FCC ID 2ADHX-FIDELIORX

Fidelio RX is a wireless audio receiver that delivers descriptive narration for the visually impaired (VI soundtrack), and amplified sound for the hearing impaired (HI soundtrack) in theaters.

by Dolby Laboratories, Inc.

Grantee Code: 2ADHX   Product Code: FIDELIORX
Latest application date: 2014-11-17

FCC ID Device Details

FCC ID2ADHX-FIDELIORX
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ADHX
Product CodeFIDELIORX
Applicant BusinessDolby Laboratories, Inc. 🇺🇸
Related Domains dolby.com doremilabs.com
Equipment ClassFidelio RX is a wireless audio receiver that delivers descriptive narration for the visually impaired (VI soundtrack), and amplified sound for the hearing impaired (HI soundtrack) in theaters.
Test FirmNemko AS

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1921.536-1928.448 MHzOriginal Equipment2014-11-17

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2014-11-17PDF 4.8 MB
Internal PhotosInternal Photos2014-11-17PDF 3.3 MB
External PhotosExternal Photos2014-11-17PDF 2.9 MB
ID LabelID Label/Location Info2014-11-17PDF 84.6 KB
ID Label LocationID Label/Location Info2014-11-17PDF 104 KB
Test Setup PhotosTest Setup Photos2014-11-17PDF 1.1 MB
Test ReportTest Report2014-11-17PDF 1.4 MB
Authorization LetterCover Letter(s)2014-11-17PDF 178.9 KB
Confidentiality RequestCover Letter(s)2014-11-17PDF 40.7 KB
RF Exposure Info 1RF Exposure Info2014-11-17PDF 103.1 KB
RF Exposure Info 2RF Exposure Info2014-11-17PDF 23.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 35.5 KB
Schematics 1 Metadata onlySchematicsPDF 126.7 KB
Schematics 2 Metadata onlySchematicsPDF 700.8 KB
Operational Description Metadata onlyOperational DescriptionPDF 149.5 KB
Parts List 1 Metadata onlyParts List/Tune Up InfoPDF 13.6 KB
Parts List 2 Metadata onlyParts List/Tune Up InfoPDF 7 KB
Tuneup Procedure Metadata onlyParts List/Tune Up InfoPDF 261 KB

Application Information

Application IDpBHWefYbk7QbMvifGU8wNA==
Final Action Date2014-11-17
Application PurposeOriginal Equipment
Applicant FRN0024050585
ModelFIDELIORX
Frequency Range1921.536-1928.448 MHz
Equipment ClassPUT - Part 15 Unlicensed PCS portable Tx worn on body
Device DescriptionFidelio RX is a wireless audio receiver that delivers descriptive narration for the visually impaired (VI soundtrack), and amplified sound for the hearing impaired (HI soundtrack) in theaters.
Responsible PartyOlivier Lambert, Director, Cinema Technology Engineering, olivier.lambert@dolby.com , +1 (818) 524-2970
AgentMichelle Michelle Michelle, CKC Certification Services, LLC, info@ckccertification.com , 209-966-5240
Non-Technical ContactJean-Philippe Viollet, Doremi Labs, jpviollet@doremilabs.com , +1 (818) 562 1101
Test FirmFrode Sveinsen, Nemko AS, frode.sveinsen@nemko.com , 47-22-96-03-35
TCB Emailinfo@ckccertification.com
TCB ScopeA3: Unlicensed Personal Communication System (PCS) devices
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted.

Applications

Application IDDatePurpose
pBHWefYbk7QbMvifGU8wNA==2014-11-17Original Equipment

Equipment Authorization

FrequencyOutputRules
1921.536-1928.448 MHz0.070000015D

Grants

TCB Grant - Application pBHWefYbk7QbMvifGU8wNA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 11/17/2014

Application Dated: 11/14/2014
Dolby Laboratories, Inc.
1020 Chestnut Street
Burbank, CA 91506
 
Attention: Olivier Lambert , Director, Cinema Technology Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADHX-FIDELIORX
Name of Grantee:  Dolby Laboratories, Inc.
Equipment Class: Part 15 Unlicensed PCS portable Tx worn on body
Notes: Fidelio RX is a wireless audio receiver that delivers descriptive narration for the visually impaired (VI soundtrack), and amplified sound for the hearing impaired (HI soundtrack) in theaters.
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15D 1921.536  -  1928.448 0.07  

Power listed is conducted.

EAS Grant - Application pBHWefYbk7QbMvifGU8wNA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Dolby Laboratories, Inc.
1020 Chestnut Street
Burbank, CA 91506
United States
  Date of Grant: 11/17/2014

Application Dated: 11/14/2014
 
Attention: Olivier Lambert , Director, Cinema Technology Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADHX-FIDELIORX
Name of Grantee:  Dolby Laboratories, Inc.
Equipment Class: Part 15 Unlicensed PCS portable Tx worn on body
Notes: Fidelio RX is a wireless audio receiver that delivers descriptive narration for the visually impaired (VI soundtrack), and amplified sound for the hearing impaired (HI soundtrack) in theaters.
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15D 1921.536  -  1928.448 0.07  

Power listed is conducted.



Mail To: