FCC ID 2ABRUBDRFM204

BDE Sub-1G Module

by Guangzhou BDE Technology Inc.

Grantee Code: 2ABRU   Product Code: BDRFM204
Latest application date: 2018-09-27

FCC ID Device Details

FCC ID2ABRUBDRFM204
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ABRU
Product CodeBDRFM204
Applicant BusinessGuangzhou BDE Technology Inc. 🇨🇳
Related Domains bdecomm.com
Equipment ClassBDE Sub-1G Module
Test FirmUL Verification Services (Guangzhou) Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
903-927 MHzOriginal Equipment2018-09-27

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2018-09-27PDF 1.6 MB
Internal PhotosInternal Photos2018-09-27PDF 138.4 KB
External PhotosExternal Photos2018-09-27PDF 109.4 KB
label and Label LocationID Label/Location Info2018-09-27PDF 379.5 KB
Setup PhotosTest Setup Photos2018-09-27PDF 1.5 MB
Test ReportTest Report2018-09-27PDF 1.8 MB
Declaration LetterCover Letter(s)2018-09-27PDF 117 KB
FCC Authorization LetterCover Letter(s)2018-09-27PDF 133.2 KB
FCC Confidentiality Request LetterCover Letter(s)2018-09-27PDF 79.5 KB
RF Exposure ReportRF Exposure Info2018-09-27PDF 116.1 KB
Block Diagram Metadata onlyBlock DiagramPDF 168.6 KB
Circuit Diagram Metadata onlySchematicsPDF 9.6 KB
Operational Description Metadata onlyOperational DescriptionPDF 51.6 KB

Application Information

Application IDHeUbd51ryYD0SRtzj6omtA==
Final Action Date2018-09-27
Application PurposeOriginal Equipment
Applicant FRN0023079460
ModelBDRFM204
Frequency Range903-927 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionBDE Sub-1G Module
Responsible PartyJacky Tian, info@bdecomm.com , (+86)15011900258
Test FirmStephen Guo, UL Verification Services (Guangzhou) Co., Ltd., Stephen.guo@ul.com , +86 0769 33817120
TCB EmailLST.FRE.CertNotice@ul.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsListed output power is peak conducted. This module is only installed by OEM or OEM integrator in the specific host or a group of similar host specified in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. OEM integrator must be provided with installation instructions and transmitter operating condition for satisfying RF exposure compliance. The Grantee is responsible for providing the documentation required for modular use. The responsibility for the use of this module, in all configurations utilized or contemplated, remains with the Grantee.

Applications

Application IDDatePurpose
HeUbd51ryYD0SRtzj6omtA==2018-09-27Original Equipment

Equipment Authorization

FrequencyOutputRules
903-927 MHz0.011600015C

Grants

TCB Grant - Application HeUbd51ryYD0SRtzj6omtA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 09/27/2018

Application Dated: 09/27/2018
Guangzhou BDE Technology Inc.
B2-403, Chuangyi Building
162 Science Avenue, Huangpu District
Guangzhou, 510663
China
 
Attention: Jacky Tian

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ABRUBDRFM204
Name of Grantee:  Guangzhou BDE Technology Inc.
Equipment Class: Digital Transmission System
Notes: BDE Sub-1G Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 903.0  -  927.0 0.0116  

Listed output power is peak conducted.

This module is only installed by OEM or OEM integrator in the specific host or a group of similar host specified in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. OEM integrator must be provided with installation instructions and transmitter operating condition for satisfying RF exposure compliance. The Grantee is responsible for providing the documentation required for modular use. The responsibility for the use of this module, in all configurations utilized or contemplated, remains with the Grantee.


EAS Grant - Application HeUbd51ryYD0SRtzj6omtA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Guangzhou BDE Technology Inc.
B2-403, Chuangyi Building 162 Science Avenue, Huangpu District
Guangzhou, 510663
China
  Date of Grant: 09/27/2018

Application Dated: 09/27/2018
 
Attention: Jacky Tian

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ABRUBDRFM204
Name of Grantee:  Guangzhou BDE Technology Inc.
Equipment Class: Digital Transmission System
Notes: BDE Sub-1G Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 903.0  -  927.0 0.0116  

Listed output power is peak conducted.

This module is only installed by OEM or OEM integrator in the specific host or a group of similar host specified in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. OEM integrator must be provided with installation instructions and transmitter operating condition for satisfying RF exposure compliance. The Grantee is responsible for providing the documentation required for modular use. The responsibility for the use of this module, in all configurations utilized or contemplated, remains with the Grantee.



Mail To: