FCC ID 2ADIYWP-100
WithaPET is Smart Pet Healthcare Device which can check and monitor pets heart and respiratory rate with smartphone application
by Smartsound Corporation
Grantee Code: 2ADIY Product Code: WP100
Latest application date: 2020-01-16
FCC ID Device Details
| FCC ID | 2ADIYWP-100 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2ADIY |
| Product Code | WP100 |
| Applicant Business | Smartsound Corporation 🇰🇷 |
| Related Domains | |
| Equipment Class | WithaPET is Smart Pet Healthcare Device which can check and monitor pets heart and respiratory rate with smartphone application |
| Test Firm | LTA Co.,Ltd |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2020-01-16 |
| 2402-2480 MHz | Change in identification of presently authorized equipment. Original FCC ID: 2ALGY-NRF52840 Grant Date: 10/26/2018 | 2020-01-10 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2020-07-14 | PDF 1.5 MB |
| internal photos | Internal Photos | 2020-07-14 | PDF 677.7 KB |
| external photos | External Photos | 2020-07-14 | PDF 322.2 KB |
| external photos | External Photos | 2020-07-08 | PDF 297 KB |
| label | ID Label/Location Info | 2020-01-16 | PDF 84.4 KB |
| label&location | ID Label/Location Info | 2020-01-10 | PDF 105.9 KB |
| test setup photos | Test Setup Photos | 2020-07-14 | PDF 361.3 KB |
| test report | Test Report | 2020-01-16 | PDF 1.2 MB |
| POA | Cover Letter(s) | 2020-01-16 | PDF 16.3 KB |
| class II permissive change | Cover Letter(s) | 2020-01-16 | PDF 97.9 KB |
| confidentiality request letter | Cover Letter(s) | 2020-01-16 | PDF 140 KB |
| cover letter | Cover Letter(s) | 2020-01-16 | PDF 84.5 KB |
| POA | Cover Letter(s) | 2020-01-10 | PDF 383 KB |
| change in ID request letter | Cover Letter(s) | 2020-01-10 | PDF 403.3 KB |
| confidentiality request letter | Cover Letter(s) | 2020-01-10 | PDF 88.4 KB |
| cover letter from original applicant | Cover Letter(s) | 2020-01-10 | PDF 456.7 KB |
| block diagram Metadata only | Block Diagram | PDF 41.2 KB | |
| PCB layout schematic diagram Metadata only | Schematics | PDF 109.4 KB | |
| schematic diagram Metadata only | Schematics | PDF 144.5 KB | |
| antenna spec. operation description Metadata only | Operational Description | PDF 124.1 KB | |
| operation description Metadata only | Operational Description | PDF 800.5 KB | |
| part list Metadata only | Parts List/Tune Up Info | PDF 178.2 KB |
Application Information
| Application ID | fnLohd093suh59/S9bJnKg== |
|---|---|
| Final Action Date | 2020-01-16 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0024057770 |
| Model | WP-100 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | WithaPET is Smart Pet Healthcare Device which can check and monitor pets heart and respiratory rate with smartphone application |
| Responsible Party | Jungho Lee, Team Manager, jhojholee@ismartsound.com |
| Test Firm | Ahn Chulho, LTA Co.,Ltd, chahn@ltalab.com |
| TCB Email | TEI@timcoengr.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 07/14/2020 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Single Modular Approval |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. Singular Modular Approval. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific operating instructions for satisfying RF exposure compliance. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. SAR evaluation is valid for mobile applications only (minimum distance of 20cm to human bodies). C2PC: This C2PC is to integrate this module into host device Model: WP-100. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| fnLohd093suh59/S9bJnKg== | 2020-01-16 | Class II permissive change or modification of presently authorized equipment |
| xYD1uXGngYVBOH85ILPJ1w== | 2020-01-10 | Change in identification of presently authorized equipment. Original FCC ID: 2ALGY-NRF52840 Grant Date: 10/26/2018 |
Grants
TCB Grant - Application xYD1uXGngYVBOH85ILPJ1w==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 01/10/2020 Application Dated: 01/10/2020 |
| Smartsound Corporation |
| 4F, 171, Yangjaecheon-ro, Gangnam-gu |
| Seoul, South Korea |
| Attention: Jungho Lee , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ADIYWP-100 |
| Name of Grantee: | Smartsound Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | WithaPET is Smart Pet Healthcare Device which can check and monitor pets heart and respiratory rate with smartphone application |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 41 | 15C | 2402.0 - 2480.0 | 0.00095 |
| Power listed is conducted. Singular Modular Approval. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific operating instructions for satisfying RF exposure compliance. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. SAR evaluation is valid for mobile applications only (minimum distance of 20cm to human bodies). |
| 41: | Installation of this device must not be readily accessible to human subjects closer than 20 cm. |
EAS Grant - Application xYD1uXGngYVBOH85ILPJ1w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Smartsound Corporation 4F, 171, Yangjaecheon-ro, Gangnam-gu Seoul, South Korea |
Date of Grant: 01/10/2020 Application Dated: 01/10/2020 |
| Attention: Jungho Lee , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ADIYWP-100 |
| Name of Grantee: | Smartsound Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | WithaPET is Smart Pet Healthcare Device which can check and monitor pets heart and respiratory rate with smartphone application |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 41 | 15C | 2402.0 - 2480.0 | 0.00095 |
| Power listed is conducted. Singular Modular Approval. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific operating instructions for satisfying RF exposure compliance. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. SAR evaluation is valid for mobile applications only (minimum distance of 20cm to human bodies). |
| 41: | Installation of this device must not be readily accessible to human subjects closer than 20 cm. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 01/16/2020 Application Dated: 01/16/2020 |
| Smartsound Corporation |
| 4F, 171, Yangjaecheon-ro, Gangnam-gu |
| Seoul, South Korea |
| Attention: Jungho Lee , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ADIYWP-100 |
| Name of Grantee: | Smartsound Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | WithaPET is Smart Pet Healthcare Device which can check and monitor pets heart and respiratory rate with smartphone application |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 41 | 15C | 2402.0 - 2480.0 | 0.00095 |
| Power listed is conducted. Singular Modular Approval. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific operating instructions for satisfying RF exposure compliance. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. SAR evaluation is valid for mobile applications only (minimum distance of 20cm to human bodies). C2PC: This C2PC is to integrate this module into host device Model: WP-100. |
| 41: | Installation of this device must not be readily accessible to human subjects closer than 20 cm. |
EAS Grant - Application fnLohd093suh59/S9bJnKg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Smartsound Corporation 4F, 171, Yangjaecheon-ro, Gangnam-gu Seoul, South Korea |
Date of Grant: 01/16/2020 Application Dated: 01/16/2020 |
| Attention: Jungho Lee , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ADIYWP-100 |
| Name of Grantee: | Smartsound Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | WithaPET is Smart Pet Healthcare Device which can check and monitor pets heart and respiratory rate with smartphone application |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 41 | 15C | 2402.0 - 2480.0 | 0.00095 |
| Power listed is conducted. Singular Modular Approval. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific operating instructions for satisfying RF exposure compliance. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. SAR evaluation is valid for mobile applications only (minimum distance of 20cm to human bodies). C2PC: This C2PC is to integrate this module into host device Model: WP-100. |
| 41: | Installation of this device must not be readily accessible to human subjects closer than 20 cm. |
| Mail To: |