FCC ID 2AC3I04-90026

CareConnect

by Ceretec Inc.

Grantee Code: 2AC3I   Product Code: 0490026
Latest application date: 2014-09-29

FCC ID Device Details

FCC ID2AC3I04-90026
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AC3I
Product Code0490026
Applicant BusinessCeretec Inc. 🇺🇸
Related Domains 12thmantec.com
Equipment ClassCareConnect
Test FirmShenzhen Timeway Testing Laboratories

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2014-09-29
2402-2480 MHzOriginal Equipment2014-09-29

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2014-09-29PDF 499.2 KB
Internal PhotosInternal Photos2014-09-29PDF 765 KB
External PhotosExternal Photos2014-09-29PDF 862.5 KB
FCC ID Label and LocationID Label/Location Info2014-09-29PDF 153.4 KB
Test Setup PhotosTest Setup Photos2014-09-29PDF 126.1 KB
Test Report for BT4.0Test Report2014-09-29PDF 3.5 MB
Test Report for DSSTest Report2014-09-29PDF 3.6 MB
Test Report for WLANTest Report2014-09-29PDF 4.1 MB
Confidentiality Request LetterCover Letter(s)2014-09-29PDF 395.4 KB
Declaration Letter for AD HoCCover Letter(s)2014-09-29PDF 161 KB
SAR ReportRF Exposure Info2014-09-29PDF 2.8 MB
Block Diagram Metadata onlyBlock DiagramPDF 36.6 KB
Schematics Metadata onlySchematicsPDF 1.2 MB
Operational Description Metadata onlyOperational DescriptionPDF 106.2 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 49.9 KB
Tune Up Information Metadata onlyParts List/Tune Up InfoPDF 99.3 KB

Application Information

Application IDSgS4y/md2oKIajZfbZ7eKA==
Final Action Date2014-09-29
Application PurposeOriginal Equipment
Applicant FRN0023893456
Model04-90026
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionCareConnect
Responsible PartySteve Han, steve.han@12thmantec.com , 714-705-4571
Test FirmJack Chung, Shenzhen Timeway Testing Laboratories, jack72@126.com , 0755-83448688
TCB Emailbentje.holger@phoenix-testlab.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is peak conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory is 0.36 W/kg.

Applications

Application IDDatePurpose
SgS4y/md2oKIajZfbZ7eKA==2014-09-29Original Equipment
KOWssJHy45DRATB/gGGwCA==2014-09-29Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.003300015C28, CC
2402-2480 MHz0.003215C28, CC
2412-2462 MHz0.056615C28, CC
2422-2452 MHz0.023915C28, CC

Grants

TCB Grant - Application SgS4y/md2oKIajZfbZ7eKA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 09/29/2014

Application Dated: 09/29/2014
Ceretec Inc.
7241 Garden Grove Blvd.
Suite G Garden Grove, CA 92841
Garden Grove, CA 92841
 
Attention: Steve Han

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AC3I04-90026
Name of Grantee:  Ceretec Inc.
Equipment Class: Digital Transmission System
Notes: CareConnect
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
28 CC 15C 2412.0  -  2462.0 0.0566  
28 CC 15C 2422.0  -  2452.0 0.0239  
28 CC 15C 2402.0  -  2480.0 0.0032  

Output Power listed is peak conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory is 0.36 W/kg.

28: An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold.
CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application SgS4y/md2oKIajZfbZ7eKA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Ceretec Inc.
7241 Garden Grove Blvd. Suite G Garden Grove, CA 92841
Garden Grove, CA 92841
United States
  Date of Grant: 09/29/2014

Application Dated: 09/29/2014
 
Attention: Steve Han

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AC3I04-90026
Name of Grantee:  Ceretec Inc.
Equipment Class: Digital Transmission System
Notes: CareConnect
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
28 CC 15C 2412.0  -  2462.0 0.0566  
28 CC 15C 2422.0  -  2452.0 0.0239  
28 CC 15C 2402.0  -  2480.0 0.0032  

Output Power listed is peak conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory is 0.36 W/kg.


28: An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold.
CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application KOWssJHy45DRATB/gGGwCA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 09/29/2014

Application Dated: 09/29/2014
Ceretec Inc.
7241 Garden Grove Blvd.
Suite G Garden Grove, CA 92841
Garden Grove, CA 92841
 
Attention: Steve Han

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AC3I04-90026
Name of Grantee:  Ceretec Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CareConnect
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
28 CC 15C 2402.0  -  2480.0 0.0033  

Output Power listed is peak conducted.

28: An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold.
CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application KOWssJHy45DRATB/gGGwCA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Ceretec Inc.
7241 Garden Grove Blvd. Suite G Garden Grove, CA 92841
Garden Grove, CA 92841
United States
  Date of Grant: 09/29/2014

Application Dated: 09/29/2014
 
Attention: Steve Han

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AC3I04-90026
Name of Grantee:  Ceretec Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CareConnect
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
28 CC 15C 2402.0  -  2480.0 0.0033  

Output Power listed is peak conducted.


28: An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold.
CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: