FCC ID 2ABTW-FK-POS5M

Flexkom POS

by FlexKom Technology Asia Limited

Grantee Code: 2ABTW   Product Code: FKPOS5M
Latest application date: 2014-08-07

FCC ID Device Details

FCC ID2ABTW-FK-POS5M
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ABTW
Product CodeFKPOS5M
Applicant BusinessFlexKom Technology Asia Limited
Related Domains flexkom.com
Equipment ClassFlexkom POS
Test FirmShenzhen Toby Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2014-08-07
824.2-848.8 MHzOriginal Equipment2014-08-07
2412-2462 MHzOriginal Equipment2014-08-07

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2014-08-07PDF 1.4 MB
IntInternal Photos2014-08-07PDF 848.2 KB
ExtExternal Photos2014-08-07PDF 433.2 KB
LabelID Label/Location Info2014-08-07PDF 70.1 KB
Model DifferenceID Label/Location Info2014-08-07PDF 14.5 KB
Model DifferencesID Label/Location Info2014-08-07PDF 14.5 KB
PCE SetupTest Setup Photos2014-08-07PDF 311.5 KB
SetupTest Setup Photos2014-08-07PDF 431.7 KB
SetupTest Setup Photos2014-08-07PDF 432.2 KB
DSSTest Report2014-08-07PDF 1.3 MB
DTSTest Report2014-08-07PDF 1.2 MB
PCETest Report2014-08-07PDF 2.1 MB
Setup Metadata onlyTest Report2014-08-07PDF 431.7 KB
AuthorizationCover Letter(s)2014-08-07PDF 98.3 KB
ConfidCover Letter(s)2014-08-07PDF 127.4 KB
DofCCover Letter(s)2014-08-07PDF 131.8 KB
LabelRF Exposure Info2014-08-07PDF 70.1 KB
SARRF Exposure Info2014-08-07PDF 3.9 MB
Block Metadata onlyBlock DiagramPDF 42.4 KB
Schema Metadata onlySchematicsPDF 976.2 KB
Ops Metadata onlyOperational DescriptionPDF 405.1 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 57.2 KB
Power Table Metadata onlyParts List/Tune Up InfoPDF 52.4 KB
Tune Up Metadata onlyParts List/Tune Up InfoPDF 109.8 KB

Application Information

Application IDgGsAKgF8wlJJZVu1Afw6QQ==
Final Action Date2014-08-07
Application PurposeOriginal Equipment
Applicant FRN0023347610
ModelFK-POS5M
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionFlexkom POS
Responsible PartyPETER Gruenewald, p.gruenewald@flexkom.com , +49 15253542629
Technical ContactMark Koop, Teleconformity, mark.koop@teleconformity.com , (31)848395876
Test FirmJustin Zhang, Shenzhen Toby Technology Co., Ltd., toby888@tongbiao.com , 0086-755-26509301
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is Conducted. This device may transmit simultaneously with other Licensed and Unlicensed transmitters. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
gGsAKgF8wlJJZVu1Afw6QQ==2014-08-07Original Equipment
bk34+2CTX8kzdjWqjdA/0Q==2014-08-07Original Equipment
Y/x9kLDLxNvbWWlRTw5riQ==2014-08-07Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.2-848.8 MHz1.1040.07ppm248KGXW22HBC
824.2-848.8 MHz0.7740.05ppm245KG7W22HBC
826.4-846.6 MHz0.1550.06ppm4M21F9W22HBC
1850.2-1909.8 MHz0.7150.04ppm249KGXW24EBC
1850.2-1909.8 MHz0.7550.03ppm249KG7W24EBC
1852.4-1907.6 MHz0.1230.04ppm4M18F9W24EBC
2402-2480 MHz0.002280015CCC
2412-2462 MHz0.017115CCC
2422-2452 MHz0.010815CCC

Grants

TCB Grant - Application Y/x9kLDLxNvbWWlRTw5riQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/07/2014

Application Dated: 08/07/2014
FlexKom Technology Asia Limited
Unit B,11 Floor, Silvercorp International Tower
707-713,Nathan Road
KowLoon,
Hong Kong
 
Attention: PETER Gruenewald

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ABTW-FK-POS5M
Name of Grantee:  FlexKom Technology Asia Limited
Equipment Class: Digital Transmission System
Notes: Flexkom POS
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0171  
CC 15C 2422.0  -  2452.0 0.0108  

Power Output listed is Conducted. This device is approved for simultaneous transmission with both Licensed and Unlicensed transmitters as identified within this filing. SAR compliance for body-worn operation is based upon a separation distance of 10mm between the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metal components. The highest reported SAR values for head, body-worn accessory, product specific and simultaneous transmission use conditions are: 0.40 W/kg; 0.13 W/kg; 1.21 W/kg; 0.71 W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application Y/x9kLDLxNvbWWlRTw5riQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

FlexKom Technology Asia Limited
Unit B,11 Floor, Silvercorp International Tower 707-713,Nathan Road
KowLoon,
Hong Kong
  Date of Grant: 08/07/2014

Application Dated: 08/07/2014
 
Attention: PETER Gruenewald

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ABTW-FK-POS5M
Name of Grantee:  FlexKom Technology Asia Limited
Equipment Class: Digital Transmission System
Notes: Flexkom POS
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0171  
CC 15C 2422.0  -  2452.0 0.0108  

Power Output listed is Conducted. This device is approved for simultaneous transmission with both Licensed and Unlicensed transmitters as identified within this filing. SAR compliance for body-worn operation is based upon a separation distance of 10mm between the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metal components. The highest reported SAR values for head, body-worn accessory, product specific and simultaneous transmission use conditions are: 0.40 W/kg; 0.13 W/kg; 1.21 W/kg; 0.71 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application gGsAKgF8wlJJZVu1Afw6QQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/07/2014

Application Dated: 08/07/2014
FlexKom Technology Asia Limited
Unit B,11 Floor, Silvercorp International Tower
707-713,Nathan Road
KowLoon,
Hong Kong
 
Attention: PETER Gruenewald

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ABTW-FK-POS5M
Name of Grantee:  FlexKom Technology Asia Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Flexkom POS
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00228  

Power Output listed is Conducted. This device may transmit simultaneously with other Licensed and Unlicensed transmitters. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application gGsAKgF8wlJJZVu1Afw6QQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

FlexKom Technology Asia Limited
Unit B,11 Floor, Silvercorp International Tower 707-713,Nathan Road
KowLoon,
Hong Kong
  Date of Grant: 08/07/2014

Application Dated: 08/07/2014
 
Attention: PETER Gruenewald

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ABTW-FK-POS5M
Name of Grantee:  FlexKom Technology Asia Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Flexkom POS
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00228  

Power Output listed is Conducted. This device may transmit simultaneously with other Licensed and Unlicensed transmitters. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application bk34+2CTX8kzdjWqjdA/0Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/07/2014

Application Dated: 08/07/2014
FlexKom Technology Asia Limited
Unit B,11 Floor, Silvercorp International Tower
707-713,Nathan Road
KowLoon,
Hong Kong
 
Attention: PETER Gruenewald

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ABTW-FK-POS5M
Name of Grantee:  FlexKom Technology Asia Limited
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Flexkom POS
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 1.104 0.07  PM 248KGXW
BC 22H 824.2  -  848.8 0.774 0.05  PM 245KG7W
BC 22H 826.4  -  846.6 0.155 0.06  PM 4M21F9W
BC 24E 1850.2  -  1909.8 0.715 0.04  PM 249KGXW
BC 24E 1850.2  -  1909.8 0.755 0.03  PM 249KG7W
BC 24E 1852.4  -  1907.6 0.123 0.04  PM 4M18F9W

This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

Power Output listed is ERP for Part 22, and EIRP for Part 24. SAR compliance for body-worn operation is based on a separation distance of 10mm between the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metallic components. The highest reported SAR values for head, body-worn accessory, product specific and simultaneous transmission use conditions are: 0.10 W/kg; 0.58 W/kg; 1.21 W/kg, 0.71 W/kg.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application bk34+2CTX8kzdjWqjdA/0Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

FlexKom Technology Asia Limited
Unit B,11 Floor, Silvercorp International Tower 707-713,Nathan Road
KowLoon,
Hong Kong
  Date of Grant: 08/07/2014

Application Dated: 08/07/2014
 
Attention: PETER Gruenewald

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ABTW-FK-POS5M
Name of Grantee:  FlexKom Technology Asia Limited
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Flexkom POS
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 1.104 0.07  PM 248KGXW
BC 22H 824.2  -  848.8 0.774 0.05  PM 245KG7W
BC 22H 826.4  -  846.6 0.155 0.06  PM 4M21F9W
BC 24E 1850.2  -  1909.8 0.715 0.04  PM 249KGXW
BC 24E 1850.2  -  1909.8 0.755 0.03  PM 249KG7W
BC 24E 1852.4  -  1907.6 0.123 0.04  PM 4M18F9W

This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

Power Output listed is ERP for Part 22, and EIRP for Part 24. SAR compliance for body-worn operation is based on a separation distance of 10mm between the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metallic components. The highest reported SAR values for head, body-worn accessory, product specific and simultaneous transmission use conditions are: 0.10 W/kg; 0.58 W/kg; 1.21 W/kg, 0.71 W/kg.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To: