FCC ID 2ADIOEW202W

Smart Light

by Shenzhen Medica Technology Development Co., Ltd.

Grantee Code: 2ADIO   Product Code: EW202W
Latest application date: 2023-04-20

FCC ID Device Details

FCC ID2ADIOEW202W
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ADIO
Product CodeEW202W
Applicant BusinessShenzhen Medica Technology Development Co., Ltd. 🇨🇳
Related Domains sleepace.net
Equipment ClassSmart Light
Test FirmCentre Testing International Group Co., Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2023-04-20
2402-2480 MHzOriginal Equipment2023-04-20

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2023-04-20PDF 2.1 MB
Internal PhotosInternal Photos2023-04-20PDF 1.2 MB
External PhotosExternal Photos2023-04-20PDF 653.5 KB
Label & Label LocationID Label/Location Info2023-04-20PDF 895.2 KB
2.4G WIFI Test Setup PhotosTest Setup Photos2023-04-20PDF 403 KB
BLE Test Setup PhotosTest Setup Photos2023-04-20PDF 400.6 KB
Test Setup PhotosTest Setup Photos2023-04-20PDF 402.3 KB
2.4G WIFI Test ReportTest Report2023-04-20PDF 1.9 MB
2.4G WIFI Test Report AppendixTest Report2023-04-20PDF 4.1 MB
Antenna SpecificationTest Report2023-04-20PDF 812.8 KB
Antenna SpecificationsTest Report2023-04-20PDF 812.8 KB
BLE Test ReportTest Report2023-04-20PDF 1.5 MB
BLE Test Report AppendixTest Report2023-04-20PDF 1.3 MB
Test ReportTest Report2023-04-20PDF 1.8 MB
Test Report AppendixTest Report2023-04-20PDF 5.1 MB
Attestation Statements Part 2.911(d)(5) iAttestation Statements2023-04-20PDF 703.9 KB
Attestation Statements Part 2.911(d)(5) iiAttestation Statements2023-04-20PDF 695 KB
FCC SDOCAttestation Statements2023-04-20PDF 797.1 KB
US Agent LetterAttestation Statements2023-04-20PDF 1.1 MB
Confidentiality LetterCover Letter(s)2023-04-20PDF 954.3 KB
POACover Letter(s)2023-04-20PDF 1,006.7 KB
RF ExposureRF Exposure Info2023-04-20PDF 556.8 KB
Block Diagram Metadata onlyBlock DiagramPDF 6 KB
Schematics Metadata onlySchematicsPDF 146.2 KB
Operation Description Metadata onlyOperational DescriptionPDF 139.2 KB

Application Information

Application IDa3dDpomCj7wxDD1gs/hbYQ==
Final Action Date2023-04-20
Application PurposeOriginal Equipment
Applicant FRN0024055287
ModelEW202W
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSmart Light
Responsible PartyBen Dai, ben@sleepace.net , 8613421320275
Test FirmVicky Zhou, Centre Testing International Group Co., Ltd, zhoushuping@cti-cert.com
TCB EmailTEI@timcoengr.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment, should be installed and operated with a minimum distance of 20 cm between the radiator and your body. Device must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, and 40 MHz bandwidth modes.

Applications

Application IDDatePurpose
a3dDpomCj7wxDD1gs/hbYQ==2023-04-20Original Equipment
QiYfXzF++HJrv+Fja3ircg==2023-04-20Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.001215C
2402-2480 MHz0.002200015C
2412-2462 MHz0.045115C

Grants

TCB Grant - Application QiYfXzF++HJrv+Fja3ircg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 04/20/2023

Application Dated: 04/20/2023
Shenzhen Medica Technology Development Co., Ltd.
12F,Block A,Building 7,Vanke Cloud City,
Xingke 1st Street,Nanshan District,
Shenzhen, 518057
China
 
Attention: Ben Dai

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADIOEW202W
Name of Grantee:  Shenzhen Medica Technology Development Co., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Smart Light
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0022  

Power listed is conducted. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment, should be installed and operated with a minimum distance of 20 cm between the radiator and your body. Device must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application QiYfXzF++HJrv+Fja3ircg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Medica Technology Development Co., Ltd.
12F,Block A,Building 7,Vanke Cloud City, Xingke 1st Street,Nanshan District,
Shenzhen, 518057
China
  Date of Grant: 04/20/2023

Application Dated: 04/20/2023
 
Attention: Ben Dai

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADIOEW202W
Name of Grantee:  Shenzhen Medica Technology Development Co., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Smart Light
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0022  

Power listed is conducted. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment, should be installed and operated with a minimum distance of 20 cm between the radiator and your body. Device must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



TCB Grant - Application a3dDpomCj7wxDD1gs/hbYQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 04/20/2023

Application Dated: 04/20/2023
Shenzhen Medica Technology Development Co., Ltd.
12F,Block A,Building 7,Vanke Cloud City,
Xingke 1st Street,Nanshan District,
Shenzhen, 518057
China
 
Attention: Ben Dai

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADIOEW202W
Name of Grantee:  Shenzhen Medica Technology Development Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Smart Light
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0012  
15C 2412.0  -  2462.0 0.0451  

Power listed is conducted. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment, should be installed and operated with a minimum distance of 20 cm between the radiator and your body. Device must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, and 40 MHz bandwidth modes.

EAS Grant - Application a3dDpomCj7wxDD1gs/hbYQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Medica Technology Development Co., Ltd.
12F,Block A,Building 7,Vanke Cloud City, Xingke 1st Street,Nanshan District,
Shenzhen, 518057
China
  Date of Grant: 04/20/2023

Application Dated: 04/20/2023
 
Attention: Ben Dai

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADIOEW202W
Name of Grantee:  Shenzhen Medica Technology Development Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Smart Light
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0012  
15C 2412.0  -  2462.0 0.0451  

Power listed is conducted. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment, should be installed and operated with a minimum distance of 20 cm between the radiator and your body. Device must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, and 40 MHz bandwidth modes.



Mail To: