FCC ID 2ACHL-RCM3G

ResMed Connectivity Module

by ResMed Pty Ltd

Grantee Code: 2ACHL   Product Code: RCM3G
Latest application date: 2016-03-17

Device Images

FCC ID Device Details

FCC ID2ACHL-RCM3G
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ACHL
Product CodeRCM3G
Applicant BusinessResMed Pty Ltd 🇦🇺
Related Domains resmed.com.au
Equipment ClassResMed Connectivity Module
Test FirmCETECOM Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2016-03-17

Exhibits

DocumentTypeAvailableFile
regulatory notesUsers Manual2016-09-13PDF 78.8 KB
user guideUsers Manual2016-09-13PDF 394.1 KB
internal photosInternal Photos2016-09-13PDF 890.5 KB
photos moduleInternal Photos2016-09-13PDF 332.4 KB
external photosExternal Photos2016-09-13PDF 505.2 KB
label infoID Label/Location Info2016-03-17PDF 224.3 KB
test set-up photos SARTest Setup Photos2016-09-13PDF 1.2 MB
test set-up photos emcTest Setup Photos2016-09-13PDF 332.4 KB
test report - delta p22&24&27Test Report2016-03-17PDF 1.5 MB
test report - module p22&24Test Report2016-03-17PDF 1.2 MB
test report - module p27Test Report2016-03-17PDF 653.2 KB
attestation reg validity of conducted module test resultsAttestation Statements2016-03-17PDF 223.5 KB
authorization to signCover Letter(s)2016-03-17PDF 89.2 KB
permanent confidentiality requestCover Letter(s)2016-03-17PDF 288.6 KB
temporary confidentiality requestCover Letter(s)2016-03-17PDF 298.3 KB
SAR misc (calibration data etc)RF Exposure Info2016-03-17PDF 2.9 MB
sar plotsRF Exposure Info2016-03-17PDF 870.5 KB
sar reportRF Exposure Info2016-03-17PDF 983.6 KB
block diagram Metadata onlyBlock DiagramPDF 192.7 KB
cellular module block diagram Metadata onlyBlock DiagramPDF 1.4 MB
schematics Metadata onlySchematicsPDF 416.6 KB
antenna details Metadata onlyOperational DescriptionPDF 2 MB
cellular module data sheet Metadata onlyOperational DescriptionPDF 681.9 KB
cellular module technical details Metadata onlyOperational DescriptionPDF 1.6 MB
cellular module technical details & integration Metadata onlyOperational DescriptionPDF 2.3 MB
operational and technical description Metadata onlyOperational DescriptionPDF 545.6 KB
parts list Metadata onlyParts List/Tune Up InfoPDF 432.5 KB
tune-up info Metadata onlyParts List/Tune Up InfoPDF 272.1 KB

Application Information

Application ID1dcUFuk/1wvby2PyQelhgg==
Final Action Date2016-03-17
Application PurposeOriginal Equipment
Applicant FRN0023645450
ModelRCM3G
Frequency Range824.2-848.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionResMed Connectivity Module
Responsible PartyChristopher Jenkins, Associate Manager - Systems Engineering, Christopher.Jenkins@resmed.com.au , +61288841517
Test FirmKevin Wang, CETECOM Inc., kevin.wang@cetecom.com , 408-586-6271
TCB Emailnikolaus.wahl@cetecom.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date09/13/2016
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is ERP for Part 22 and EIRP for Parts 24 and 27. SAR compliance for near the body operation has been assessed for a minimum distance of 20 mm between the device including its antenna and the users body, according to the documented intended purpose. Users must be informed of the operating requirements for satisfying RF exposure compliance. The highest reported SAR for near-the-body (min. 20mm) transmission use conditions is 1.26 W/kg.

Applications

Application IDDatePurpose
1dcUFuk/1wvby2PyQelhgg==2016-03-17Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz2.220.018ppm240KGXW22H
824.2-848.8 MHz0.470.018ppm248KG7W22H
826.4-846.6 MHz0.210.012ppm4M08F9W22H
1712.4-1752.6 MHz0.410.007ppm4M07F9W27
1850.2-1909.8 MHz1.610.012ppm241KGXW24E
1850.2-1909.8 MHz0.660.012ppm252KG7W24E
1852.4-1907.6 MHz0.420.009ppm4M10F9W24E

Grants

TCB Grant - Application 1dcUFuk/1wvby2PyQelhgg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CETECOM Inc.
411 Dixon Landing Road
Milpitas, CA 95035
Date of Grant: 03/17/2016

Application Dated: 03/17/2016
ResMed Pty Ltd
1 Elizabeth Macarthur Dr
Bella Vista, 2153
Australia
 
Attention: Christopher Jenkins , Associate Manager - Systems Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ACHL-RCM3G
Name of Grantee:  ResMed Pty Ltd
Equipment Class: PCS Licensed Transmitter
Notes: ResMed Connectivity Module
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 2.22 0.018  PM 240KGXW
22H 824.2  -  848.8 0.47 0.018  PM 248KG7W
22H 826.4  -  846.6 0.21 0.012  PM 4M08F9W
24E 1850.2  -  1909.8 1.61 0.012  PM 241KGXW
24E 1850.2  -  1909.8 0.66 0.012  PM 252KG7W
24E 1852.4  -  1907.6 0.42 0.009  PM 4M10F9W
27 1712.4  -  1752.6 0.41 0.007  PM 4M07F9W

Output power is ERP for Part 22 and EIRP for Parts 24 and 27.

SAR compliance for near the body operation has been assessed for a minimum distance of 20 mm between the device including its antenna and the users body, according to the documented intended purpose.

Users must be informed of the operating requirements for satisfying RF exposure compliance.

The highest reported SAR for near-the-body (min. 20mm) transmission use conditions is 1.26 W/kg.


EAS Grant - Application 1dcUFuk/1wvby2PyQelhgg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ResMed Pty Ltd
1 Elizabeth Macarthur Dr
Bella Vista, 2153
Australia
  Date of Grant: 03/17/2016

Application Dated: 03/17/2016
 
Attention: Christopher Jenkins , Associate Manager - Systems Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ACHL-RCM3G
Name of Grantee:  ResMed Pty Ltd
Equipment Class: PCS Licensed Transmitter
Notes: ResMed Connectivity Module
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 2.22 0.018  PM 240KGXW
22H 824.2  -  848.8 0.47 0.018  PM 248KG7W
22H 826.4  -  846.6 0.21 0.012  PM 4M08F9W
24E 1850.2  -  1909.8 1.61 0.012  PM 241KGXW
24E 1850.2  -  1909.8 0.66 0.012  PM 252KG7W
24E 1852.4  -  1907.6 0.42 0.009  PM 4M10F9W
27 1712.4  -  1752.6 0.41 0.007  PM 4M07F9W

Output power is ERP for Part 22 and EIRP for Parts 24 and 27.

SAR compliance for near the body operation has been assessed for a minimum distance of 20 mm between the device including its antenna and the users body, according to the documented intended purpose.

Users must be informed of the operating requirements for satisfying RF exposure compliance.

The highest reported SAR for near-the-body (min. 20mm) transmission use conditions is 1.26 W/kg.



Mail To: