OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report Adam Elements International Co., LTD.

Adam Elements International Co., LTD. OMNIA Q 10W Wireless Charging Pad with Breathing lights

Page 1 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 2 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 3 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 4 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 5 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 6 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 7 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 8 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 9 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 10 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 11 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 12 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 13 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 14 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 15 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 16 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 17 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 18 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 19 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 20 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 21 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 22 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 23 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 24 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 25 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 26 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 27 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 28 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 29 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 30 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Page 31 of OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.

Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 1 of 31 Report No.: SZAWW181115012-01
FCC TEST REPORT
For
Adam Elements International Co., LTD.
OMNIA Q 10W Wireless Charging Pad with Breathing lights
Model No.: OMNIA Q
Prepared For
Address
: Adam Elements International Co., LTD.
: Rm. 3, 10F., No.54, Songjiang Rd., Zhongshan Dist., Taipei City 104,
Taiwan
Prepared By
Address
: Shenzhen Anbotek Compliance Laboratory Limited
: 1/F, Building D, Sogood Science and Technology Park, Sanwei
community, Hangcheng Street, Bao'an District, Shenzhen, Guangdong,
China.518102
Tel: (86) 755-26066440
Report Number
: SZAWW181115012-01
Date of Receipt
: Nov. 15, 2018
Date of Test
: Nov. 15~Dec. 04, 2018
Date of Report
: Dec. 04, 2018
Fax: (86) 755-26014772
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 2 of 31 Report No.: SZAWW181115012-01
Contents
1. General Information..................................................................................................................................................4
1.1. Client Information......................................................................................................................................... 4
1.2. Description of Device (EUT)........................................................................................................................ 4
1.3. Auxiliary Equipment Used During Test........................................................................................................ 4
1.4. Description of Test Modes.............................................................................................................................5
1.5. Description Of Test Setup..............................................................................................................................6
1.6. Test Equip1.6. Test Equipment List...............................................................................................................7
1.7. Description of Test Facility........................................................................................................................... 8
2. Summary of Test Results.......................................................................................................................................... 9
3. Conducted Emission Test........................................................................................................................................10
3.1. Test Standard and Limit...............................................................................................................................10
3.2. Test Setup.....................................................................................................................................................10
3.3. Test Procedure..............................................................................................................................................10
3.4. Test Data...................................................................................................................................................... 10
4. Radiation Spurious Emission and Band Edge........................................................................................................ 15
4.1. Test Standard and Limit...............................................................................................................................15
4.2. Test Setup.....................................................................................................................................................15
4.3. Test Procedure..............................................................................................................................................16
4.4. Test Data...................................................................................................................................................... 17
5. Antenna Requirement............................................................................................................................................. 23
5.1. Test Standard and Requirement................................................................................................................... 23
5.2. Antenna Connected Construction................................................................................................................ 23
APPENDIX I -- TEST SETUP PHOTOGRAPH....................................................................................................... 24
APPENDIX II -- EXTERNAL PHOTOGRAPH....................................................................................................... 26
APPENDIX III -- INTERNAL PHOTOGRAPH.......................................................................................................29
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 3 of 31 Report No.: SZAWW181115012-01
TEST REPORT
Applicant
: Adam Elements International Co., LTD.
Manufacturer
: Adam Elements International Co., LTD.
Product Name
: OMNIA Q 10W Wireless Charging Pad with Breathing lights
Model No.
: OMNIA Q
Trade Mark
: N.A.
Rating(s)
Input: DC 5V, 2.1A / 9V, 2A
Output: DC 5V, 1A / 9V, 1.1A
Test Standard(s)
FCC Part15 Subpart C 2018, Paragraph 15.209
Test Method(s)
ANSI C63.10: 2013
The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to determine the
maximum emission levels emanating from the device and the severe levels of the device can endure and its
performance criterion. The measurement results are contained in this test report and Shenzhen Anbotek
Compliance Laboratory Limited is assumed full of responsibility for the accuracy and completeness of these
measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with the
FCC Part 15 Subpart C requirements.
This report applies to above tested sample only and shall not be reproduced in part without written approval of
Shenzhen Anbotek Compliance Laboratory Limited.
Date of Test
Nov. 15~Dec. 04, 2018
Prepared By
(Engineer / Dolly Mo)
Reviewer
(Supervisor / Snowy Meng)
Approved & Authorized Signer
(Manager / Sally Zhang)
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 4 of 31 Report No.: SZAWW181115012-01
1. General Information
1.1. Client Information
Applicant
Adam Elements International Co., LTD.
Address
Rm. 3, 10F., No.54, Songjiang Rd., Zhongshan Dist., Taipei City 104, Taiwan
Manufacturer
Adam Elements International Co., LTD.
Address
Rm. 3, 10F., No.54, Songjiang Rd., Zhongshan Dist., Taipei City 104, Taiwan
Factory
Adam Elements International Co., LTD.
Address
Rm. 3, 10F., No.54, Songjiang Rd., Zhongshan Dist., Taipei City 104, Taiwan
1.2. Description of Device (EUT)
Product Name
OMNIA Q 10W Wireless Charging Pad with Breathing lights
Model No.
OMNIA Q
Trade Mark
N.A.
Test Power Supply
AC 240V, 60Hz for adapter/ AC 120V, 60Hz for adapter
Test Sample No.
S1(Normal Sample), S2(Engineering Sample)
Product
Description
Operation Frequency:
111~205KHz
Modulation Type:
MSK
Antenna Type:
Inductive loop coil Antenna
Antenna Gain(Peak):
0 dBi
Remark: 1) For a more detailed features description, please refer to the manufacturer’s specifications or the
User’s Manual.
1.3. Auxiliary Equipment Used During Test
Adapter
Manufacturer: ZTE
M/N: STC-A2050I1000USBA-C
S/N: 201202102100876
Input: 100-240V~50/60Hz 0.3A
Output: DC 5V, 1000mA
Mobile Phone
Samsung
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 5 of 31 Report No.: SZAWW181115012-01
1.4. Description of Test Modes
To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning
tested base on the consideration of following EUT operation mode or test configuration mode which possible have
effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned
above was evaluated respectively.
Remark: All the conditions have been tested. It is found that 10W is the worst mode, and the data in the
report only reflects the worst mode.
Pretest Mode
Description
Mode 1
Wireless Charge Mode
For Conducted Emission
Final Test Mode
Description
Mode 1
Wireless Charge Mode
For Radiated Emission
Final Test Mode
Description
Mode 1
Wireless Charge Mode
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 6 of 31 Report No.: SZAWW181115012-01
1.5. Description Of Test Setup
CE
USB
E-2
Adapter
E-1
EUT
AC Line
LISN
Mobile Phone
0.8m
Table
Table
1.5m
RE
USB
E-1
EUT
E-2
Adapter
AC Line
Mobile Phone
0.8m
Table
1.5m
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 7 of 31 Report No.: SZAWW181115012-01
1.6. Test Equip1.6. Test Equipment List
Item
Equipment
Manufacturer
Model No.
Serial No.
Last Cal.
Cal.
Interval
Rohde & Schwarz
ENV216
100055
Nov. 05, 2018
1 Year
L.I.S.N.
1.
Artificial Mains
Network
2.
EMI Test Receiver
Rohde & Schwarz
ESPI3
101604
Nov. 05, 2018
1 Year
3.
RF Switching Unit
Compliance Direction
RSU-M2
38303
Nov. 05, 2018
1 Year
4.
Spectrum Analysis
Agilent
E4407B
US39390582
Nov. 05, 2018
1 Year
Agilent
N9020A
MY51170037
Nov. 05, 2018
1 Year
Preamplifier
SKET Electronic
BK1G18G30D
KD17503
Nov. 05, 2018
1 Year
Double Ridged Horn
Instruments
Antenna
corporation
GTH-0118
351600
Nov. 20, 2018
1 Year
Schwarzbeck
VULB9163
VULB 9163-289
Nov. 19, 2018
1 Year
5.
6.
7.
8.
MAX Spectrum
Analysis
Bilog Broadband
Antenna
9.
Loop Antenna
Schwarzbeck
FMZB1519B
00053
Nov. 20, 2018
1 Year
10.
Horn Antenna
A-INFO
LB-180400-KF
J211060628
Nov. 20, 2018
1 Year
11.
Pre-amplifier
SONOMA
310N
186860
Nov. 05, 2018
1 Year
SHURPLE
N/A
N/A
N/A
N/A
YIHENG
YH3000
2017430
Nov. 05, 2018
1 Year
12.
13.
EMI Test Software
EZ-EMC
RF Test Control
System
14.
Power Sensor
DAER
RPR3006W
15I00041SN045
Nov. 05, 2018
1 Year
15.
Power Sensor
DAER
RPR3006W
15I00041SN046
Nov. 05, 2018
1 Year
Agilent
N9020A
MY51170037
Nov. 05, 2018
1 Year
Agilent
N5182A
MY48180656
Nov. 05, 2018
1 Year
16.
17.
MXA Spectrum
Analysis
MXG RF Vector Signal
Generator
18.
Signal Generator
Agilent
E4421B
MY41000743
Nov. 05, 2018
1 Year
19.
DC Power Supply
IVYTECH
IV3605
1804D360510
Apr. 02, 2018
1 Year
ZHONGJIAN
ZJ-KHWS80B
N/A
Nov. 01, 2018
1 Year
20.
Constant Temperature
Humidity Chamber
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 8 of 31 Report No.: SZAWW181115012-01
1.7. Description of Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
FCC-Registration No.: 184111
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registed and fully described in a
report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is
maintained in our files. Registration No. 184111, July 31, 2017.
ISED-Registration No.: 8058A-1
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully described in a
report filed with the (ISED) Innovation, Science and Economic Development Canada. The acceptance letter from
the ISED is maintained in our files. Registration 8058A-1, June 13, 2016.
Test Location
Shenzhen Anbotek Compliance Laboratory Limited.
1/F, Building D, Sogood Science and Technology Park, Sanwei community, Hangcheng Street, Bao'an District,
Shenzhen, Guangdong, China.518102
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 9 of 31 Report No.: SZAWW181115012-01
2. Summary of Test Results
Standard Section
Test Item
Result
FCC Part 15, Paragraph 15.207
Conducted Emission Test
PASS
FCC Part 15, Paragraph 15.209(a)(f)
Spurious Emission
PASS
Antenna Requirement
PASS
Part 15.203
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 10 of 31 Report No.: SZAWW181115012-01
3. Conducted Emission Test
3.1. Test Standard and Limit
Test Standard
FCC Part15 Section 15.207
Maximum RF Line Voltage (dBuV)
Frequency
Test Limit
Quasi-peak Level
Average Level
150kHz~500kHz
66 ~ 56 *
56 ~ 46 *
500kHz~5MHz
56
46
5MHz~30MHz
60
50
Remark: (1) *Decreasing linearly with logarithm of the frequency.
(2) The lower limit shall apply at the transition frequency.
3.2. Test Setup
3.3. Test Procedure
The EUT system is connected to the power mains through a line impedance stabilization network (L.I.S.N.). This
provides a 50ohm coupling impedance for the EUT system. Please refer the block diagram of the test setup and
photographs. Both sides of AC line are checked to find out the maximum conducted emission. In order to find the
maximum emission levels, the relative positions of equipment and all of the interface cables shall be changed
according to FCC ANSI C63.10-2013 on Conducted Emission Measurement.
The bandwidth of test receiver (ESCI) set at 9kHz.
The frequency range from 150kHz to 30MHz is checked.
3.4. Test Data
Please to see the following pages
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 11 of 31 Report No.: SZAWW181115012-01
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Wireless Charge Mode
Test Specification:
AC 240V, 60Hz for adapter
Comment:
Live Line
Tem.: 23.5℃ Hum.: 56%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 12 of 31 Report No.: SZAWW181115012-01
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Wireless Charge Mode
Test Specification:
AC 240V, 60Hz for adapter
Comment:
Neutral Line
Tem.: 23.5℃ Hum.: 56%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 13 of 31 Report No.: SZAWW181115012-01
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Wireless Charge Mode
Test Specification:
AC 120V, 60Hz for adapter
Comment:
Live Line
Tem.: 23.5℃ Hum.: 56%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 14 of 31 Report No.: SZAWW181115012-01
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Wireless Charge Mode
Test Specification:
AC 120V, 60Hz for adapter
Comment:
Neutral Line
Tem.: 23.5℃ Hum.: 56%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 15 of 31 Report No.: SZAWW181115012-01
4. Radiation Spurious Emission and Band Edge
4.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.209 and 15.205
Test Limit
Frequency
Field strength
Limit
(MHz)
(microvolt/meter)
(dBuV/m)
0.009MHz~0.490MHz
2400/F(kHz)
300
0.490MHz-1.705MHz
24000/F(kHz)
30
1.705MHz-30MHz
30
30
30MHz~88MHz
100
40.0
Quasi-peak
88MHz~216MHz
150
43.5
Quasi-peak
216MHz~960MHz
200
46.0
Quasi-peak
960MHz~1000MHz
500
54.0
Quasi-peak
500
54.0
Average
74.0
Peak
Remark
Measurement
distance (m)
Above 1000MHz
Remark:
(1)The lower limit shall apply at the transition frequency.
(2) 15.35(b), Unless otherwise specified, the limit on peak radio frequency emissions is 20dB above the maximum
permitted average emission limit applicable to the equipment under test. This peak limit applies to the total peak
emission level radiated by the device.
4.2. Test Setup
Figure 1. Below 30MHz
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 16 of 31 Report No.: SZAWW181115012-01
Figure 2. 30MHz to 1GHz
Figure 3. Above 1 GHz
4.3. Test Procedure
For below 1GHz: The EUT is placed on a turntable, which is 0.8m above the ground plane.
For above 1GHz: The EUT is placed on a turntable, which is 1.5m above the ground plane.
The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3
meters away from the receiving antenna which is mounted on a antenna tower. The antenna can be moved up and
down from 1 to 4 meters to find out the maximum emission level. Rotated the EUT through three orthogonal axes
to determine the maximum emissions, both horizontal and vertical polarization of the antenna are set on test. The
EUT is tested in 9*6*6 Chamber. The device is evaluated in xyz orientation.
For 9kHz to 150kHz, Set the spectrum analyzer as:
RBW = 200Hz, VBW =1kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.
For 150kHz to 30MHz, Set the spectrum analyzer as:
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 17 of 31 Report No.: SZAWW181115012-01
RBW = 9KHz, VBW =30kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.
For 30MHz to 1000MHz, Set the spectrum analyzer as:
RBW = 100kHz, VBW =300kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.
4.4. Test Data
PASS
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 18 of 31 Report No.: SZAWW181115012-01
Test Results
(Between 9KHz – 30MHz)
Job No.:
SZAWW181115012-01
Standard:
FCC PART15 C _3m
Power Source:
AC 120V, 60Hz for adapter
Test item:
Radiation Test
Temp.(C)/Hum.(%RH):
24.7℃/51%RH
Test Mode:
Mode 1
Distance:
3m
Remark:According to FCC PART 15.209 (d), the emission limits for the frequency bands 9–90 kHz, 110–490 kHz and
above 1000 MHz, Radiated emission limits in these three bands are based on measurements employing an average
detector.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 19 of 31 Report No.: SZAWW181115012-01
(Between 30MHz –1000 MHz)
Job No.:
SZAWW181115012-01
Polarization:
Horizontal
Standard:
FCC PART15 C _3m
Power Source:
AC 120V, 60Hz for adapter
Test item:
Radiation Test
Temp.(C)/Hum.(%RH):
24.3℃/56%RH
Test Mode:
Mode 1
Distance:
3m
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 20 of 31 Report No.: SZAWW181115012-01
Job No.:
SZAWW181115012-01
Polarization:
Vertical
Standard:
FCC PART15 C _3m
Power Source:
AC 120V, 60Hz for adapter
Test item:
Radiation Test
Temp.(C)/Hum.(%RH):
24.3℃/56%RH
Test Mode:
Mode 1
Distance:
3m
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 21 of 31 Report No.: SZAWW181115012-01
Job No.:
SZAWW181115012-01
Polarization:
Horizontal
Standard:
FCC PART15 C _3m
Power Source:
AC 240V, 60Hz for adapter
Test item:
Radiation Test
Temp.(C)/Hum.(%RH):
24.3℃/56%RH
Test Mode:
Mode 1
Distance:
3m
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 22 of 31 Report No.: SZAWW181115012-01
Job No.:
SZAWW181115012-01
Polarization:
Vertical
Standard:
FCC PART15 C _3m
Power Source:
AC 240V, 60Hz for adapter
Test item:
Radiation Test
Temp.(C)/Hum.(%RH):
24.3℃/56%RH
Test Mode:
Mode 1
Distance:
3m
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 23 of 31 Report No.: SZAWW181115012-01
5. Antenna Requirement
5.1. Test Standard and Requirement
Test Standard
FCC Part15 Section 15.203
An intentional radiator shall be designed to ensure that no antenna other than that furnished by
Requirement
the responsible party shall be used with the device. The use of a permanently attached antenna
or of an antenna that uses a unique coupling to the intentional radiator, the manufacturer may
design the unit so that a broken antenna can be replaced by the user, but the use of a standard
5.2. Antenna Connected Construction
The antenna is a Inductive loop coil Antenna which permanently attached, and the best case gain of the antenna is
0 dBi. It complies with the standard requirement.
Antenna
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 24 of 31 Report No.: SZAWW181115012-01
APPENDIX I -- TEST SETUP PHOTOGRAPH
Photo of Conducted Emission Measurement
Photo of Radiation Emission Test
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 25 of 31 Report No.: SZAWW181115012-01
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 26 of 31 Report No.: SZAWW181115012-01
APPENDIX II -- EXTERNAL PHOTOGRAPH
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 27 of 31 Report No.: SZAWW181115012-01
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 28 of 31 Report No.: SZAWW181115012-01
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 29 of 31 Report No.: SZAWW181115012-01
APPENDIX III -- INTERNAL PHOTOGRAPH
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 30 of 31 Report No.: SZAWW181115012-01
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ABY9OMNIA-Q Page 31 of 31 Report No.: SZAWW181115012-01
---------------- End of Report ---------------Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066440
Fax:(86)755-26014772
www.anbotek.com Code:AB-RF-05-a
Download: OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Mirror Download [FCC.gov]OMNIA-Q OMNIA Q 10W Wireless Charging Pad with Breathing lights Test Report  Adam Elements International Co., LTD.
Document ID4185942
Application IDv7i1lAFAMAvqxTla6NeezA==
Document DescriptionRF Test Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize202.53kB (2531582 bits)
Date Submitted2019-03-01 00:00:00
Date Available2019-03-01 00:00:00
Creation Date2019-02-28 14:12:43
Producing SoftwareAcrobat Distiller 9.3.3 (Windows)
Document Lastmod2019-02-28 14:13:10
Document TitleTest Report
Document CreatorPScript5.dll Version 5.2.2
Document Author: Windows

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Windows
Create Date                     : 2019:02:28 14:12:43+08:00
Modify Date                     : 2019:02:28 14:13:10+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Producer                        : Acrobat Distiller 9.3.3 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2019:02:28 14:13:10+08:00
Format                          : application/pdf
Title                           : <5C5C3139322E3136382E322E3130325CCAB5D1E9CAD25C215246CAC2D2B5B2BF5C323031382050726F6A6563745C3131D4C2B7DD5C535A41575731383131313530313220BFA8B8F1B6FB20CEDECFDFB3E4204F4D4E4941205120CBD5C8FDC3AB2DD5C5C1A2B1EB2D46434320494428D0C5BFC6295CB1A8B
Creator                         : Windows
Document ID                     : uuid:34f2e054-66f4-4c86-9226-749914d5689e
Instance ID                     : uuid:ec80434a-735a-4bfa-a719-d50709a6a874
Page Count                      : 31