FCC ID 2ADLL-1110725
Hardwired Room Sensor
by Broan-NuTone LLC
Grantee Code: 2ADLL Product Code: 1110725
Latest application date: 2023-02-02
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2023-02-02 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2023-08-01 | PDF 366.8 KB |
| Internal Photo | Internal Photos | 2023-08-01 | PDF 5.6 MB |
| External Photo | External Photos | 2023-08-01 | PDF 213.4 KB |
| Label | ID Label/Location Info | 2023-02-02 | PDF 668 KB |
| Label Location | ID Label/Location Info | 2023-02-02 | PDF 18 KB |
| Test Setup Photo | Test Setup Photos | 2023-08-01 | PDF 183.8 KB |
| Test report BLE part 1 | Test Report | 2023-02-02 | PDF 1 MB |
| Test report BLE part 2 | Test Report | 2023-02-02 | PDF 1.1 MB |
| Test report WiFi part 1 | Test Report | 2023-02-02 | PDF 1.2 MB |
| Test report WiFi part 2 | Test Report | 2023-02-02 | PDF 4.5 MB |
| Antenna spec | Cover Letter(s) | 2023-02-02 | PDF 2.6 MB |
| Authorization Letter form | Cover Letter(s) | 2023-02-02 | PDF 123.2 KB |
| Confidential Letter | Cover Letter(s) | 2023-02-02 | PDF 72.6 KB |
| RF Exposure Info | RF Exposure Info | 2023-02-02 | PDF 137.3 KB |
| Block Diagram Metadata only | Block Diagram | PDF 171 KB | |
| Schematics Metadata only | Schematics | PDF 178.9 KB | |
| Operational Description Metadata only | Operational Description | PDF 136.5 KB |
Application Information
| Application ID | XpYP2gqILihVfpVufjcErw== |
|---|---|
| Final Action Date | 2023-02-02 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0024082695 |
| Model | 1110725 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Hardwired Room Sensor |
| Responsible Party | Darren McArthur, Principal Regulatory Engineer, darren.mcarthur@broan.com |
| Test Firm | Robinson Lo, Global United Technology Services Co. Ltd., robinson.lo@gtstest.com |
| TCB Email | darial@compliancetesting.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 08/01/2023 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is conducted. This device has a 20 MHz and 40 MHz bandwidth mode.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| XpYP2gqILihVfpVufjcErw== | 2023-02-02 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application XpYP2gqILihVfpVufjcErw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Compliance Testing, LLC 1724 S. Nevada Way Mesa, AZ 85204 |
Date of Grant: 02/02/2023 Application Dated: 02/02/2023 |
| Broan-NuTone LLC |
| 926 West State Street |
| Hartford, WI 53027 |
| Attention: Darren McArthur , Principal Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ADLL-1110725 |
| Name of Grantee: | Broan-NuTone LLC |
| Equipment Class: | Digital Transmission System |
| Notes: | Hardwired Room Sensor |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.2094112 | |||
| 15C | 2422.0 - 2452.0 | 0.2018366 | |||
| 15C | 2402.0 - 2480.0 | 0.0046345 |
| Power output listed is conducted. This device has a 20 MHz and 40 MHz bandwidth mode.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application XpYP2gqILihVfpVufjcErw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Broan-NuTone LLC 926 West State Street Hartford, WI 53027 United States |
Date of Grant: 02/02/2023 Application Dated: 02/02/2023 |
| Attention: Darren McArthur , Principal Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ADLL-1110725 |
| Name of Grantee: | Broan-NuTone LLC |
| Equipment Class: | Digital Transmission System |
| Notes: | Hardwired Room Sensor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.2094112 | |||
| 15C | 2422.0 - 2452.0 | 0.2018366 | |||
| 15C | 2402.0 - 2480.0 | 0.0046345 |
| Power output listed is conducted. This device has a 20 MHz and 40 MHz bandwidth mode.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |