OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info Adam Elements International Co., LTD.

Adam Elements International Co., LTD. OMNIA Q 10W Wireless Charging Pad with Breathing lights

Page 1 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Page 2 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Page 3 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Page 4 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Page 5 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Page 6 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Page 7 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Page 8 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Page 9 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Page 10 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Page 11 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Page 12 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Page 13 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.

Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 1 of 13 Report No.: SZAWW181115012-02
FCC TEST REPORT
For
Adam Elements International Co., LTD.
OMNIA Q 10W Wireless Charging Pad with Breathing lights
Model No.: OMNIA Q
Prepared For
Address
: Adam Elements International Co., LTD.
: Rm. 3, 10F., No.54, Songjiang Rd., Zhongshan Dist., Taipei City 104,
Taiwan
Prepared By
Address
: Shenzhen Anbotek Compliance Laboratory Limited
: 1/F, Building D, Sogood Science and Technology Park, Sanwei
community, Hangcheng Street, Bao'an District, Shenzhen, Guangdong,
China.518102
Tel: (86) 755-26066440
Report Number
: SZAWW181115012-02
Date of Test
: Nov. 15, 2018
Date of Test
: Nov. 15~Dec. 04, 2018
Date of Report
: Dec. 04, 2018
Fax: (86) 755-26014772
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 2 of 13 Report No.: SZAWW181115012-02
Contents
1. General Information..................................................................................................................................................4
1.1. Client Information......................................................................................................................................... 4
1.2. Description of Device (EUT)........................................................................................................................ 4
1.3. Auxiliary Equipment Used During Test........................................................................................................ 4
1.4. Description Of Test Setup..............................................................................................................................5
1.5. Test Equipment List....................................................................................................................................... 6
1.6. Description of Test Facility........................................................................................................................... 6
2. Measurement and Result...........................................................................................................................................7
2.1. Requirements................................................................................................................................................. 7
2.2. Test Setup.......................................................................................................................................................8
2.3. Test Procedure................................................................................................................................................8
2.4. Test Result......................................................................................................................................................8
2.4.1. Equipment Approval Considerations item 5.b of KDB 680106 D01 v03................................................. 8
2.4.2. Environmental evaluation and exposure limit according to FCC CFR 47 part 1, 1.1307(b), 1.1310....... 9
APPENDIX I -- TEST SETUP PHOTOGRAPH....................................................................................................... 11
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 3 of 13 Report No.: SZAWW181115012-02
TEST REPORT
Applicant
Adam Elements International Co., LTD.
Manufacturer
Adam Elements International Co., LTD.
Product Name
OMNIA Q 10W Wireless Charging Pad with Breathing lights
Model No.
OMNIA Q
Trade Mark
N.A.
Rating(s)
Input: DC 5V, 2.1A / 9V, 2A
Output: DC 5V, 1A / 9V, 1.1A
Test Standard(s)
FCC Part 1.1310, 1.1307(b)
Test Method(s)
KDB680106 D01 RF Exposure Wireless Charging Apps v03
The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to determine the
maximum emission levels emanating from the device and the severe levels of the device can endure and its
performance criterion. The measurement results are contained in this test report and Shenzhen Anbotek
Compliance Laboratory Limited is assumed full of responsibility for the accuracy and completeness of these
measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with the
FCC Part 1.1307 & KDB680106 D01 requirements.
This report applies to above tested sample only and shall not be reproduced in part without written approval of
Shenzhen Anbotek Compliance Laboratory Limited.
Date of Test
Nov. 15~Dec. 04, 2018
Prepared By
(Engineer / Dolly Mo)
Reviewer
(Supervisor / Snowy Meng)
Approved & Authorized Signer
(Manager / Sally Zhang)
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 4 of 13 Report No.: SZAWW181115012-02
1. General Information
1.1. Client Information
Applicant
Adam Elements International Co., LTD.
Address
Rm. 3, 10F., No.54, Songjiang Rd., Zhongshan Dist., Taipei City 104, Taiwan
Manufacturer
Adam Elements International Co., LTD.
Address
Rm. 3, 10F., No.54, Songjiang Rd., Zhongshan Dist., Taipei City 104, Taiwan
Factory
Adam Elements International Co., LTD.
Address
Rm. 3, 10F., No.54, Songjiang Rd., Zhongshan Dist., Taipei City 104, Taiwan
1.2. Description of Device (EUT)
Product Name
: Wireless Charger
Model No.
OMNIA Q
Trade Mark
N.A.
Test Power Supply
AC 120V, 60Hz for adapter
Test Sample No.
S1(Normal Sample), S2(Engineering Sample)
Product
Description
Operation Frequency:
111~205KHz
Modulation Type:
MSK
Antenna Type:
Inductive loop coil Antenna
Antenna Gain(Peak):
0 dBi
Remark: 1) For a more detailed features description, please refer to the manufacturer’s specifications or the
User’s Manual.
1.3. Auxiliary Equipment Used During Test
Adapter
Manufacturer: ZTE
M/N: STC-A2050I1000USBA-C
S/N: 201202102100876
Input: 100-240V~50/60Hz 0.3A
Output: DC 5V, 1000mA
Mobile Phone
Samsung
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 5 of 13 Report No.: SZAWW181115012-02
1.4. Description Of Test Setup
20cm
15 cm
Note: Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm
measured from the center of the probe(s) to the edge of the device
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 6 of 13 Report No.: SZAWW181115012-02
1.5. Test Equipment List
Item
Equipment
Manufacturer
Model No.
Serial No.
Last Cal.
Cal. Interval
Magnetic field meter
NARDA
ELT-400
423623
Dec. 24, 2018
1 Year
E-Field Probe
Narda
EF0391
Q15221
Nov.17, 2017
3 Year
H-Field Probe
Narda
HF3061
Q15835
Nov.17, 2017
3 Year
1.6. Description of Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
FCC-Registration No.: 184111
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registed and fully described in a
report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is
maintained in our files. Registration No. 184111, July 31, 2017.
ISED-Registration No.: 8058A-1
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully described in a
report filed with the (ISED) Innovation, Science and Economic Development Canada. The acceptance letter from
the ISED is maintained in our files. Registration 8058A-1, June 13, 2016.
Test Location
Shenzhen Anbotek Compliance Laboratory Limited.
1/F, Building D, Sogood Science and Technology Park, Sanwei community, Hangcheng Street, Bao'an District,
Shenzhen, Guangdong, China.518102
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 7 of 13 Report No.: SZAWW181115012-02
2. Measurement and Result
2.1. Requirements
According to the item 5.b) of KDB 680106 D01v03:
Inductive wireless power transfer applications that meet all of the following requirements are excluded from
submitting an RF exposure evaluation.
1) Power transfer frequency is less that 1 MHz
2) Output power from each primary coil is less than or equal to 15 watts.
3) The transfer system includes only single primary and secondary coils. This includes charging systems that may
have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of
coils
4) Client device is inserted in or placed directly in contact with the transmitter
5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion)
6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all
simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.
Limits For Maximum Permissible Exposure (MPE)
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 8 of 13 Report No.: SZAWW181115012-02
2.2. Test Setup
20cm
15 cm
Note:Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured
from the center of the probe(s) to the edge of the device
2.3. Test Procedure
1) The RF exposure test was performed in anechoic chamber.
2) The measurement probe was placed at test distance (15 ㎝) which is between the edge of the charger and the
geometric center of probe.
3) The highest emission level was recorded and compared with limit as soon as measurement of each points
(A, B, C, D, E) were completed.(A is the right, B is the back, C is the left, D is the front, and E is the top.)
4) The EUT was measured according to the dictates of KDB 680106 D01 v03.
Remark;
The EUT’s test position A, B, C, D and E is valid for the E and H field measurements.
2.4. Test Result
2.4.1. Equipment Approval Considerations item 5.b of KDB 680106 D01 v03.
1) Power transfer frequency is less that 1 MHz
- The device operate in the frequency range 111~205KHz
2) Output power from each primary coil is less than 15 watts
- The maximum output power of the primary coil is 10W.
3) The transfer system includes only single primary and secondary coils. This includes charging systems that may
have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of
coils
- The transfer system including a charging system with only single primary coils is to detect and allow only
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 9 of 13 Report No.: SZAWW181115012-02
between individual pairs of coils.
4) Client device is inserted in or placed directly in contact with the transmitter
- Client device is placed directly in contact with the transmitter.
5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion)
- The EUT is a Mobile Power Pack with Wireless Charger
6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all
simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.
- The EUT E-Field Strength levels at 15 ㎝ & The EUT H-Field Strength levels at 15 ㎝ are less than 50%
the MPE limit.
The test results please refer to the section 2.4.2
2.4.2. Environmental evaluation and exposure limit according to FCC CFR 47 part 1, 1.1307(b),
1.1310
Temperature:
23.6°C
Relative Humidity:
53 %
Pressure:
1012 hPa
Test Voltage:
AC 120V, 60Hz for adapter
E-Field Strength at 15 cm surrounding the EUT and 15cm above the top surface of the EUT
Battery
power
Frequency
Range
(KHz)
Test
Position
Test
Position
Test
Position
Test
Position
Test
Position
Reference
Limit
(V/m)
Limits
Test
(V/m)
1%
111~205
0.35
0.28
0.36
0.64
0.41
307
614
50%
111~205
1.87
1.72
1.47
1.61
1.83
307
614
99%
111~205
2.28
2.09
2.91
2.67
2.16
307
614
Stand-by
111~205
0.23
0.80
0.54
0.82
0.67
307
614
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 10 of 13 Report No.: SZAWW181115012-02
H-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the EUT
Battery
power
Frequency
Range
(KHz)
Test
Position
Test
Position
Test
Position
Test
Position
Test
Position
Reference
Limit
(A/m)
Limits
Test
(A/m)
1%
111~205
0.058
0.062
0.043
0.049
0.098
0.815
1.63
50%
111~205
0.36
0.32
0.55
0.47
0.49
0.815
1.63
99%
111~205
0.25
0.41
0.57
0.40
0.48
0.815
1.63
Stand-by
111~205
0.39
0.45
0.36
0.06
0.35
0.815
1.63
Remark: All the conditions have been tested. It is found that 10W is the worst mode, and the
data in the report only reflects the worst mode.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 11 of 13 Report No.: SZAWW181115012-02
APPENDIX I -- TEST SETUP PHOTOGRAPH
Photo of MPE Measurement
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 12 of 13 Report No.: SZAWW181115012-02
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 13 of 13 Report No.: SZAWW181115012-02
---------------- End of Report ---------------Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Download: OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Mirror Download [FCC.gov]OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights RF Exposure Info  Adam Elements International Co., LTD.
Document ID4185927
Application IDv7i1lAFAMAvqxTla6NeezA==
Document DescriptionMPE Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize73.95kB (924362 bits)
Date Submitted2019-03-01 00:00:00
Date Available2019-03-01 00:00:00
Creation Date2019-02-28 14:11:53
Producing SoftwareAcrobat Distiller 9.3.3 (Windows)
Document Lastmod2019-02-28 14:12:26
Document TitleRF Exposure Info
Document CreatorPScript5.dll Version 5.2.2
Document Author: Windows

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Windows
Create Date                     : 2019:02:28 14:11:53+08:00
Modify Date                     : 2019:02:28 14:12:26+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2019:02:28 14:12:26+08:00
Producer                        : Acrobat Distiller 9.3.3 (Windows)
Format                          : application/pdf
Title                           : <5C5C3139322E3136382E322E3130325CCAB5D1E9CAD25C215246CAC2D2B5B2BF5C323031382050726F6A6563745C3131D4C2B7DD5C535A41575731383131313530313220BFA8B8F1B6FB20CEDECFDFB3E4204F4D4E4941205120CBD5C8FDC3AB2DD5C5C1A2B1EB2D46434320494428D0C5BFC6295CB1A8B
Creator                         : Windows
Document ID                     : uuid:fe42ff32-dda6-4dd1-ac08-16ce5d5b0c48
Instance ID                     : uuid:3989148f-562e-47f6-9678-814dc9f2a1c7
Page Count                      : 13