FCC ID 2ACV4-UMBRA28-003

Microwave backhaul system

by Cambridge Communications Systems Ltd

Grantee Code: 2ACV4   Product Code: UMBRA28003
Latest application date: 2016-08-22

Device Images

FCC ID Device Details

FCC ID2ACV4-UMBRA28-003
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ACV4
Product CodeUMBRA28003
Applicant BusinessCambridge Communications Systems Ltd 🇬🇧
Related Domains ccsl.com
Equipment ClassMicrowave backhaul system
Test FirmRN Electronics Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
25050-25250 MHzOriginal Equipment2016-08-22

Exhibits

DocumentTypeAvailableFile
External Photographs Metnet v01External Photos2016-08-22PDF 441.8 KB
External photographs High Gain Metnet v01External Photos2016-08-22PDF 361.1 KB
Label locationID Label/Location Info2016-08-22PDF 104.1 KB
Test set up photographsTest Setup Photos2016-08-22PDF 508.5 KB
Test reportTest Report2016-08-22PDF 2.1 MB
Authorisation letterCover Letter(s)2016-08-22PDF 233.6 KB
CCS 2 way NDACover Letter(s)2016-08-22PDF 89.8 KB
Confidentiality requestCover Letter(s)2016-08-22PDF 140 KB
RF Exposure InformationRF Exposure Info2016-08-22PDF 333.6 KB
Users manual high gain Metadata onlyUsers ManualPDF 2.1 MB
Users manual standard Metadata onlyUsers ManualPDF 1.1 MB
Internal photographs Metadata onlyInternal PhotosPDF 1.3 MB
Block diagram Metadata onlyBlock DiagramPDF 23.4 KB
Schematics Metadata onlySchematicsPDF 365.9 KB
Operational description Metadata onlyOperational DescriptionPDF 578.2 KB
Parts list Metadata onlyParts List/Tune Up InfoPDF 37.6 KB
Tune-up procedure Metadata onlyParts List/Tune Up InfoPDF 233 KB

Application Information

Application IDupTxOiRFdntAvOBaf+ntfQ==
Final Action Date2016-08-22
Application PurposeOriginal Equipment
Applicant FRN0023841364
ModelUMBRA28-003
Frequency Range25050-25250 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionMicrowave backhaul system
Responsible PartyMatthew H Lawrence, Mr, mlawrence@ccsl.com , +441223314197
AgentDaniel Daniel Daniel, RN Electronics Ltd, Daniel@RNelectronics.com , +441277352219
Technical ContactPrakritii Gupta, Cambridge Communication Systems Ltd, pgupta@ccsl.com , +441223314197
Non-Technical ContactMatt Edward Rivers-Latham, Cambridge Communication Systems Ltd, mrivers-latham@ccsl.com , +441223347831
Test FirmClint Hilling, RN Electronics Ltd, clint@RNelectronics.com , +44 1277 352219
TCB Emailhotline@acbcert.com
TCB ScopeB4: Microwave, Millimeter Wave Band and Citizens Broadband Radio Services equipment in 47 CFR Parts 25, 30, 74, 90, 95, 96, 97, 101 (all above 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output is conducted at the antenna terminals. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). Rated Output Power: QPSK = 25 dBm 16QAM = 22 dBm 64QAM = 19 dBm

Applications

Application IDDatePurpose
upTxOiRFdntAvOBaf+ntfQ==2016-08-22Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
25050-25250 MHz0.2632.5ppm100MG7D101
25050-25250 MHz0.2692.5ppm50M0G7D101
25050-25250 MHz0.1452.5ppm100MD7D101
25050-25250 MHz0.1512.5ppm50M0D7D101

Grants

TCB Grant - Application upTxOiRFdntAvOBaf+ntfQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 08/22/2016

Application Dated: 08/19/2016
Cambridge Communications Systems Ltd
Victory House, Vision Park,
Chivers Way, Histon
Cambridge, CB24 9ZR
United Kingdom
 
Attention: Matthew Lawrence , Mr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ACV4-UMBRA28-003
Name of Grantee:  Cambridge Communications Systems Ltd
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Microwave backhaul system
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
101 25050.0  -  25250.0 0.263 2.5  PM 100MG7D
101 25050.0  -  25250.0 0.269 2.5  PM 50M0G7D
101 25050.0  -  25250.0 0.145 2.5  PM 100MD7D
101 25050.0  -  25250.0 0.151 2.5  PM 50M0D7D

Power output is conducted at the antenna terminals. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). Rated Output Power: QPSK = 25 dBm 16QAM = 22 dBm 64QAM = 19 dBm

EAS Grant - Application upTxOiRFdntAvOBaf+ntfQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Cambridge Communications Systems Ltd
Victory House, Vision Park, Chivers Way, Histon
Cambridge, CB24 9ZR
United Kingdom
  Date of Grant: 08/22/2016

Application Dated: 08/19/2016
 
Attention: Matthew Lawrence , Mr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ACV4-UMBRA28-003
Name of Grantee:  Cambridge Communications Systems Ltd
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Microwave backhaul system
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
101 25050.0  -  25250.0 0.263 2.5  PM 100MG7D
101 25050.0  -  25250.0 0.269 2.5  PM 50M0G7D
101 25050.0  -  25250.0 0.145 2.5  PM 100MD7D
101 25050.0  -  25250.0 0.151 2.5  PM 50M0D7D

Power output is conducted at the antenna terminals. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). Rated Output Power: QPSK = 25 dBm 16QAM = 22 dBm 64QAM = 19 dBm



Mail To: