MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.

CONEDERA S.A. Tablet pc

Page 1 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 2 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 3 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 4 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 5 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 6 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 7 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 8 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 9 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 10 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 11 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 12 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 13 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 14 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 15 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 16 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 17 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 18 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 19 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 20 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 21 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 22 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Page 23 of MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.

Page 1 of 23
FCC Test Report
Report No.: AGC02399180201FE01
FCC ID
: 2ACG9-MINI3
APPLICATION PURPOSE
: Original Equipment
PRODUCT DESIGNATION
: Tablet pc
BRAND NAME
: Vantec
MODEL NAME
: mini3
CLIENT
: Conedera S.A.
DATE OF ISSUE
: Apr. 10, 2018
STANDARD(S)
: FCC Part 15B Rules
REPORT VERSION
: V1.0
Attestation of Global Compliance (Shenzhen) Co., Ltd
CAUTION:
This report shall not be reproduced except in full without the written permission of the
test laboratory and shall not be quoted out of context.
Report No.: AGC02399180201FE01
Page 2 of 23
Report Revise Record
Report Version
Revise Time
Issued Date
Valid Version
Notes
V1.0
Apr. 10, 2018
Valid
Original Report
Report No.: AGC02399180201FE01
Page 3 of 23
TABLE OF CONTENTS
1. VERIFICATION OF CONFORMITY.................................................................................................................. 4
2. SYSTEM DESCRIPTION .................................................................................................................................. 5
3. MEASUREMENT UNCERTAINTY ................................................................................................................... 6
4. PRODUCT INFORMATION .............................................................................................................................. 7
5. SUPPORT EQUIPMENT .................................................................................................................................. 8
6. TEST FACILITY ................................................................................................................................................ 9
7. TEST ITEMS AND THE RESULTS ................................................................................................................ 10
8. FCCLINE CONDUCTED EMISSION TEST ................................................................................................... 11
8.1. LIMITS OF LINE CONDUCTED EMISSION TEST .................................................................................. 11
8.2. BLOCK DIAGRAM OF TEST SETUP....................................................................................................... 11
8.3. PROCEDURE OF LINE CONDUCTED EMISSION TEST ....................................................................... 12
8.4. TEST RESULT OF LINE CONDUCTED EMISSION TEST ...................................................................... 13
9. FCC RADIATED EMISSION TEST ................................................................................................................ 15
9.1. EXCEPT FOR CLASS A DIGITAL DEVICES, THE FIELD STRENGTH OF RADIATED EMISSIONS
FROM UNINTENTIONAL RADIATORS AT A DISTANCE OF 3 METERS SHALL NOT EXCEED THE
FOLLOWING VALUES: ................................................................................................................................... 15
9.2. BLOCK DIAGRAM OF TEST SETUP....................................................................................................... 16
9.3. PROCEDURE OF RADIATED EMISSION TEST ..................................................................................... 17
9.4. TEST RESULT OF RADIATED EMISSION TEST .................................................................................... 18
APPENDIX A: PHOTOGRAPHS OF TEST SETUP .......................................................................................... 22
Report No.: AGC02399180201FE01
Page 4 of 23
1. VERIFICATION OF CONFORMITY
Applicant
Conedera S.A.
Address
ALBORADA 10 ETAPA AVE. BENJAMIN CARRION C.C.LA ROTONDA LOCAT
2 Guayaquil Ecuador
Manufacturer
SHENZHEN SUNGWORLD ELECTRONICS CO., LIMITED
Address
4#, North Zone, Shangxue Ind. park, Bantian, Long Gang Dist., Shenzhen,
China.
Product Designation
Tablet pc
Brand Name
Vantec
Test Model
mini3
Date of test
Mar. 15, 2018~Apr. 10, 2018
Deviation
None
Condition of Test Sample
Normal
Report Template
AGCRT-US-IT/AC
The above equipment was tested by Attestation of Global Compliance (Shenzhen) Co., Ltd. for compliance
with the requirements set forth in the FCC Rules and Regulations Part 15, the measurement procedure
according to ANSI C63.4:2014. This said equipment in the configuration described in this report shows the
maximum emission levels emanating from equipment are within the compliance requirements.
The test results of this report relate only to the tested sample identified in this report.
Tested By
Donjon Huang(Huang
Dongyang)
Apr. 10, 2018
Bart Xie(Xie Xiaobin)
Apr. 10, 2018
Reviewed By
Report No.: AGC02399180201FE01
Page 5 of 23
2. SYSTEM DESCRIPTION
EUT test procedure:
1. Connect EUT and peripheral devices (PC) through USB port.
2. Power on the EUT, use the software to transfer data between EUT and PC.
3. Make sure the EUT operates normally during the test.
Test Mode
TEST MODE DESCRIPTION
NO.
TEST MODE DESCRIPTION
WORST
USB (connection for data transferring)
Note:
1. V means EMI worst mode
2. USB cable is provided by AGC-Lab.
Report No.: AGC02399180201FE01
Page 6 of 23
3. MEASUREMENT UNCERTAINTY
The uncertainty is calculated using the methods suggested in the “Guide to the Expression of Uncertainty in
measurement” (GUM) published by CISPR and ANSI.
- Uncertainty of Conducted Emission, Uc = ±3.2 dB
- Uncertainty of Radiated Emission below 1GHz, Uc = ±3.9 dB
- Uncertainty of Radiated Emission above 1GHz, Uc = ±4.8 dB
Report No.: AGC02399180201FE01
Page 7 of 23
4. PRODUCT INFORMATION
Housing Type
Plastic and metal
Hardware Version
E706W02
Software Version
N/A
EUT Input Rating
DC3.7V by battery or DC 5V by Micro-USB
I/O Port Information (
Applicable
Not Applicable)
I/O Port of EUT
I/O Port Type
Q’TY
Cable
Tested with
USB Port
earphone
Report No.: AGC02399180201FE01
Page 8 of 23
5. SUPPORT EQUIPMENT
Device Type
Manufacturer
Model Name
Serial No.
Data Cable
Power Cable
PC
Apple Inc.
--
--
--
0.8m Unshielded
Adapter
Apple Inc.
--
--
--
1.25m Unshielded
Note: All the above equipment/cables were placed in worse case positions to maximize emission signals during
emission test.
Report No.: AGC02399180201FE01
Page 9 of 23
6. TEST FACILITY
Site
Attestation of Global Compliance (Shenzhen) Co., Ltd
1-2F., Bldg.2, No.1-4, Chaxi Sanwei Technical Industrial Park, Gushu, Xixiang,
Bao’an District B112-B113, Bldg.12, Baoan Bldg Materials Center, No.1 of Xixiang
Inner Ring Road, Baoan District, Shenzhen 518012
Location
NVLAP LAB CODE
600153-0
Designation Number
CN5028
Description
Attestation of Global Compliance(Shenzhen) Co., Ltd is accredited by National
Voluntary Laboratory Accreditation program, NVLAP Code 600153-0
TEST EQUIPMENT OF CONDUCTED EMISSION TEST
Equipment
Manufacturer
Model
S/N
Cal. Date
Cal. Due
TEST RECEIVER
R&S
ESPI
101206
Jun.20, 2017
Jun.19, 2018
LISN
R&S
ESH2-Z5
100086
Aug.21, 2017
Aug.20, 2018
TEST EQUIPMENT OF RADIATED EMISSION TEST
Equipment
Manufacturer
Model
S/N
Cal. Date
Cal. Due
TEST RECEIVER
R&S
ESCI
10096
Jun.20, 2017
Jun.19, 2018
EXA Signal
Analyzer
Aglient
N9010A
MY53470504
Dec.08, 2017
Dec.07, 2018
Horn antenna
SCHWARZBECK
BBHA 9170
#768
Sep.20, 2017
Sep.19, 2018
preamplifier
ChengYi
EMC184045SE
980508
Sep.15, 2017
Sep.14, 2018
ETS LINDGREN
3117
00034609
May.18, 2017
May.17, 2019
SCHWARZBECK
BBV 9718
9718-205
Jun.20, 2017
Jun.19, 2018
SCHWARZBECK
VULB9168
D69250
Sep.28, 2017
Sep.27, 2018
Double-Ridged
Waveguide Horn
Broadband
Preamplifier
ANTENNA
Report No.: AGC02399180201FE01
Page 10 of 23
7. TEST ITEMS AND THE RESULTS
Test item
CONDUCTED
EMISSION
RADIATED
EMISSION
Test Requirement
Test Method
Class/Severity
Result
FCC Part 15.107 Rules
ANSI C63.4:2014
Class B
Pass
FCC Part 15.109 Rules
ANSI C63.4:2014
Class B
Pass
Report No.: AGC02399180201FE01
Page 11 of 23
8. FCCLINE CONDUCTED EMISSION TEST
8.1. LIMITS OF LINE CONDUCTED EMISSION TEST
Frequency
Maximum RF Line Voltage
Q.P.( dBuV)
Average( dBuV)
150kHz-500kHz
66-56
56-46
500kHz-5MHz
56
46
5MHz-30MHz
60
50
Note:
1. The lower limit shall apply at the transition frequency.
2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50MHz.
8.2. BLOCK DIAGRAM OF TEST SETUP
Report No.: AGC02399180201FE01
Page 12 of 23
8.3. PROCEDURE OF LINE CONDUCTED EMISSION TEST
(1) The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is
placed on the ground plane as per ANSI C63.4 (see Test Facility for the dimensions of the ground plane
used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12
mm non-conductive covering to insulate the EUT from the ground plane.
(2) Support equipment, if needed, was placed as per ANSI C63.4.
(3) All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4.
(4) The EUT received DC5V power from PC with receive AC120V/60Hz power from a LISN.
(5) The EUT test program was started. Emissions were measured on each current carrying line of the EUT
using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two
monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1
connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1
connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
(6) Analyzer / Receiver scanned from 150 kHz to 30MHz for emissions in each of the test modes.
(7) During the above scans, the emissions were maximized by cable manipulation.
(8) A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions.
(9) Emission frequency and amplitude were recorded into a computer in which correction factors were used
to calculate the emission level and compare reading to the applicable limit. If EUT emission level was
less –2dB to the A.V. limit in Peak mode, then the emission signal was re-checked using Q.P and
Average detector.
The test data of the worst case condition (mode 1) was reported on the Summary Data page.
Report No.: AGC02399180201FE01
Page 13 of 23
8.4. TEST RESULT OF LINE CONDUCTED EMISSION TEST
LINE CONDUCTED EMISSION TEST-L
Report No.: AGC02399180201FE01
Page 14 of 23
LINE CONDUCTED EMISSION TEST-N
RESULT: PASS
Report No.: AGC02399180201FE01
Page 15 of 23
9. FCC RADIATED EMISSION TEST
9.1. EXCEPT FOR CLASS A DIGITAL DEVICES, THE FIELD STRENGTH OF RADIATED EMISSIONS
FROM UNINTENTIONAL RADIATORS AT A DISTANCE OF 3 METERS SHALL NOT EXCEED THE
FOLLOWING VALUES:
Frequency
(MHz)
Distance
(m)
Maximum Field Strength Limit
(dBuV/m/ Q.P.)
30~88
40.0
88~216
43.5
216~960
46.0
Above 960
54.0
Note: The lower limit shall apply at the transition frequency.
9.1.1 The following table is the setting of spectrum analyzer and receiver:
Spectrum Parameter
Setting
Start ~Stop Frequency
9KHz~150KHz/RB 200Hz for QP
Start ~Stop Frequency
150KHz~30MHz/RB 9KHz for QP
Start ~Stop Frequency
30MHz~1000MHz/RB 120KHz for QP
Start ~Stop Frequency
1GHz~26.5GHz
1MHz/1MHz for Peak, 1MHz/10Hz for Average
Receiver Parameter
Setting
Start ~Stop Frequency
9KHz~150KHz/RB 200Hz for QP
Start ~Stop Frequency
150KHz~30MHz/RB 9KHz for QP
Start ~Stop Frequency
30MHz~1000MHz/RB 120KHz for QP
Report No.: AGC02399180201FE01
Page 16 of 23
9.2. BLOCK DIAGRAM OF TEST SETUP
System Diagram of Connections between EUT and Simulators
1-4m
EUT
3m
0.8 m
Amplifier
Spectrum
Analyzer
RADIATED EMISSION TEST SETUP ABOVE 1000MHz
Report No.: AGC02399180201FE01
Page 17 of 23
9.3. PROCEDURE OF RADIATED EMISSION TEST
1. Configure the EUT according to ANSI C63.4. The EUT was placed on the top of the turntable 0.8 meter
above ground. The phase center of the receiving antenna mounted on the top of a height-variable
antenna tower was placed 3 meters far away from the turntable.
2. Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to determine
the position of the highest radiation.
3. The height of the broadband receiving antenna was varied between one meter and four meters above
ground to find the maximum emissions field strength of both horizontal and vertical polarization.
4. For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the turntable was
rotated (from 0 degree to 360 degrees) to find the maximum reading.
5. Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified bandwidth
under Maximum Hold Mode.
6. For emissions above 1GHz, use 1MHz RBW and 3MHz VBW for peak reading. Then 1MHz RBW and
3MHz VBW for average reading in spectrum analyzer. The EUT was placed on the top of the turntable 0.8
meter above ground. The phase center of the receiving antenna mounted on the top of a height-variable
antenna tower was placed 3 meters far away from the turntable.
7. When the radiated emissions limits are expressed in terms of the average value of the emissions, and
pulsed operation is employed, the measurement field strength shall be determined by averaging over one
complete pulse train, including blanking intervals, as long as the pulse train does not exceed 0.1 seconds.
As an alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases where the
pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the average
absolute voltage during a 0.1 second interval during which the field strength is at its maximum values.
8.If the emissions level of the EUT in peak mode was 3 dB lower than the average limit specified, then
testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not
have 3 dB margin will be repeated one by one using the quasi-peak method for below 1GHz.
9. If the emission level of the EUT in peak mode was 10 dB lower than the limit specified, then testing could
be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have
10 dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and
then reported in a data sheet.
10. In case the emission is lower than 30MHz, loop antenna has to be used for measurement and the
recorded data should be QP measured by receiver. High - Low scan is not required in this case.
11. The test data of the worst case condition (mode 1) was reported on the Summary Data page.
Report No.: AGC02399180201FE01
Page 18 of 23
9.4. TEST RESULT OF RADIATED EMISSION TEST
RADIATED EMISSION TEST AT 3M DISTANCE-HORIZONTAL
RESULT: PASS
Report No.: AGC02399180201FE01
Page 19 of 23
RADIATED EMISSION TEST AT 3M DISTANCE-VERTICAL
RESULT: PASS
Note: 1.Measurement = Reading + Factor, Over = Measurement – Limit.
2. The “Factor” value can be calculated automatically by software of measurement system.
Report No.: AGC02399180201FE01
Page 20 of 23
RADIATED EMISSION ABOVE 1GHZ (1-10TH HARMONICS) –HORIZONTAL
Report No.: AGC02399180201FE01
Page 21 of 23
RADIATED EMISSION ABOVE 1GHZ (1-10TH HARMONICS) –VERTICAL
Note: 1. Emissions range from 6GHz to 12.5GHz have 20dB margin. No recording in the test report.
2. Factor=Antenna Factor + Cable loss - Amplifier gain, Margin=Measurement-Limit.
3. The “Factor” value can be calculated automatically by software of measurement system.
Report No.: AGC02399180201FE01
Page 22 of 23
APPENDIX A: PHOTOGRAPHS OF TEST SETUP
FCC LINE CONDUCTED EMISSION TEST SETUP
FCC RADIATED EMISSION TEST SETUP
Report No.: AGC02399180201FE01
Page 23 of 23
FCC RADIATED EMISSION TEST SETUP
----END OF REPORT----
Download: MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Mirror Download [FCC.gov]MINI3 Tablet pc Test Report EMC COMPLIANCE CONEDERA S.A.
Document ID3838986
Application IDI9ge9FOdkJl3D0/EWnT7qg==
Document Description14_mini3 TestRpt JBP
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize144.13kB (1801577 bits)
Date Submitted2018-05-04 00:00:00
Date Available2018-05-04 00:00:00
Creation Date2018-04-23 17:02:36
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2018-05-03 11:28:31
Document TitleEMC COMPLIANCE TEST REPORT
Document CreatorMicrosoft® Office Word 2007
Document Author: Simon

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Create Date                     : 2018:04:23 17:02:36+08:00
Creator Tool                    : Microsoft® Office Word 2007
Modify Date                     : 2018:05:03 11:28:31+08:00
Metadata Date                   : 2018:05:03 11:28:31+08:00
Format                          : application/pdf
Creator                         : Simon
Title                           : EMC COMPLIANCE TEST REPORT
Producer                        : Microsoft® Office Word 2007
Document ID                     : uuid:e564531a-f71a-4d06-9152-fda28e29a9b7
Instance ID                     : uuid:4598ef50-c3bc-4700-95b8-822b905b9f09
Page Count                      : 23
Language                        : zh-CN
Author                          : Simon