FCC ID 2ACHL-AIR11M1
Continuous Positive Airway Pressure (CPAP) Device
by ResMed Pty Ltd
Grantee Code: 2ACHL Product Code: AIR11M1
Latest application date: 2021-11-18
FCC ID Device Details
| FCC ID | 2ACHL-AIR11M1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2ACHL |
| Product Code | AIR11M1 |
| Applicant Business | ResMed Pty Ltd 🇦🇺 |
| Related Domains | |
| Equipment Class | Continuous Positive Airway Pressure (CPAP) Device |
| Test Firm | DEKRA Testing and Certification, S.A.U. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 729-746 MHz | Original Equipment | 2021-11-18 |
| 699-716 MHz | Original Equipment | 2021-11-18 |
| 2400-2483.5 MHz | Original Equipment | 2021-11-18 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Addendum_User manual | Users Manual | 2022-05-17 | PDF 632.1 KB |
| AirSense 11 User Guide AMER ENG CAT M1v2 | Users Manual | 2022-05-17 | PDF 3.3 MB |
| AirSense 11_Internal Photographsv2 | Internal Photos | 2022-05-17 | PDF 1.3 MB |
| AirSense 11_External Photographs | External Photos | 2022-05-17 | PDF 149 KB |
| AirSense11_FCC-ISED_Label design | ID Label/Location Info | 2021-11-18 | PDF 1.5 MB |
| eLB1392-074 FCC & ISED Labelling Submission Air11 r5_02 Metadata only | ID Label/Location Info | 2021-11-18 | PDF 1.5 MB |
| 68649RAN.001.pdf-photographs | Test Setup Photos | 2022-05-17 | PDF 421.2 KB |
| 68649REM.002_Photographs | Test Setup Photos | 2022-05-17 | PDF 3.1 MB |
| 68649RRF.001_Photographs | Test Setup Photos | 2022-05-17 | PDF 905.9 KB |
| 68649RRF.002_Photographs | Test Setup Photos | 2022-05-17 | PDF 1 MB |
| 68649RRF.003_Photographs | Test Setup Photos | 2022-05-17 | PDF 901.2 KB |
| 68649RRF004_Photographs | Test Setup Photos | 2022-05-17 | PDF 517.8 KB |
| 191019009RFM-2R1_FCC Part 22&24&27&90 & RSS 130,132,133,139,199Report (LTE Repor | Test Report | 2021-11-18 | PDF 5.7 MB |
| 68649RAN.001s (SAR) - FCC | Test Report | 2021-11-18 | PDF 3.6 MB |
| 68649REM.002A2s | Test Report | 2021-11-18 | PDF 2.2 MB |
| 68649RRF.002s | Test Report | 2021-11-18 | PDF 2.4 MB |
| 68649RRF.003s | Test Report | 2021-11-18 | PDF 4.1 MB |
| 68649RRF.004s | Test Report | 2021-11-18 | PDF 1.9 MB |
| 68649RRF001s_Part1 | Test Report | 2021-11-18 | PDF 5 MB |
| 68649RRF001s_Part2 | Test Report | 2021-11-18 | PDF 5 MB |
| AirSense 11 - Integration Letter | Cover Letter(s) | 2021-11-18 | PDF 31.4 KB |
| AirSense 11 - Similarities and Differences | Cover Letter(s) | 2021-11-18 | PDF 39.8 KB |
| AirSense11 - Model Names _ Declaration of Equivalence | Cover Letter(s) | 2021-11-18 | PDF 296.6 KB |
| FCB012_02 FCC Confidentiality Request | Cover Letter(s) | 2021-11-18 | PDF 386.9 KB |
| FCC Agent letter_Pacific | Cover Letter(s) | 2021-11-18 | PDF 333.6 KB |
| eLB1392-074 FCC & ISED Labelling Submission Air11 r5_02 Metadata only | Cover Letter(s) | 2021-11-18 | PDF 1.5 MB |
| AirSense11_Block Diagram Metadata only | Block Diagram | PDF 124.3 KB | |
| AirSense11_Block Diagram_BTLE SOC Metadata only | Block Diagram | PDF 284.1 KB | |
| EXS62-W_ Block diagram Metadata only | Block Diagram | PDF 678.7 KB | |
| AirSense11_Schematics Metadata only | Schematics | PDF 1.6 MB | |
| EXS62-W_Circuit Diagram Metadata only | Schematics | PDF 148.1 KB | |
| AirSense 11 BLE Antenna Values Metadata only | Operational Description | PDF 142.3 KB | |
| AirSense 11 Cellular Antenna Specs Metadata only | Operational Description | PDF 107 KB | |
| AirSense 11 Cellular Antenna Specs_Datasheet Metadata only | Operational Description | PDF 2.7 MB | |
| AirSense 11_Operational Description_BLE SoC Metadata only | Operational Description | PDF 2.3 MB | |
| AirSense 11_Operational Descriptionv02 Metadata only | Operational Description | PDF 279.2 KB | |
| AirSense11_Base_BOM Metadata only | Operational Description | PDF 106.4 KB | |
| EXS62-W_Circuit Diagram Metadata only | Operational Description | PDF 148.1 KB | |
| exs62-w_exs82-w_hid_v01200a_datasheet Metadata only | Operational Description | PDF 2.5 MB | |
| AirSense11_Base_BOM Metadata only | Parts List/Tune Up Info | PDF 106.4 KB | |
| AirSense11_M1_MainPCBA_BOM Metadata only | Parts List/Tune Up Info | PDF 182.5 KB | |
| AirSense11_Tune-up declaration Metadata only | Parts List/Tune Up Info | PDF 291.2 KB | |
| AirSense11_Tune-up procedure Metadata only | Parts List/Tune Up Info | PDF 845.7 KB | |
| EXS62-W_BOM Metadata only | Parts List/Tune Up Info | PDF 108.2 KB |
Application Information
| Application ID | xJMGwE/UmNH/ew8ntf9p/w== |
|---|---|
| Final Action Date | 2021-11-18 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0023645450 |
| Model | AIR11M1 |
| Frequency Range | 729-746 MHz |
| Equipment Class | CXX - Communications Rcvr for use w/ licensed Tx and CBs |
| Device Description | Continuous Positive Airway Pressure (CPAP) Device |
| Responsible Party | Christopher Jenkins, Associate Manager - Systems Engineering, Christopher.Jenkins@resmed.com.au |
| Agent | Mario Mario Mario, Dekra Testing and Certification S.A.U, mario.baudet@dekra.com |
| Test Firm | Rafael Lopez Martin, DEKRA Testing and Certification, S.A.U., rafael.lopez@dekra.com |
| TCB Email | admin.rcb.es@dekra.com |
| TCB Scope | A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 05/17/2022 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| xJMGwE/UmNH/ew8ntf9p/w== | 2021-11-18 | Original Equipment |
| tQWodbHVqhvE9u1PQgldpQ== | 2021-11-18 | Original Equipment |
| jqmnXvKSPFYHHhHxi/VFAQ== | 2021-11-18 | Original Equipment |
| MqkEyaAvstRPdVWBAlvNeA== | 2021-11-18 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 699-716 MHz | 0.136144 | 0.0085ppm | 990KW7D | 27 | |
| 699-716 MHz | 0.139316 | 0.0085ppm | 1M13G7D | 27 | |
| 729-746 MHz | 15B | CC | |||
| 746-756 MHz | 15B | CC | |||
| 777-787 MHz | 0.138038 | 0.0092ppm | 1M13G7D | 27 | |
| 777-787 MHz | 0.138676 | 0.0092ppm | 970KW7D | 27 | |
| 777-787 MHz | 0.135207 | 0.0092ppm | 990KW7D | 27 | |
| 814-824 MHz | 0.0139959 | 0.0055ppm | 1M14G7D | 9 | |
| 814-824 MHz | 0.144212 | 0.0055ppm | 1M00W7D | 9 | |
| 824-849 MHz | 0.155597 | 0.0055ppm | 1M15G7D | 22H | |
| 824-849 MHz | 0.153462 | 0.0055ppm | 990KW7D | 22H | |
| 824 MHz | 0.98175 | 0.0055ppm | 1M12G7D | 22H, 9 | |
| 824-849 MHz | 0.138995 | 0.0062ppm | 1M12G7D | 22H | |
| 824-849 MHz | 0.144212 | 0.0062ppm | 990KW7D | 22H | |
| 859-894 MHz | 15B | CC | |||
| 869-894 MHz | 15B | CC | |||
| 1710-1780 MHz | 0.130918 | 0.0045ppm | 1M12G7D | 27 | |
| 1710-1780 MHz | 0.127644 | 0.0045ppm | 1M13G7D | 27 | |
| 1710-1780 MHz | 0.136458 | 0.0045ppm | 1M03W7D | 27 | |
| 1710-1755 MHz | 0.151356 | 0.0025ppm | 1M15G7D | 27 | |
| 1710-1755 MHz | 0.136144 | 0.0025ppm | 940KW7D | 27 | |
| 1710-1755 MHz | 0.135831 | 0.0025ppm | 1M00W7D | 27 | |
| 1850-1915 MHz | 0.0140281 | 0.0039ppm | 1M13G7D | 24E | |
| 1850-1915 MHz | 0.138995 | 0.0039ppm | 960KW7D | 24E | |
| 1850-1915 MHz | 0.0136773 | 0.0039ppm | 1M03W7D | 24E | |
| 1850-1910 MHz | 0.142889 | 0.0039ppm | 1M15G7D | 24E | |
| 2400-2483.5 MHz | 0.0013550 | 15C | CC |
Grants
TCB Grant - Application xJMGwE/UmNH/ew8ntf9p/w==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
DEKRA Testing and Certification, S.A.U. Parque Tecnologico de Andalucia, Calle Severo Ochoa 2 y 6 Campanillas - Malaga, 29590 Spain |
Date of Grant: 11/18/2021 Application Dated: 11/17/2021 |
| ResMed Pty Ltd |
| 1 Elizabeth Macarthur Dr |
| Bella Vista, 2153 Australia |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | Communications Rcvr for use w/ licensed Tx and CBs |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | 869.0 - 894.0 | |||
| CC | 15B | 729.0 - 746.0 | |||
| CC | 15B | 746.0 - 756.0 | |||
| CC | 15B | 859.0 - 894.0 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application xJMGwE/UmNH/ew8ntf9p/w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ResMed Pty Ltd 1 Elizabeth Macarthur Dr Bella Vista, 2153 Australia |
Date of Grant: 11/18/2021 Application Dated: 11/17/2021 |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | Communications Rcvr for use w/ licensed Tx and CBs |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | 869.0 - 894.0 | |||
| CC | 15B | 729.0 - 746.0 | |||
| CC | 15B | 746.0 - 756.0 | |||
| CC | 15B | 859.0 - 894.0 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
DEKRA Testing and Certification, S.A.U. Parque Tecnologico de Andalucia, Calle Severo Ochoa 2 y 6 Campanillas - Malaga, 29590 Spain |
Date of Grant: 11/18/2021 Application Dated: 11/17/2021 |
| ResMed Pty Ltd |
| 1 Elizabeth Macarthur Dr |
| Bella Vista, 2153 Australia |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.0 - 1910.0 | 0.150314 | 0.0039 PM | 970KW7D | |
| 24E | 1850.0 - 1910.0 | 0.097724 | 0.0039 PM | 1M87W7D | |
| 24E | 1850.0 - 1910.0 | 0.142889 | 0.0039 PM | 1M15G7D | |
| 27 | 1710.0 - 1755.0 | 0.151356 | 0.0025 PM | 1M15G7D | |
| 27 | 1710.0 - 1755.0 | 0.136144 | 0.0025 PM | 940KW7D | |
| 27 | 1710.0 - 1755.0 | 0.135831 | 0.0025 PM | 1M00W7D | |
| 22H | 824.0 - 849.0 | 0.138995 | 0.0062 PM | 1M12G7D | |
| 22H | 824.0 - 849.0 | 0.144212 | 0.0062 PM | 990KW7D | |
| 27 | 699.0 - 716.0 | 0.139316 | 0.0085 PM | 1M13G7D | |
| 27 | 699.0 - 716.0 | 0.136144 | 0.0085 PM | 990KW7D | |
| 27 | 777.0 - 787.0 | 0.138038 | 0.0092 PM | 1M13G7D | |
| 27 | 777.0 - 787.0 | 0.138676 | 0.0092 PM | 970KW7D | |
| 27 | 777.0 - 787.0 | 0.135207 | 0.0092 PM | 990KW7D | |
| 24E | 1850.0 - 1915.0 | 0.0140281 | 0.0039 PM | 1M13G7D | |
| 24E | 1850.0 - 1915.0 | 0.138995 | 0.0039 PM | 960KW7D | |
| 24E | 1850.0 - 1915.0 | 0.0136773 | 0.0039 PM | 1M03W7D | |
| 22H | 824.0 - 849.0 | 0.155597 | 0.0055 PM | 1M15G7D | |
| 22H | 824.0 - 849.0 | 0.153462 | 0.0055 PM | 990KW7D | |
| 90 | 814.0 - 824.0 | 0.0139959 | 0.0055 PM | 1M14G7D | |
| 90 | 814.0 - 824.0 | 0.144212 | 0.0055 PM | 1M00W7D | |
| 90, 22H | 824.0 - 824.0 | 0.98175 | 0.0055 PM | 1M12G7D | |
| 27 | 1710.0 - 1780.0 | 0.130918 | 0.0045 PM | 1M12G7D | |
| 27 | 1710.0 - 1780.0 | 0.127644 | 0.0045 PM | 1M13G7D | |
| 27 | 1710.0 - 1780.0 | 0.136458 | 0.0045 PM | 1M03W7D |
| Output power is conducted. Multi-transmitter configurations, supporting simultaneous transmission, have been evaluated as described in this filling. Other multi-transmitter configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f), §15.31(h) and §15.31(k) composite system and §2.1 terms and concepts. SAR compliance is based on a separation distance of 24 mm. The highest reported SAR for Head SAR, body, and simultaneous transmission exposure conditions are 0.102W/kg, 0.079 W/kg, and 0.1299 W/kg, respectively |
EAS Grant - Application tQWodbHVqhvE9u1PQgldpQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ResMed Pty Ltd 1 Elizabeth Macarthur Dr Bella Vista, 2153 Australia |
Date of Grant: 11/18/2021 Application Dated: 11/17/2021 |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.0 - 1910.0 | 0.150314 | 0.0039 PM | 970KW7D | |
| 24E | 1850.0 - 1910.0 | 0.097724 | 0.0039 PM | 1M87W7D | |
| 24E | 1850.0 - 1910.0 | 0.142889 | 0.0039 PM | 1M15G7D | |
| 27 | 1710.0 - 1755.0 | 0.151356 | 0.0025 PM | 1M15G7D | |
| 27 | 1710.0 - 1755.0 | 0.136144 | 0.0025 PM | 940KW7D | |
| 27 | 1710.0 - 1755.0 | 0.135831 | 0.0025 PM | 1M00W7D | |
| 22H | 824.0 - 849.0 | 0.138995 | 0.0062 PM | 1M12G7D | |
| 22H | 824.0 - 849.0 | 0.144212 | 0.0062 PM | 990KW7D | |
| 27 | 699.0 - 716.0 | 0.139316 | 0.0085 PM | 1M13G7D | |
| 27 | 699.0 - 716.0 | 0.136144 | 0.0085 PM | 990KW7D | |
| 27 | 777.0 - 787.0 | 0.138038 | 0.0092 PM | 1M13G7D | |
| 27 | 777.0 - 787.0 | 0.138676 | 0.0092 PM | 970KW7D | |
| 27 | 777.0 - 787.0 | 0.135207 | 0.0092 PM | 990KW7D | |
| 24E | 1850.0 - 1915.0 | 0.0140281 | 0.0039 PM | 1M13G7D | |
| 24E | 1850.0 - 1915.0 | 0.138995 | 0.0039 PM | 960KW7D | |
| 24E | 1850.0 - 1915.0 | 0.0136773 | 0.0039 PM | 1M03W7D | |
| 22H | 824.0 - 849.0 | 0.155597 | 0.0055 PM | 1M15G7D | |
| 22H | 824.0 - 849.0 | 0.153462 | 0.0055 PM | 990KW7D | |
| 90 | 814.0 - 824.0 | 0.0139959 | 0.0055 PM | 1M14G7D | |
| 90 | 814.0 - 824.0 | 0.144212 | 0.0055 PM | 1M00W7D | |
| 90, 22H | 824.0 - 824.0 | 0.98175 | 0.0055 PM | 1M12G7D | |
| 27 | 1710.0 - 1780.0 | 0.130918 | 0.0045 PM | 1M12G7D | |
| 27 | 1710.0 - 1780.0 | 0.127644 | 0.0045 PM | 1M13G7D | |
| 27 | 1710.0 - 1780.0 | 0.136458 | 0.0045 PM | 1M03W7D |
| Output power is conducted. Multi-transmitter configurations, supporting simultaneous transmission, have been evaluated as described in this filling. Other multi-transmitter configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f), §15.31(h) and §15.31(k) composite system and §2.1 terms and concepts. SAR compliance is based on a separation distance of 24 mm. The highest reported SAR for Head SAR, body, and simultaneous transmission exposure conditions are 0.102W/kg, 0.079 W/kg, and 0.1299 W/kg, respectively |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
DEKRA Testing and Certification, S.A.U. Parque Tecnologico de Andalucia, Calle Severo Ochoa 2 y 6 Campanillas - Malaga, 29590 Spain |
Date of Grant: 11/18/2021 Application Dated: 11/17/2021 |
| ResMed Pty Ltd |
| 1 Elizabeth Macarthur Dr |
| Bella Vista, 2153 Australia |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | Part 15 Class B Digital Device |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15B | - |
EAS Grant - Application MqkEyaAvstRPdVWBAlvNeA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ResMed Pty Ltd 1 Elizabeth Macarthur Dr Bella Vista, 2153 Australia |
Date of Grant: 11/18/2021 Application Dated: 11/17/2021 |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | Part 15 Class B Digital Device |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15B | - |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
DEKRA Testing and Certification, S.A.U. Parque Tecnologico de Andalucia, Calle Severo Ochoa 2 y 6 Campanillas - Malaga, 29590 Spain |
Date of Grant: 11/18/2021 Application Dated: 11/18/2021 |
| ResMed Pty Ltd |
| 1 Elizabeth Macarthur Dr |
| Bella Vista, 2153 Australia |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2400.0 - 2483.5 | 0.001355 |
| Output power is conducted. Multi-transmitter configurations, supporting simultaneous transmission, have been evaluated as described in this filling. Other multi-transmitter configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f), §15.31(h) and §15.31(k) composite system and §2.1 terms and concepts. This device meets the SAR Test Exclusion threshold specified in KDB447498 and since then, it is authorized for portable operation. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application jqmnXvKSPFYHHhHxi/VFAQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ResMed Pty Ltd 1 Elizabeth Macarthur Dr Bella Vista, 2153 Australia |
Date of Grant: 11/18/2021 Application Dated: 11/18/2021 |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2400.0 - 2483.5 | 0.001355 |
| Output power is conducted. Multi-transmitter configurations, supporting simultaneous transmission, have been evaluated as described in this filling. Other multi-transmitter configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f), §15.31(h) and §15.31(k) composite system and §2.1 terms and concepts. This device meets the SAR Test Exclusion threshold specified in KDB447498 and since then, it is authorized for portable operation. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |