FCC ID 2AB73-V6
Smart Health Bracelet
by Joint Chinese Ltd
Grantee Code: 2AB73 Product Code: V6
Latest application date: 2025-09-30
FCC ID Device Details
| FCC ID | 2AB73-V6 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AB73 |
| Product Code | V6 |
| Applicant Business | Joint Chinese Ltd 🇨🇳 |
| Related Domains | |
| Equipment Class | Smart Health Bracelet |
| Test Firm | SHENZHEN STS TEST SERVICES CO.,LTD. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1860-1905 MHz | Original Equipment | 2025-09-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2025-09-30 | PDF 3.2 MB |
| Internal photos | Internal Photos | 2025-09-30 | PDF 2.8 MB |
| External photos | External Photos | 2025-09-30 | PDF 1.6 MB |
| ID label and location | ID Label/Location Info | 2025-09-30 | PDF 34.8 KB |
| Test Setup photo | Test Setup Photos | 2025-09-30 | PDF 551.5 KB |
| Test Setup photo SAR | Test Setup Photos | 2025-09-30 | PDF 175.5 KB |
| Test report NB-IoT | Test Report | 2025-09-30 | PDF 1.7 MB |
| Test report NB-IoT Appendix part1 | Test Report | 2025-09-30 | PDF 5.9 MB |
| Test report NB-IoT Appendix part2 | Test Report | 2025-09-30 | PDF 4.7 MB |
| Test report NB-IoT Appendix part3 | Test Report | 2025-09-30 | PDF 5.4 MB |
| Test report NB-IoT Appendix part4 | Test Report | 2025-09-30 | PDF 5 MB |
| Test report NB-IoT Appendix part5 | Test Report | 2025-09-30 | PDF 4.6 MB |
| Test report NB-IoT Appendix part6 | Test Report | 2025-09-30 | PDF 5.3 MB |
| Test report eMTC | Test Report | 2025-09-30 | PDF 2.2 MB |
| Test report eMTC Appendix part1 | Test Report | 2025-09-30 | PDF 4.7 MB |
| Test report eMTC Appendix part2 | Test Report | 2025-09-30 | PDF 3 MB |
| Test report eMTC Appendix part3 | Test Report | 2025-09-30 | PDF 5.8 MB |
| Test report eMTC Appendix part4 | Test Report | 2025-09-30 | PDF 5.6 MB |
| Test report eMTC Appendix part5 | Test Report | 2025-09-30 | PDF 5.6 MB |
| Test report eMTC Appendix part6 | Test Report | 2025-09-30 | PDF 5.8 MB |
| Attestation_Statement | Attestation Statements | 2025-09-30 | PDF 172.2 KB |
| Kaspersky Statement | Attestation Statements | 2025-09-30 | PDF 285.1 KB |
| RF function Declaration | Attestation Statements | 2025-09-30 | PDF 74.9 KB |
| TCB_validation_US_agent_process | Attestation Statements | 2025-09-30 | PDF 551.8 KB |
| US_Agent | Attestation Statements | 2025-09-30 | PDF 67.1 KB |
| Confidentiality | Cover Letter(s) | 2025-09-30 | PDF 173.9 KB |
| Letter Authorization | Cover Letter(s) | 2025-09-30 | PDF 119.6 KB |
| RF Exposure SAR | RF Exposure Info | 2025-09-30 | PDF 4.2 MB |
| RF Exposure SAR Calibration part1 | RF Exposure Info | 2025-09-30 | PDF 4.5 MB |
| RF Exposure SAR Calibration part2 | RF Exposure Info | 2025-09-30 | PDF 4.3 MB |
| RF Exposure SAR Dipole | RF Exposure Info | 2025-09-30 | PDF 193.5 KB |
| Block Diagram Metadata only | Block Diagram | PDF 75.3 KB | |
| Schematics Metadata only | Schematics | PDF 112.2 KB | |
| Operational Description Metadata only | Operational Description | PDF 788.4 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 295.4 KB | |
| Tune Up Metadata only | Parts List/Tune Up Info | PDF 95.2 KB |
Application Information
| Application ID | 8zDqsym8a42UVhcJ3kKUdw== |
|---|---|
| Final Action Date | 2025-09-30 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0023528003 |
| Model | V6 |
| Frequency Range | 1860-1905 MHz |
| Equipment Class | PCT - PCS Licensed Transmitter worn on body |
| Device Description | Smart Health Bracelet |
| Responsible Party | Kathy Zhao, admin@jointcorp.com |
| Technical Contact | Leon run Chen, Shenzhen Microtest Co., Ltd, leon@51mti.com |
| Test Firm | Bovey Yang, SHENZHEN STS TEST SERVICES CO.,LTD., Bovey@stsapp.com |
| TCB Email | elabscert@applus.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 8zDqsym8a42UVhcJ3kKUdw== | 2025-09-30 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 1850.2-1909.8 MHz | 0.18707 | 0.019 PM | 188KG7D | 24E |
| 1852.5-1907.5 MHz | 0.24155 | 0.019 PM | 1M11G7D | 24E |
| 1860-1900 MHz | 0.22284 | 0.019 PM | 1M13G7D | 24E |
| 1852.5-1907.5 MHz | 0.25177 | 0.019 PM | 930KW7D | 24E |
| 1860-1900 MHz | 0.22961 | 0.019 PM | 966KW7D | 24E |
| 1710.2-1754.8 MHz | 0.15776 | 0.019 PM | 189KG7D | 27 |
| 1711.5-1753.5 MHz | 0.14125 | 0.021 PM | 1M10G7D | 27 |
| 1720-1745 MHz | 0.1349 | 0.021 PM | 1M13G7D | 27 |
| 1711.5-1753.5 MHz | 0.14588 | 0.021 PM | 934KW7D | 27 |
| 1720-1745 MHz | 0.13213 | 0.021 PM | 967KW7D | 27 |
| 1850.2-1914.8 MHz | 0.1875 | 0.019 PM | 190KG7D | 24E |
| 1852.5-1912.5 MHz | 0.19364 | 0.019 PM | 1M11G7D | 24E |
| 1860-1905 MHz | 0.18072 | 0.019 PM | 1M13G7D | 24E |
| 1860-1905 MHz | 0.20137 | 0.019 PM | 975KW7D | 24E |
| 1710.2-1779.8 MHz | 0.15812 | 0.019 PM | 352KG7D | 27 |
| 1717.5-1772.5 MHz | 0.12912 | 0.021 PM | 1M13G7D | 27 |
| 1720-1770 MHz | 0.11967 | 0.021 PM | 1M13G7D | 27 |
| 1717.5-1772.5 MHz | 0.12618 | 0.021 PM | 958KW7D | 27 |
| 1720-1770 MHz | 0.12303 | 0.021 PM | 971KW7D | 27 |
Grants
TCB Grant - Application 8zDqsym8a42UVhcJ3kKUdw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 09/30/2025 Application Dated: 09/30/2025 |
| Joint Chinese Ltd |
| Building 6, Huafeng Tech Park, |
| Luotian Industrial Area, Songgang Town, Baoan |
| Shenzhen, 518125 China |
| Attention: Kathy Zhao , Export Sales Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AB73-V6 |
| Name of Grantee: | Joint Chinese Ltd |
| Equipment Class: | PCS Licensed Transmitter worn on body |
| Notes: | Smart Health Bracelet |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.2 - 1909.8 | 0.18707 | 0.019 PM | 188KG7D | |
| 24E | 1852.5 - 1907.5 | 0.24155 | 0.019 PM | 1M11G7D | |
| 24E | 1860.0 - 1900.0 | 0.22284 | 0.019 PM | 1M13G7D | |
| 24E | 1852.5 - 1907.5 | 0.25177 | 0.019 PM | 930KW7D | |
| 24E | 1860.0 - 1900.0 | 0.22961 | 0.019 PM | 966KW7D | |
| 27 | 1710.2 - 1754.8 | 0.15776 | 0.019 PM | 189KG7D | |
| 27 | 1711.5 - 1753.5 | 0.14125 | 0.021 PM | 1M10G7D | |
| 27 | 1720.0 - 1745.0 | 0.1349 | 0.021 PM | 1M13G7D | |
| 27 | 1711.5 - 1753.5 | 0.14588 | 0.021 PM | 934KW7D | |
| 27 | 1720.0 - 1745.0 | 0.13213 | 0.021 PM | 967KW7D | |
| 24E | 1850.2 - 1914.8 | 0.1875 | 0.019 PM | 190KG7D | |
| 24E | 1852.5 - 1912.5 | 0.19364 | 0.019 PM | 1M11G7D | |
| 24E | 1860.0 - 1905.0 | 0.18072 | 0.019 PM | 1M13G7D | |
| 24E | 1860.0 - 1905.0 | 0.20137 | 0.019 PM | 975KW7D | |
| 27 | 1710.2 - 1779.8 | 0.15812 | 0.019 PM | 352KG7D | |
| 27 | 1717.5 - 1772.5 | 0.12912 | 0.021 PM | 1M13G7D | |
| 27 | 1720.0 - 1770.0 | 0.11967 | 0.021 PM | 1M13G7D | |
| 27 | 1717.5 - 1772.5 | 0.12618 | 0.021 PM | 958KW7D | |
| 27 | 1720.0 - 1770.0 | 0.12303 | 0.021 PM | 971KW7D |
| Output power listed is ERP for frequencies below 1 GHz and EIRP for frequencies above 1 GHz. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for front of face Limit is 1.6 W/kg@1g and Wrist is 4.0W/kg@10g. Device types have also been tested against this SAR limit. The evaluation distance for product specific (front of face) and extremity (wrist) is 10 mm and 0 mm separately. The highest reported SAR for product specific (front of face) and extremity (wrist) use conditions is 0.43 W/kg and 0.36 W/kg, respectively. This device supports Cat-M of 1.4, 3, 5, 10, 15 and 20MHz Bandwidth modes for all Bands; This device supports NB-IoT of 3.75 and 15 kHz subcarrier space for all Bands; |