FCC ID 2ACZO-USRRELAY

WIFI Remote Control Device

by Jinan USR IOT Technology Limited

Grantee Code: 2ACZO   Product Code: USRRELAY
Latest application date: 2014-10-27

FCC ID Device Details

FCC ID2ACZO-USRRELAY
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ACZO
Product CodeUSRRELAY
Applicant BusinessJinan USR IOT Technology Limited 🇨🇳
Related Domains usr.cn
Equipment ClassWIFI Remote Control Device
Test FirmShenzhen Anbotek Compliance Laboratory Limited

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2014-10-27

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2014-10-27PDF 2.2 MB
Int PhotosInternal Photos2014-10-27PDF 524.3 KB
Ext PhotosExternal Photos2014-10-27PDF 177.6 KB
Label InfoID Label/Location Info2014-10-27PDF 9.1 KB
Label LocationID Label/Location Info2014-10-27PDF 36.2 KB
Test Setup PhotosTest Setup Photos2014-10-27PDF 99.9 KB
Test ReportTest Report2014-10-27PDF 3.3 MB
Confid RequestCover Letter(s)2014-10-27PDF 35.3 KB
RF ExposureRF Exposure Info2014-10-27PDF 39.9 KB
Block Diagram Metadata onlyBlock DiagramPDF 94.2 KB
Schema Metadata onlySchematicsPDF 291.8 KB
Ops Des Metadata onlyOperational DescriptionPDF 37.3 KB

Application Information

Application IDm0P+qtB+N+0v0hzcWnKo2A==
Final Action Date2014-10-27
Application PurposeOriginal Equipment
Applicant FRN0023877897
ModelUSRRELAY
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWIFI Remote Control Device
Responsible PartyGu Xin, General Manager, guxin@usr.cn , 0531-88826739
Technical ContactMark Koop, Teleconformity, mark.koop@teleconformity.com , (31)848395867
Test FirmDaniel zhu, Shenzhen Anbotek Compliance Laboratory Limited, Daniel.zhu@anbotek.com , 86-755-26014771
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is Conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter within a device, except in accordance with accepted multi-transmitter product procedures. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
m0P+qtB+N+0v0hzcWnKo2A==2014-10-27Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.063000015C20

Grants

TCB Grant - Application m0P+qtB+N+0v0hzcWnKo2A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 10/27/2014

Application Dated: 10/24/2014
Jinan USR IOT Technology Limited
11#1103, Building 1, Aosheng Building,
No. 1166 Xinluo Street, Gaoxin Qu,
Jinan, Shandong, 250101
China
 
Attention: Gu Xin , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ACZO-USRRELAY
Name of Grantee:  Jinan USR IOT Technology Limited
Equipment Class: Digital Transmission System
Notes: WIFI Remote Control Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2412.0  -  2462.0 0.063  

Power Output listed is Conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter within a device, except in accordance with accepted multi-transmitter product procedures. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application m0P+qtB+N+0v0hzcWnKo2A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Jinan USR IOT Technology Limited
11#1103, Building 1, Aosheng Building, No. 1166 Xinluo Street, Gaoxin Qu,
Jinan, Shandong, 250101
China
  Date of Grant: 10/27/2014

Application Dated: 10/24/2014
 
Attention: Gu Xin , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ACZO-USRRELAY
Name of Grantee:  Jinan USR IOT Technology Limited
Equipment Class: Digital Transmission System
Notes: WIFI Remote Control Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2412.0  -  2462.0 0.063  

Power Output listed is Conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter within a device, except in accordance with accepted multi-transmitter product procedures. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.