FCC ID 2ACHL-AIR11M1G22
Continuous Positive Airway Pressure (CPAP) Device
by ResMed Pty Ltd
Grantee Code: 2ACHL Product Code: AIR11M1G22
Latest application date: 2022-12-30
FCC ID Device Details
| FCC ID | 2ACHL-AIR11M1G22 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2ACHL |
| Product Code | AIR11M1G22 |
| Applicant Business | ResMed Pty Ltd 🇦🇺 |
| Related Domains | |
| Equipment Class | Continuous Positive Airway Pressure (CPAP) Device |
| Test Firm | DEKRA Testing and Certification, S.A.U. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 699-716 MHz | Original Equipment | 2022-12-30 |
| 2402-2480 MHz | Original Equipment | 2022-12-30 |
| 729-746 MHz | Original Equipment | 2022-12-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| UM | Users Manual | 2023-06-28 | PDF 4.3 MB |
| UM Cellular Addendum | Users Manual | 2023-06-28 | PDF 545.5 KB |
| UM SAR Addendum | Users Manual | 2023-06-28 | PDF 519.1 KB |
| Internal photos | Internal Photos | 2023-06-28 | PDF 708.5 KB |
| External photos | External Photos | 2023-06-28 | PDF 179.2 KB |
| Label | ID Label/Location Info | 2022-12-30 | PDF 1.6 MB |
| Label design | ID Label/Location Info | 2022-12-30 | PDF 1.6 MB |
| 001A1 Test Set up photos | Test Setup Photos | 2023-06-28 | PDF 1.2 MB |
| 002A1 Test Set up photos | Test Setup Photos | 2023-06-28 | PDF 1.2 MB |
| 003A1 Test Set up photos | Test Setup Photos | 2023-06-28 | PDF 1.2 MB |
| 004A1 Test Set up photos | Test Setup Photos | 2023-06-28 | PDF 1.2 MB |
| 6A1 Test Set up photos | Test Setup Photos | 2023-06-28 | PDF 1.3 MB |
| BT LE Test Set up photos | Test Setup Photos | 2023-06-28 | PDF 1.1 MB |
| CAT M1 Test Set up photos | Test Setup Photos | 2023-06-28 | PDF 585.1 KB |
| REM 001 Test Set up photos | Test Setup Photos | 2023-06-28 | PDF 371.5 KB |
| SAR Test Set up photos | Test Setup Photos | 2023-06-28 | PDF 848.8 KB |
| 001A1 Radiated measurements CAT M1 | Test Report | 2022-12-30 | PDF 3 MB |
| 002A1 Radiated measurements CAT M1 | Test Report | 2022-12-30 | PDF 2.7 MB |
| 003A1 Radiated measurements CAT M1 | Test Report | 2022-12-30 | PDF 3.4 MB |
| 004A1 Radiated measurements CAT M1 | Test Report | 2022-12-30 | PDF 2.2 MB |
| 6A1 Simultanoues TX Radiated measurements | Test Report | 2022-12-30 | PDF 2.1 MB |
| Antenna patterns for BT LE Metadata only | Test Report | 2022-12-30 | PDF 965.2 KB |
| Antenna patterns for CAT M1 | Test Report | 2022-12-30 | PDF 2.7 MB |
| BT LE Test report | Test Report | 2022-12-30 | PDF 3.2 MB |
| CAT M1 Test report part 1 | Test Report | 2022-12-30 | PDF 4.6 MB |
| CAT M1 Test report part 2 | Test Report | 2022-12-30 | PDF 4.6 MB |
| CAT M1 Test report part 3 | Test Report | 2022-12-30 | PDF 4.1 MB |
| CAT M1 Test report part 4 | Test Report | 2022-12-30 | PDF 2.2 MB |
| REM 001 Test report | Test Report | 2022-12-30 | PDF 5.4 MB |
| REM001 AC Conducted emission Test report | Test Report | 2022-12-30 | PDF 5.4 MB |
| SAR test report | Test Report | 2022-12-30 | PDF 2.6 MB |
| SAR test report - calibration | Test Report | 2022-12-30 | PDF 4.7 MB |
| Thales Authorisation to use test report | Cover Letter(s) | 2022-12-30 | PDF 175.3 KB |
| Declaration of Equivalence | Attestation Statements | 2022-12-30 | PDF 232.8 KB |
| Integration letter | Attestation Statements | 2022-12-30 | PDF 560.4 KB |
| Similarities and differences | Attestation Statements | 2022-12-30 | PDF 204.7 KB |
| Agent letter | Cover Letter(s) | 2022-12-30 | PDF 467.1 KB |
| Confidentiality letter | Cover Letter(s) | 2022-12-30 | PDF 452.1 KB |
| Similarities and differences | Cover Letter(s) | 2022-12-30 | PDF 204.7 KB |
| AirSense 11 Block Diagram Metadata only | Block Diagram | PDF 430.7 KB | |
| AirSense 11 Block diagram Metadata only | Block Diagram | PDF 430.7 KB | |
| Thales EXS62W Block Diagram Metadata only | Block Diagram | PDF 678.7 KB | |
| AirSense 11 Schematics Metadata only | Schematics | PDF 2.5 MB | |
| Thales EXS62W Schematics Metadata only | Schematics | PDF 148.1 KB | |
| AirSense 11 Antenna gains Metadata only | Operational Description | PDF 592.9 KB | |
| AirSense 11 Op description Metadata only | Operational Description | PDF 5.7 MB | |
| Thales EXS62W Datasheet Metadata only | Operational Description | PDF 2.5 MB | |
| AirSense 11 BOM Metadata only | Parts List/Tune Up Info | PDF 448.3 KB | |
| AirSense 11 PCB BOM Metadata only | Parts List/Tune Up Info | PDF 5.8 MB | |
| AirSense 11 Tune up Metadata only | Parts List/Tune Up Info | PDF 441.2 KB | |
| AirSense 11 Tune up procedure Metadata only | Parts List/Tune Up Info | PDF 822.1 KB | |
| Thales EXS62W BOM Metadata only | Parts List/Tune Up Info | PDF 108.2 KB |
Application Information
| Application ID | zqRANiaeCeDJkYBXHCPmlA== |
|---|---|
| Final Action Date | 2022-12-30 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0023645450 |
| Model | AIR11M1G22 |
| Frequency Range | 699-716 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Continuous Positive Airway Pressure (CPAP) Device |
| Responsible Party | Christopher Jenkins, Associate Manager - Systems Engineering, Christopher.Jenkins@resmed.com.au |
| Agent | Mario Mario Mario, Dekra Testing and Certification SAU, mario.baudet@dekra.com |
| Test Firm | Rafael Lopez Martin, DEKRA Testing and Certification, S.A.U., rafael.lopez@dekra.com |
| TCB Email | admin.rcb.es@dekra.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 06/28/2023 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power is conducted. Multi-transmitter configurations, supporting simultaneous transmission, have been evaluated as described in this filling. Other multi-transmitter configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f), §15.31(h) and §15.31(k) composite system and §2.1 terms and concepts. SAR testing has been performed at a conservative test separation distance of 15 mm. The back face of the device was measured at a minimum test distance of 45 mm due to mains cord. For the PCB equipment class, the highest reported SAR for head, body, and simultaneous transmission exposure conditions are 0.33 W/kg, 0.29 W/kg, and 0.34 W/kg, respectively. For the DTS equipment class, the highest reported estimated SAR and simultaneous transmission exposure conditions are 0.014 W/kg, and 0.34 W/kg, respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| zqRANiaeCeDJkYBXHCPmlA== | 2022-12-30 | Original Equipment |
| oVEDEw2eP3wn6gym9DiWFw== | 2022-12-30 | Original Equipment |
| f3Y0uNwjkwwrMNJnHbMbPw== | 2022-12-30 | Original Equipment |
| S1hTIMNCxr5d/QrL6bZTRA== | 2022-12-30 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 15B | CC | ||||
| 699-716 MHz | 0.08492 | 0.0085ppm | 1M13G7D | 27 | |
| 699-716 MHz | 0.08453 | 0.0085ppm | 970KW7D | 27 | |
| 699-716 MHz | 0.08299 | 0.0085ppm | 990KW7D | 27 | |
| 729-746 MHz | 15B | CC | |||
| 746-756 MHz | 15B | CC | |||
| 777-787 MHz | 0.08414 | 0.0092ppm | 1M13G7D | 27 | |
| 777-787 MHz | 0.08453 | 0.0092ppm | 970KW7D | 27 | |
| 777-787 MHz | 0.07907 | 0.0092ppm | 990KW7D | 27 | |
| 814-824 MHz | 0.08531 | 0.0138ppm | 1M14G7D | 9 | |
| 814-824 MHz | 0.0875 | 0.0138ppm | 980KW7D | 9 | |
| 814-824 MHz | 0.08551 | 0.0138ppm | 1M00W7D | 9 | |
| 824-849 MHz | 0.09484 | 0.0055ppm | 1M15G7D | 22H | |
| 824-849 MHz | 0.09162 | 0.0055ppm | 970KW7D | 22H | |
| 824-849 MHz | 0.06457 | 0.0055ppm | 990KW7D | 22H | |
| 824 MHz | 0.1094 | 0.0138ppm | 1M12G7D | 22H, 9 | |
| 824-849 MHz | 0.08472 | 0.0062ppm | 1M12G7D | 22H | |
| 824-849 MHz | 0.08551 | 0.0062ppm | 990KW7D | 22H | |
| 859-894 MHz | 15B | CC | |||
| 869-894 MHz | 15B | CC | |||
| 1710-1780 MHz | 0.13092 | 0.0045ppm | 1M12G7D | 27 | |
| 1710-1780 MHz | 0.13646 | 0.0045ppm | 1M03W7D | 27 | |
| 1710-1780 MHz | 0.12912 | 0.0045ppm | 1M13G7D | 27 | |
| 1710-1755 MHz | 0.15136 | 0.0025ppm | 1M15G7D | 27 | |
| 1710-1755 MHz | 0.13614 | 0.0025ppm | 940KW7D | 27 | |
| 1710-1755 MHz | 0.13583 | 0.0025ppm | 1M00W7D | 27 | |
| 1850-1915 MHz | 0.14158 | 0.0031ppm | 1M12G7D | 24E | |
| 1850-1915 MHz | 0.139 | 0.0031ppm | 1M03W7D | 24E | |
| 1850-1915 MHz | 0.14028 | 0.0031ppm | 1M13G7D | 24E | |
| 1850-1910 MHz | 0.14256 | 0.0039ppm | 1M15G7D | 24E | |
| 1850-1910 MHz | 0.09772 | 0.0039ppm | 1M87W7D | 24E | |
| 2402-2480 MHz | 0.0010200 | 15C | CC |
Grants
TCB Grant - Application zqRANiaeCeDJkYBXHCPmlA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
DEKRA Testing and Certification, S.A.U. Parque Tecnologico de Andalucia, Calle Severo Ochoa 2 y 6 Campanillas - Malaga, 29590 Spain |
Date of Grant: 12/30/2022 Application Dated: 11/29/2022 |
| ResMed Pty Ltd |
| 1 Elizabeth Macarthur Dr |
| Bella Vista, 2153 Australia |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1G22 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.0 - 1910.0 | 0.14521 | 0.0039 PM | 1M13G7D | |
| 24E | 1850.0 - 1910.0 | 0.15031 | 0.0039 PM | 970KW7D | |
| 24E | 1850.0 - 1910.0 | 0.14256 | 0.0039 PM | 1M15G7D | |
| 24E | 1850.0 - 1910.0 | 0.09772 | 0.0039 PM | 1M87W7D | |
| 27 | 1710.0 - 1755.0 | 0.15136 | 0.0025 PM | 1M15G7D | |
| 27 | 1710.0 - 1755.0 | 0.13614 | 0.0025 PM | 940KW7D | |
| 27 | 1710.0 - 1755.0 | 0.13583 | 0.0025 PM | 1M00W7D | |
| 22H | 824.0 - 849.0 | 0.08472 | 0.0062 PM | 1M12G7D | |
| 22H | 824.0 - 849.0 | 0.08551 | 0.0062 PM | 990KW7D | |
| 27 | 699.0 - 716.0 | 0.08492 | 0.0085 PM | 1M13G7D | |
| 27 | 699.0 - 716.0 | 0.08453 | 0.0085 PM | 970KW7D | |
| 27 | 699.0 - 716.0 | 0.08299 | 0.0085 PM | 990KW7D | |
| 27 | 777.0 - 787.0 | 0.08414 | 0.0092 PM | 1M13G7D | |
| 27 | 777.0 - 787.0 | 0.08453 | 0.0092 PM | 970KW7D | |
| 27 | 777.0 - 787.0 | 0.07907 | 0.0092 PM | 990KW7D | |
| 24E | 1850.0 - 1915.0 | 0.14158 | 0.0031 PM | 1M12G7D | |
| 24E | 1850.0 - 1915.0 | 0.139 | 0.0031 PM | 1M03W7D | |
| 24E | 1850.0 - 1915.0 | 0.14028 | 0.0031 PM | 1M13G7D | |
| 22H | 824.0 - 849.0 | 0.09484 | 0.0055 PM | 1M15G7D | |
| 22H | 824.0 - 849.0 | 0.09162 | 0.0055 PM | 970KW7D | |
| 22H | 824.0 - 849.0 | 0.06457 | 0.0055 PM | 990KW7D | |
| 90 | 814.0 - 824.0 | 0.08531 | 0.0138 PM | 1M14G7D | |
| 90 | 814.0 - 824.0 | 0.0875 | 0.0138 PM | 980KW7D | |
| 90 | 814.0 - 824.0 | 0.08551 | 0.0138 PM | 1M00W7D | |
| 90, 22H | 824.0 - 824.0 | 0.1094 | 0.0138 PM | 1M12G7D | |
| 27 | 1710.0 - 1780.0 | 0.13092 | 0.0045 PM | 1M12G7D | |
| 27 | 1710.0 - 1780.0 | 0.13646 | 0.0045 PM | 1M03W7D | |
| 27 | 1710.0 - 1780.0 | 0.12912 | 0.0045 PM | 1M13G7D |
| Output power is conducted. Multi-transmitter configurations, supporting simultaneous transmission, have been evaluated as described in this filling. Other multi-transmitter configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f), §15.31(h) and §15.31(k) composite system and §2.1 terms and concepts. SAR testing has been performed at a conservative test separation distance of 15 mm. The back face of the device was measured at a minimum test distance of 45 mm due to mains cord. For the PCB equipment class, the highest reported SAR for head, body, and simultaneous transmission exposure conditions are 0.33 W/kg, 0.29 W/kg, and 0.34 W/kg, respectively. For the DTS equipment class, the highest reported estimated SAR and simultaneous transmission exposure conditions are 0.014 W/kg, and 0.34 W/kg, respectively. |
EAS Grant - Application zqRANiaeCeDJkYBXHCPmlA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ResMed Pty Ltd 1 Elizabeth Macarthur Dr Bella Vista, 2153 Australia |
Date of Grant: 12/30/2022 Application Dated: 11/29/2022 |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1G22 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.0 - 1910.0 | 0.14521 | 0.0039 PM | 1M13G7D | |
| 24E | 1850.0 - 1910.0 | 0.15031 | 0.0039 PM | 970KW7D | |
| 24E | 1850.0 - 1910.0 | 0.14256 | 0.0039 PM | 1M15G7D | |
| 24E | 1850.0 - 1910.0 | 0.09772 | 0.0039 PM | 1M87W7D | |
| 27 | 1710.0 - 1755.0 | 0.15136 | 0.0025 PM | 1M15G7D | |
| 27 | 1710.0 - 1755.0 | 0.13614 | 0.0025 PM | 940KW7D | |
| 27 | 1710.0 - 1755.0 | 0.13583 | 0.0025 PM | 1M00W7D | |
| 22H | 824.0 - 849.0 | 0.08472 | 0.0062 PM | 1M12G7D | |
| 22H | 824.0 - 849.0 | 0.08551 | 0.0062 PM | 990KW7D | |
| 27 | 699.0 - 716.0 | 0.08492 | 0.0085 PM | 1M13G7D | |
| 27 | 699.0 - 716.0 | 0.08453 | 0.0085 PM | 970KW7D | |
| 27 | 699.0 - 716.0 | 0.08299 | 0.0085 PM | 990KW7D | |
| 27 | 777.0 - 787.0 | 0.08414 | 0.0092 PM | 1M13G7D | |
| 27 | 777.0 - 787.0 | 0.08453 | 0.0092 PM | 970KW7D | |
| 27 | 777.0 - 787.0 | 0.07907 | 0.0092 PM | 990KW7D | |
| 24E | 1850.0 - 1915.0 | 0.14158 | 0.0031 PM | 1M12G7D | |
| 24E | 1850.0 - 1915.0 | 0.139 | 0.0031 PM | 1M03W7D | |
| 24E | 1850.0 - 1915.0 | 0.14028 | 0.0031 PM | 1M13G7D | |
| 22H | 824.0 - 849.0 | 0.09484 | 0.0055 PM | 1M15G7D | |
| 22H | 824.0 - 849.0 | 0.09162 | 0.0055 PM | 970KW7D | |
| 22H | 824.0 - 849.0 | 0.06457 | 0.0055 PM | 990KW7D | |
| 90 | 814.0 - 824.0 | 0.08531 | 0.0138 PM | 1M14G7D | |
| 90 | 814.0 - 824.0 | 0.0875 | 0.0138 PM | 980KW7D | |
| 90 | 814.0 - 824.0 | 0.08551 | 0.0138 PM | 1M00W7D | |
| 90, 22H | 824.0 - 824.0 | 0.1094 | 0.0138 PM | 1M12G7D | |
| 27 | 1710.0 - 1780.0 | 0.13092 | 0.0045 PM | 1M12G7D | |
| 27 | 1710.0 - 1780.0 | 0.13646 | 0.0045 PM | 1M03W7D | |
| 27 | 1710.0 - 1780.0 | 0.12912 | 0.0045 PM | 1M13G7D |
| Output power is conducted. Multi-transmitter configurations, supporting simultaneous transmission, have been evaluated as described in this filling. Other multi-transmitter configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f), §15.31(h) and §15.31(k) composite system and §2.1 terms and concepts. SAR testing has been performed at a conservative test separation distance of 15 mm. The back face of the device was measured at a minimum test distance of 45 mm due to mains cord. For the PCB equipment class, the highest reported SAR for head, body, and simultaneous transmission exposure conditions are 0.33 W/kg, 0.29 W/kg, and 0.34 W/kg, respectively. For the DTS equipment class, the highest reported estimated SAR and simultaneous transmission exposure conditions are 0.014 W/kg, and 0.34 W/kg, respectively. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
DEKRA Testing and Certification, S.A.U. Parque Tecnologico de Andalucia, Calle Severo Ochoa 2 y 6 Campanillas - Malaga, 29590 Spain |
Date of Grant: 12/30/2022 Application Dated: 12/23/2022 |
| ResMed Pty Ltd |
| 1 Elizabeth Macarthur Dr |
| Bella Vista, 2153 Australia |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1G22 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | Communications Rcvr for use w/ licensed Tx and CBs |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | 869.0 - 894.0 | |||
| CC | 15B | 729.0 - 746.0 | |||
| CC | 15B | 746.0 - 756.0 | |||
| CC | 15B | 859.0 - 894.0 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application S1hTIMNCxr5d/QrL6bZTRA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ResMed Pty Ltd 1 Elizabeth Macarthur Dr Bella Vista, 2153 Australia |
Date of Grant: 12/30/2022 Application Dated: 12/23/2022 |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1G22 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | Communications Rcvr for use w/ licensed Tx and CBs |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | 869.0 - 894.0 | |||
| CC | 15B | 729.0 - 746.0 | |||
| CC | 15B | 746.0 - 756.0 | |||
| CC | 15B | 859.0 - 894.0 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
DEKRA Testing and Certification, S.A.U. Parque Tecnologico de Andalucia, Calle Severo Ochoa 2 y 6 Campanillas - Malaga, 29590 Spain |
Date of Grant: 12/30/2022 Application Dated: 12/23/2022 |
| ResMed Pty Ltd |
| 1 Elizabeth Macarthur Dr |
| Bella Vista, 2153 Australia |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1G22 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | Part 15 Class B Digital Device |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application oVEDEw2eP3wn6gym9DiWFw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ResMed Pty Ltd 1 Elizabeth Macarthur Dr Bella Vista, 2153 Australia |
Date of Grant: 12/30/2022 Application Dated: 12/23/2022 |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1G22 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | Part 15 Class B Digital Device |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
DEKRA Testing and Certification, S.A.U. Parque Tecnologico de Andalucia, Calle Severo Ochoa 2 y 6 Campanillas - Malaga, 29590 Spain |
Date of Grant: 12/30/2022 Application Dated: 12/23/2022 |
| ResMed Pty Ltd |
| 1 Elizabeth Macarthur Dr |
| Bella Vista, 2153 Australia |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1G22 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00102 |
| Output power is conducted. Multi-transmitter configurations, supporting simultaneous transmission, have been evaluated as described in this filling. Other multi-transmitter configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f), §15.31(h) and §15.31(k) composite system and §2.1 terms and concepts. SAR testing has been performed at a conservative test separation distance of 15 mm. The back face of the device was measured at a minimum test distance of 45 mm due to mains cord. For the PCB equipment class, the highest reported SAR for head, body, and simultaneous transmission exposure conditions are 0.33 W/kg, 0.29 W/kg, and 0.34 W/kg, respectively. For the DTS equipment class, the highest reported estimated SAR and simultaneous transmission exposure conditions are 0.014 W/kg, and 0.34 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application f3Y0uNwjkwwrMNJnHbMbPw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ResMed Pty Ltd 1 Elizabeth Macarthur Dr Bella Vista, 2153 Australia |
Date of Grant: 12/30/2022 Application Dated: 12/23/2022 |
| Attention: Christopher Jenkins , Associate Manager - Systems Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ACHL-AIR11M1G22 |
| Name of Grantee: | ResMed Pty Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Continuous Positive Airway Pressure (CPAP) Device |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00102 |
| Output power is conducted. Multi-transmitter configurations, supporting simultaneous transmission, have been evaluated as described in this filling. Other multi-transmitter configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f), §15.31(h) and §15.31(k) composite system and §2.1 terms and concepts. SAR testing has been performed at a conservative test separation distance of 15 mm. The back face of the device was measured at a minimum test distance of 45 mm due to mains cord. For the PCB equipment class, the highest reported SAR for head, body, and simultaneous transmission exposure conditions are 0.33 W/kg, 0.29 W/kg, and 0.34 W/kg, respectively. For the DTS equipment class, the highest reported estimated SAR and simultaneous transmission exposure conditions are 0.014 W/kg, and 0.34 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |