.5 PM | 4M55G7D | 27 | |
| 709-711 MHz | 0.16 | 2.5 PM | 8M92W7D | 27 | |
| 706.5-713.5 MHz | 0.171 | 2.5 PM | 4M56W7D | 27 | |
| 1720-1770 MHz | 0.2333 | 2.5 PM | 18M2G7D | 27 | |
| 1711.5-1778.5 MHz | 0.2506 | 2.5 PM | 2M70G7D | 27 | |
| 1720-1770 MHz | 0.1945 | 2.5 PM | 18M2W7D | 27 | |
| 1711.5-1778.5 MHz | 0.2042 | 2.5 PM | 2M70W7D | 27 | |
| 2402-2480 MHz | 0.0058 | 15C | CC | ||
| 2402-2480 MHz | 0.0038 | 15C | CC | ||
| 2412-2462 MHz | 0.0537 | 15C | CC | ||
| 15B | CC | ||||
| 5180-5240 MHz | 0.0097 | 15E | CC | ||
| 5260-5320 MHz | 0.0105 | 15E | CC ND | ||
| 5500-5700 MHz | 0.0121 | 15E | CC ND | ||
| 5745-5825 MHz | 0.0123 | 15E | CC |
Grants
TCB Grant - Application rIVXCHY/iTEpZSEPCwUd8w==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 11/19/2025 Application Dated: 11/19/2025 |
| MedMinder Systems, Inc. |
| 320 Norwood Park South |
| Norwood, MA 02062 |
| Attention: Russell Reier , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AAWH-PILLBOXURI1 |
| Name of Grantee: | MedMinder Systems, Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | MedMinder Uri 1 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 1.7061 | 2.5 PM | 247KGXW | |
| 22H | 824.2 - 848.8 | 1.6596 | 2.5 PM | 251KG7W | |
| 24E | 1850.2 - 1909.8 | 1.3583 | 2.5 PM | 247KGXW | |
| 24E | 1850.2 - 1909.8 | 1.6255 | 2.5 PM | 246KG7W | |
| 24E | 1852.4 - 1907.6 | 0.3296 | 2.5 PM | 4M18F9W | |
| 22H | 826.4 - 846.6 | 0.2355 | 2.5 PM | 4M18F9W | |
| 24E | 1860.0 - 1900.0 | 0.3319 | 2.5 PM | 18M1G7D | |
| 24E | 1852.5 - 1907.5 | 0.3491 | 2.5 PM | 4M51G7D | |
| 24E | 1860.0 - 1900.0 | 0.278 | 2.5 PM | 18M0W7D | |
| 24E | 1852.5 - 1907.5 | 0.3027 | 2.5 PM | 4M52W7D | |
| 27 | 1720.0 - 1745.0 | 0.2624 | 2.5 PM | 18M0G7D | |
| 27 | 1711.5 - 1753.5 | 0.2864 | 2.5 PM | 2M70G7D | |
| 27 | 1720.0 - 1745.0 | 0.2208 | 2.5 PM | 18M0W7D | |
| 27 | 1712.5 - 1752.5 | 0.2399 | 2.5 PM | 4M51W7D | |
| 22H | 829.0 - 844.0 | 0.2065 | 2.5 PM | 9M03G7D | |
| 22H | 826.5 - 846.5 | 0.2173 | 2.5 PM | 4M52G7D | |
| 22H | 829.0 - 844.0 | 0.177 | 2.5 PM | 9M02W7D | |
| 22H | 826.5 - 846.5 | 0.1871 | 2.5 PM | 4M51W7D | |
| 27 | 704.0 - 711.0 | 0.1849 | 2.5 PM | 9M07G7D | |
| 27 | 700.5 - 714.5 | 0.1892 | 2.5 PM | 2M70G7D | |
| 27 | 704.0 - 711.0 | 0.1589 | 2.5 PM | 9M07W7D | |
| 27 | 701.5 - 713.5 | 0.1722 | 2.5 PM | 4M52W7D | |
| 27 | 709.0 - 711.0 | 0.1858 | 2.5 PM | 8M96G7D | |
| 27 | 706.5 - 713.5 | 0.1871 | 2.5 PM | 4M55G7D | |
| 27 | 709.0 - 711.0 | 0.16 | 2.5 PM | 8M92W7D | |
| 27 | 706.5 - 713.5 | 0.171 | 2.5 PM | 4M56W7D | |
| 27 | 1720.0 - 1770.0 | 0.2333 | 2.5 PM | 18M2G7D | |
| 27 | 1711.5 - 1778.5 | 0.2506 | 2.5 PM | 2M70G7D | |
| 27 | 1720.0 - 1770.0 | 0.1945 | 2.5 PM | 18M2W7D | |
| 27 | 1711.5 - 1778.5 | 0.2042 | 2.5 PM | 2M70W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.91W/kg and 1.43W/kg respectively |
TCB Grant - Application NtxT5Dns52BBeAAdRoa8+w==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 11/19/2025 Application Dated: 11/19/2025 |
| MedMinder Systems, Inc. |
| 320 Norwood Park South |
| Norwood, MA 02062 |
| Attention: Russell Reier , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AAWH-PILLBOXURI1 |
| Name of Grantee: | MedMinder Systems, Inc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | MedMinder Uri 1 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0058 |
| Power listed is the maximum conducted output power. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application MKBXBRou1L3VUIAMM1Oj2g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 11/19/2025 Application Dated: 11/19/2025 |
| MedMinder Systems, Inc. |
| 320 Norwood Park South |
| Norwood, MA 02062 |
| Attention: Russell Reier , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AAWH-PILLBOXURI1 |
| Name of Grantee: | MedMinder Systems, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | MedMinder Uri 1 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0038 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.0537 |
| Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.35W/kg and 1.26W/kg respectively |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application Im4enEUE4rjMxilSC9G7UA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 11/19/2025 Application Dated: 11/19/2025 |
| MedMinder Systems, Inc. |
| 320 Norwood Park South |
| Norwood, MA 02062 |
| Attention: Russell Reier , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AAWH-PILLBOXURI1 |
| Name of Grantee: | MedMinder Systems, Inc. |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | MedMinder Uri 1 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application AqMPjqSTRvv6TR10kUYQkA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 11/19/2025 Application Dated: 11/19/2025 |
| MedMinder Systems, Inc. |
| 320 Norwood Park South |
| Norwood, MA 02062 |
| Attention: Russell Reier , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AAWH-PILLBOXURI1 |
| Name of Grantee: | MedMinder Systems, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | MedMinder Uri 1 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0097 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.0105 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.0121 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.0123 |
| Power listed is the maximum conducted output power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.52W/kg and 1.43W/kg respectively |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |