FCC ID 2AB7K-T9201

BodySense Blood Pressure Monitor

by Anker Technology Co., Limited

Grantee Code: 2AB7K   Product Code: T9201
Latest application date: 2017-05-22

Device Images

FCC ID Device Details

FCC ID2AB7K-T9201
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AB7K
Product CodeT9201
Applicant BusinessAnker Technology Co., Limited
Related Domains oceanwing.com
Equipment ClassBodySense Blood Pressure Monitor
Test FirmShenzhen NTEK Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2017-05-22
2402-2480 MHzOriginal Equipment2016-12-02

Exhibits

DocumentTypeAvailableFile
Users manualUsers Manual2017-05-22PDF 1.6 MB
Internal PhotosInternal Photos2017-05-22PDF 1.4 MB
Internal photosInternal Photos2016-12-02PDF 971.6 KB
External PhotosExternal Photos2017-05-22PDF 740.6 KB
External photosExternal Photos2016-12-02PDF 609.9 KB
LabelID Label/Location Info2017-05-22PDF 95.7 KB
Test Setup PhotosTest Setup Photos2017-05-22PDF 279.3 KB
Test setup photosTest Setup Photos2016-12-02PDF 247.6 KB
Test ReportTest Report2017-05-22PDF 857.7 KB
Test reportTest Report2016-12-02PDF 914.1 KB
Authorization LetterCover Letter(s)2017-05-22PDF 12.7 KB
Class II permissive change letterCover Letter(s)2017-05-22PDF 20.2 KB
Confidentiality requestCover Letter(s)2017-05-22PDF 23.5 KB
Authorization letterCover Letter(s)2016-12-02PDF 13.3 KB
RF exposure calculationRF Exposure Info2017-05-22PDF 45.2 KB
RF Exposure ReportRF Exposure Info2016-12-02PDF 25.8 KB
Block Diagram Metadata onlyBlock DiagramPDF 171 KB
Block Diagram Metadata onlyBlock DiagramPDF 115.9 KB
Schematics Metadata onlySchematicsPDF 230.9 KB
Schematics Metadata onlySchematicsPDF 105.6 KB
BLE specifications Metadata onlyOperational DescriptionPDF 527.9 KB
Operational Description Metadata onlyOperational DescriptionPDF 180.6 KB
Operational Description Metadata onlyOperational DescriptionPDF 122.2 KB

Application Information

Application ID0fiwqywAvJjSs4nKwt3ZrQ==
Final Action Date2017-05-22
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0023521370
ModelT9201
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionBodySense Blood Pressure Monitor
Responsible PartySimon Zhang, Product Manager, simon.zhang@oceanwing.com , 0731-88709535
Technical ContactJason Chen, Shenzhen NTEK Testing Technology Co., Ltd., jason_chen@ntek.org.cn , 86-755-61156588
Test FirmJason Chen, Shenzhen NTEK Testing Technology Co., Ltd., jason.chen@ntek.org.cn , (86)-0755-61156588
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is Conducted.

Applications

Application IDDatePurpose
0fiwqywAvJjSs4nKwt3ZrQ==2017-05-22Class II permissive change or modification of presently authorized equipment
GXVhnBN7z85U4XiNpGq2/g==2016-12-02Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.000300015C20
2402-2480 MHz0.000200015C20

Grants

TCB Grant - Application GXVhnBN7z85U4XiNpGq2/g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 12/02/2016

Application Dated: 12/02/2016
Anker Technology Co., Limited
Room 1318-19, Hollywood Plaza,
610 Nathan Road, Mongkok,
Kowloon,
Hong Kong
 
Attention: Simon Zhang , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AB7K-T9201
Name of Grantee:  Anker Technology Co., Limited
Equipment Class: Digital Transmission System
Notes: BodySense Blood Pressure Monitor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2402.0  -  2480.0 0.0002  

Power Output listed is Conducted.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application GXVhnBN7z85U4XiNpGq2/g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Anker Technology Co., Limited
Room 1318-19, Hollywood Plaza, 610 Nathan Road, Mongkok,
Kowloon,
Hong Kong
  Date of Grant: 12/02/2016

Application Dated: 12/02/2016
 
Attention: Simon Zhang , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AB7K-T9201
Name of Grantee:  Anker Technology Co., Limited
Equipment Class: Digital Transmission System
Notes: BodySense Blood Pressure Monitor
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2402.0  -  2480.0 0.0002  

Power Output listed is Conducted.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

TCB Grant - Application 0fiwqywAvJjSs4nKwt3ZrQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 05/22/2017

Application Dated: 05/22/2017
Anker Technology Co., Limited
Room 1318-19, Hollywood Plaza,
610 Nathan Road, Mongkok,
Kowloon,
Hong Kong
 
Attention: Simon Zhang , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AB7K-T9201
Name of Grantee:  Anker Technology Co., Limited
Equipment Class: Digital Transmission System
Notes: BodySense Blood Pressure Monitor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2402.0  -  2480.0 0.0003  

Power output listed is Conducted.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application 0fiwqywAvJjSs4nKwt3ZrQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Anker Technology Co., Limited
Room 1318-19, Hollywood Plaza, 610 Nathan Road, Mongkok,
Kowloon,
Hong Kong
  Date of Grant: 05/22/2017

Application Dated: 05/22/2017
 
Attention: Simon Zhang , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AB7K-T9201
Name of Grantee:  Anker Technology Co., Limited
Equipment Class: Digital Transmission System
Notes: BodySense Blood Pressure Monitor
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2402.0  -  2480.0 0.0003  

Power output listed is Conducted.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

Mail To: