FCC ID 2ABOGCMS50SP

Pulse Oximiter

by Contec Medical Systems Co., Ltd.

Grantee Code: 2ABOG   Product Code: CMS50SP
Latest application date: 2025-06-26

FCC ID Device Details

FCC ID2ABOGCMS50SP
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ABOG
Product CodeCMS50SP
Applicant BusinessContec Medical Systems Co., Ltd. 🇨🇳
Equipment ClassPulse Oximiter
Test FirmCCIC Southern Testing Co., Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2025-06-26

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2025-06-26PDF 498 KB
User manualUsers Manual2025-06-26PDF 498 KB
Internal PhotosInternal Photos2025-06-26PDF 1.4 MB
Internal photosInternal Photos2025-06-26PDF 1.4 MB
External PhotosExternal Photos2025-06-26PDF 982.8 KB
External photosExternal Photos2025-06-26PDF 982.8 KB
Label and locationID Label/Location Info2025-06-26PDF 385.3 KB
Test Setup photoTest Setup Photos2025-06-26PDF 559.7 KB
Test photosTest Setup Photos2025-06-26PDF 386.3 KB
Antenna specificationTest Report2025-06-26PDF 313.6 KB
BLE ReportTest Report2025-06-26PDF 3.2 MB
Part 15 B EMC ReportTest Report2025-06-26PDF 945.9 KB
2.911 (d)(5)(i)CertificationEquipmentTypev1.2Attestation Statements2025-06-26PDF 84.9 KB
2.911 (d)(5)(ii)CertificationApplicantv1.3Attestation Statements2025-06-26PDF 166.2 KB
2.911 (d)(5)(ii)CertificiationApplicantv1.2Attestation Statements2025-06-26PDF 166.2 KB
2.911 (d)(7)USAgentforServiceofProcessv1.3Attestation Statements2025-06-26PDF 110.5 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2025-06-26PDF 98.6 KB
Letter of Authorization Rev 1.0Cover Letter(s)2025-06-26PDF 20.9 KB
Letter of Authorization Rev2.0Cover Letter(s)2025-06-26PDF 20.9 KB
Model DifferenceCover Letter(s)2025-06-26PDF 54.5 KB
Model Difference DeclarationCover Letter(s)2025-06-26PDF 54.5 KB
MPERF Exposure Info2025-06-26PDF 283.2 KB
Block Diagram Metadata onlyBlock DiagramPDF 102.1 KB
SCH Metadata onlySchematicsPDF 152.4 KB
Operation Description Metadata onlyOperational DescriptionPDF 197.3 KB

Application Information

Application IDNf7kv2/6XvCacolF4+628A==
Final Action Date2025-06-26
Application PurposeOriginal Equipment
Applicant FRN0023248982
ModelCMS50SP
Equipment ClassJAB - Part 15 Class B Digital Device
Device DescriptionPulse Oximiter
Responsible PartyXueyong LI, lxy1011@163.com , 863358015490
Technical ContactContec Medical Systems Co., Ltd., lxy1011@163.com
Test FirmChris You, CCIC Southern Testing Co., Ltd, youxj@ccic-set.com , 86-0755-86131239
TCB Emailcertification@micomlabs.com
TCB ScopeA1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
Nf7kv2/6XvCacolF4+628A==2025-06-26Original Equipment
Gsy/LsmSVnWPTNY2m8rIcw==2025-06-26Original Equipment

Equipment Authorization

FrequencyOutputGrant Notes
CC
2402-2480 MHz0.0026000CC

Grants

TCB Grant - Application Nf7kv2/6XvCacolF4+628A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 06/26/2025

Application Dated: 06/26/2025
Contec Medical Systems Co., Ltd.
No. 112 Qinhuang West Street
Economic &Technical Development Zone
Qinhuangdao,
China
 
Attention: Xueyong LI ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ABOGCMS50SP
Name of Grantee:  Contec Medical Systems Co., Ltd.
Equipment Class: Part 15 Class B Digital Device
Notes: Pulse Oximiter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application Gsy/LsmSVnWPTNY2m8rIcw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 06/26/2025

Application Dated: 06/26/2025
Contec Medical Systems Co., Ltd.
No. 112 Qinhuang West Street
Economic &Technical Development Zone
Qinhuangdao,
China
 
Attention: Xueyong LI ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ABOGCMS50SP
Name of Grantee:  Contec Medical Systems Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Pulse Oximiter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0026  

Power listed is the maximum conducted output power.

CC: This device is certified pursuant to two different Part 15 rules sections.