FCC ID 2AAZ7-SW100

Medical Alert Device

by SNPowercom Co. Ltd.

Grantee Code: 2AAZ7   Product Code: SW100
Latest application date: 2015-07-28

FCC ID Device Details

FCC ID2AAZ7-SW100
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AAZ7
Product CodeSW100
Applicant BusinessSNPowercom Co. Ltd. 🇰🇷
Related Domains snpowercom.com
Equipment ClassMedical Alert Device
Test FirmHCT Co., LTD

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
13.56 MHzOriginal Equipment2015-07-28
824.7-848.31 MHzOriginal Equipment2015-07-28
2402-2480 MHzOriginal Equipment2015-07-28

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2016-01-24PDF 597.1 KB
Internal PhotosInternal Photos2016-01-24PDF 1.1 MB
External PhotosExternal Photos2016-01-24PDF 551.9 KB
ID Label and Location InfoID Label/Location Info2015-07-28PDF 40.6 KB
Test Setup PhotosTest Setup Photos2016-01-24PDF 2.2 MB
Test Setup Photos_RFTest Setup Photos2016-01-24PDF 1.2 MB
Test Setup Photos_SARTest Setup Photos2016-01-24PDF 212.8 KB
RF Test Report_BLETest Report2015-07-28PDF 2.4 MB
RF Test Report_NFCTest Report2015-07-28PDF 2.3 MB
RF Test Report_Part 22_24Test Report2015-07-28PDF 1.4 MB
SAR Test ReportRF Exposure Info2015-07-28PDF 3 MB
Test Report Metadata onlyTest Report2015-07-28PDF 3.5 MB
Confidential Request LetterCover Letter(s)2015-07-28PDF 206.7 KB
POA letterCover Letter(s)2015-07-28PDF 36 KB
Block Diagram Metadata onlyBlock DiagramPDF 351.7 KB
Schematics Metadata onlySchematicsPDF 768.5 KB
Operational Description Metadata onlyOperational DescriptionPDF 280.5 KB
Operational Description Metadata onlyOperational DescriptionPDF 190 KB
Part List Metadata onlyParts List/Tune Up InfoPDF 173.7 KB
Tune Up Info Metadata onlyParts List/Tune Up InfoPDF 148.1 KB

Application Information

Application IDuMwcplQ3J8TQRWeG88OGqQ==
Final Action Date2015-07-28
Application PurposeOriginal Equipment
Applicant FRN0022972681
ModelSW100
Frequency Range13.56 MHz
Equipment ClassDXX - Part 15 Low Power Communication Device Transmitter
Device DescriptionMedical Alert Device
Responsible PartySteve Jung, Director, steve.jung@snpowercom.com , +82-70-4918-6121
Test FirmSang Lee, HCT Co., LTD, sjlee@HCT.co.kr , 82-31-645-6420
TCB Emailtcb@hctamerica.com
TCB ScopeA1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
Short-Term ConfidentialityYes
Short-Term Confidentiality Date01/24/2016
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
uMwcplQ3J8TQRWeG88OGqQ==2015-07-28Original Equipment
Q6fYe+Zzvm6j5Nk3ns2P8g==2015-07-28Original Equipment
GLPnvqaOXWWZt/HmdDF1LA==2015-07-28Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
13.56 MHz15CCC
824.7-848.31 MHz0.0462.5ppm1M26F9W22H
1851.25-1908.75 MHz0.2442.5ppm1M26F9W24E
2402-2480 MHz0.002700015CCC

Grants

TCB Grant - Application uMwcplQ3J8TQRWeG88OGqQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  HCT America LLC
1726 Ringwood Avenue
San Jose, CA 95131
Date of Grant: 07/28/2015

Application Dated: 07/28/2015
SNPowercom Co. Ltd.
5th floor, Elentec building, Pangyo Seven Venture
Valley2, 17, Pangyo-ro 228beon-gil, Bundang-gu,
Seongam-si, Gyeonggi-do,, 431-815
South Korea
 
Attention: Steve Jung , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAZ7-SW100
Name of Grantee:  SNPowercom Co. Ltd.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Medical Alert Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application uMwcplQ3J8TQRWeG88OGqQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SNPowercom Co. Ltd.
5th floor, Elentec building, Pangyo Seven Venture Valley2, 17, Pangyo-ro 228beon-gil, Bundang-gu,
Seongam-si, Gyeonggi-do,, 431-815
South Korea
  Date of Grant: 07/28/2015

Application Dated: 07/28/2015
 
Attention: Steve Jung , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAZ7-SW100
Name of Grantee:  SNPowercom Co. Ltd.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Medical Alert Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application Q6fYe+Zzvm6j5Nk3ns2P8g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  HCT America LLC
1726 Ringwood Avenue
San Jose, CA 95131
Date of Grant: 07/28/2015

Application Dated: 07/28/2015
SNPowercom Co. Ltd.
5th floor, Elentec building, Pangyo Seven Venture
Valley2, 17, Pangyo-ro 228beon-gil, Bundang-gu,
Seongam-si, Gyeonggi-do,, 431-815
South Korea
 
Attention: Steve Jung , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAZ7-SW100
Name of Grantee:  SNPowercom Co. Ltd.
Equipment Class: PCS Licensed Transmitter worn on body
Notes: Medical Alert Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.046 2.5  PM 1M26F9W
24E 1851.25  -  1908.75 0.244 2.5  PM 1M26F9W

Power listed is ERP for Part 22 and EIRP for Part 24. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head and body exposure conditions are 0.93 W/kg and 1.41 W/kg, respectively.

EAS Grant - Application Q6fYe+Zzvm6j5Nk3ns2P8g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SNPowercom Co. Ltd.
5th floor, Elentec building, Pangyo Seven Venture Valley2, 17, Pangyo-ro 228beon-gil, Bundang-gu,
Seongam-si, Gyeonggi-do,, 431-815
South Korea
  Date of Grant: 07/28/2015

Application Dated: 07/28/2015
 
Attention: Steve Jung , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAZ7-SW100
Name of Grantee:  SNPowercom Co. Ltd.
Equipment Class: PCS Licensed Transmitter worn on body
Notes: Medical Alert Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.046 2.5  PM 1M26F9W
24E 1851.25  -  1908.75 0.244 2.5  PM 1M26F9W

Power listed is ERP for Part 22 and EIRP for Part 24. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head and body exposure conditions are 0.93 W/kg and 1.41 W/kg, respectively.



TCB Grant - Application GLPnvqaOXWWZt/HmdDF1LA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  HCT America LLC
1726 Ringwood Avenue
San Jose, CA 95131
Date of Grant: 07/28/2015

Application Dated: 07/28/2015
SNPowercom Co. Ltd.
5th floor, Elentec building, Pangyo Seven Venture
Valley2, 17, Pangyo-ro 228beon-gil, Bundang-gu,
Seongam-si, Gyeonggi-do,, 431-815
South Korea
 
Attention: Steve Jung , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAZ7-SW100
Name of Grantee:  SNPowercom Co. Ltd.
Equipment Class: Digital Transmission System
Notes: Medical Alert Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0027  

Power output listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body worn operating requirements for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application GLPnvqaOXWWZt/HmdDF1LA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SNPowercom Co. Ltd.
5th floor, Elentec building, Pangyo Seven Venture Valley2, 17, Pangyo-ro 228beon-gil, Bundang-gu,
Seongam-si, Gyeonggi-do,, 431-815
South Korea
  Date of Grant: 07/28/2015

Application Dated: 07/28/2015
 
Attention: Steve Jung , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AAZ7-SW100
Name of Grantee:  SNPowercom Co. Ltd.
Equipment Class: Digital Transmission System
Notes: Medical Alert Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0027  

Power output listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body worn operating requirements for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: