MO-0026 WIRELESS ARC MOUSE AST Test Report Zeeva International Limited

Zeeva International Limited WIRELESS ARC MOUSE AST

Page 1 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 2 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 3 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 4 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 5 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 6 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 7 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 8 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 9 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 10 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 11 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 12 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 13 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 14 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 15 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 16 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 17 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 18 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 19 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 20 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 21 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 22 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Page 23 of MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited

FCC PART 15.249
TEST REPORT
For
Zeeva International Limited
Suite 1007B, 10th Floor, Exchange Tower, 33 Wang Chiu Road, Kowloon Bay, Hong Kong
FCC ID: 2ADM5-MO-0026
Report Type:
Product Type:
Original Report
WIRELESS ARC MOUSE AST
Report Number: RSZ181026832-00
Report Date:
2018-12-03
Rocky Kang
Reviewed By:
RF Engineer
Prepared By:
Bay Area Compliance Laboratories Corp. (Shenzhen)
6/F., West Wing, Third Phase of Wanli Industrial
Building, Shihua Road, Futian Free Trade Zone,
Shenzhen, Guangdong, China
Tel: +86-755-33320018
Fax: +86-755-33320008
www.baclcorp.com.cn
Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of
the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk
“*”
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
TABLE OF CONTENTS
GENERAL INFORMATION .......................................................................................................................................3
PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
OBJECTIVE ...................................................................................................................................................................3
RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
TEST METHODOLOGY ..................................................................................................................................................3
MEASUREMENT UNCERTAINTY ....................................................................................................................................3
TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
JUSTIFICATION .............................................................................................................................................................5
EUT EXERCISE SOFTWARE ..........................................................................................................................................5
EQUIPMENT MODIFICATIONS .......................................................................................................................................5
SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
SUPPORT CABLE DESCRIPTIONS ...................................................................................................................................5
BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
TEST EQUIPMENT LIST ...........................................................................................................................................8
FCC§15.203 - ANTENNA REQUIREMENT..............................................................................................................9
APPLICABLE STANDARD ..............................................................................................................................................9
ANTENNA CONNECTOR CONSTRUCTION ......................................................................................................................9
FCC§15.205, §15.209 & §15.249(D) - RADIATED EMISSIONS ............................................................................10
APPLICABLE STANDARD ............................................................................................................................................10
TEST EQUIPMENT SETUP ............................................................................................................................................10
EUT SETUP ................................................................................................................................................................11
TEST PROCEDURE ......................................................................................................................................................12
CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................12
TEST RESULTS SUMMARY ..........................................................................................................................................12
TEST DATA ................................................................................................................................................................12
FCC§15.215(C) - 20DB EMISSION BANDWIDTH ................................................................................................21
APPLICABLE STANDARD ............................................................................................................................................21
TEST PROCEDURE ......................................................................................................................................................21
TEST DATA ................................................................................................................................................................21
FCC Part 15.249
Page 2 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The Zeeva International Limited’s product, model number: MO-0026 (FCC ID: 2ADM5-MO-0026, UPC
Number: 192234013960 and 192234015322, SKU Number: 3077690 and 3117132) in this report is a
WIRELESS ARC MOUSE AST, which was measured approximately: 7.6 cm (L) * 5.6 cm (W) * 2.8 cm (H),
rated with input voltage: DC 2 * 1.5 V AAA battery.
Notes: This series products model: MO-0027 and MO-0026 are electrically identical. Model MO-0026 was selected
for fully testing, the detailed information can be referred to the declaration letter.
*All measurement and test data in this report was gathered from production sample serial number: 181026832
(Assigned by BACL,Shenzhen). The EUT supplied by the applicant was received on 2018-10-26.
Objective
This type approval report is prepared on behalf of Zeeva International Limited in accordance with Part 2Subpart J, and Part 15-Subparts A and C of the Federal Communication Commissions rules.
The tests were performed in order to determine compliance with FCC Part 15, Subpart C, and section
15.203, 15.205, 15.209 and 15.249 rules.
Related Submittal(s)/Grant(s)
Submissions with part of a system with FCC ID: 2ADM5-U1.
Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.
All radiated and conducted emissions measurement was performed at Bay Area Compliance Laboratories
Corp. (Shenzhen). The radiated testing was performed at an antenna-to-EUT distance of 3 meters.
Measurement Uncertainty
Parameter
uncertainty
Occupied Channel Bandwidth
±5%
RF Output Power with Power meter
±0.5dB
RF conducted test with spectrum
±1.5dB
Below 1GHz
±4.75dB
Above 1GHz
±4.88dB
All emissions,
radiated
FCC Part 15.249
Temperature
±3℃
Humidity
±6%
Supply voltages
±0.4%
Page 3 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located
on the 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone,
Shenzhen, Guangdong, China.
The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No.: 342867, the FCC Designation No.: CN1221.
The test site has been registered with ISED Canada under ISED Canada Registration Number 3062B.
FCC Part 15.249
Page 4 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
SYSTEM TEST CONFIGURATION
Justification
The system was configured for testing by manufacturer.
8 channels are provided to testing:
Channel
Frequency
(MHz)
2405
2411
2417
2451
Frequency
(MHz)
2457
2463
2469
2475
Channel
Channel 1, Channel 4 and Channel 8 were selected for testing.
EUT Exercise Software
No software was used.
Equipment Modifications
No modifications were made to the unit tested.
Support Equipment List and Details
Manufacturer
Description
Model
Serial Number
N/A
N/A
N/A
N/A
Support Cable Descriptions
FCC Part 15.249
Cable Description
Length (m)
From/Port
To
N/A
N/A
N/A
N/A
Page 5 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
Block Diagram of Test Setup
1.0 Meter
EUT
Non-Conductive Table
80/150 cm above Ground Plane
1.5 Meters
FCC Part 15.249
Page 6 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
SUMMARY OF TEST RESULTS
FCC Rules
Description of Test
Result
§15.203
Antenna Requirement
Compliance
§15.207(a)
Conduction Emissions
Not Applicable
15.205, §15.209, §15.249(d)
Radiated Emissions& Outside
of Band Emission
Compliance
§15.215 (c)
20 dB Bandwidth
Compliance
Not Applicable: The EUT was powered by battery only.
FCC Part 15.249
Page 7 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
TEST EQUIPMENT LIST
Manufacturer
Description
Model
Serial
Number
Calibration
Date
Calibration
Due Date
Radiated Emission Test
A.H. System
Horn Antenna
SAS-200/571
135
2018-09-01
2021-08-31
Rohde & Schwarz
Signal Analyzer
FSEM
845987/005
2018-06-23
2019-06-23
Sunol Sciences
Broadband Antenna
JB1
A040904-1
2017-12-22
2020-12-21
COM-POWER
Pre-amplifier
PA-122
181919
2018-11-22
2019-05-22
Sonoma instrument
Amplifier
310N
186238
2018-11-12
2019-11-12
Rohde & Schwarz
EMI Test Receiver
ESCI
101120
2018-01-11
2019-01-11
RF Cable
UFA147A2362-100100
MFR64639
231029-003
2018-08-01
2019-02-01
RF Cable
104PEA
218124002
2018-11-21
2019-05-21
RF Cable
RG-214
2018-11-19
2019-05-21
RF Cable
RG-214
2018-11-22
2019-05-22
1007726-04
2017-12-29
2020-12-28
15964001002
2018-08-01
2019-02-01
99632
2018-11-21
2019-05-21
Ducommun
technologies
Ducommun
technologies
Ducommun
technologies
Ducommun
technologies
Ducommun
Technologies
Horn Antenna
Heatsink Required
Amplifier
Sinoscite
Band Reject Filter
ARH-422302
QLW18405536-J0
BSF24022480MN0898-001
* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).
FCC Part 15.249
Page 8 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
According to FCC § 15.203, an intentional radiator shall be designed to ensure that no antenna other than
that furnished by the responsible party shall be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this Section. The manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is
prohibited.
Antenna Connector Construction
The EUT has one PCB antenna which was permanently attached and the antenna gain is 0 dBi, fulfill the
requirement of this section. Please refer to the EUT photos.
Result: Compliance.
FCC Part 15.249
Page 9 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
FCC§15.205, §15.209 & §15.249(d) - RADIATED EMISSIONS
Applicable Standard
As per FCC§15.249 (a), except as provided in paragraph (b) of this section, the field strength of
emissions from intentional radiators operated within these frequency bands shall comply with the
following:
Fundamental
frequency
Field strength of fundamental
(millivolts/meter)
Field strength of harmonics
(microvolts/meter)
902–928 MHz
50
500
2400–2483.5 MHz
50
500
5725–5875 MHz
50
500
24.0–24.25 GHz
250
2500
As per FCC§15.249 (c), Field strength limits are specified at a distance of 3 meters.
As per FCC§15.249 (d), Emissions radiated outside of the specified frequency bands, except for
harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general
radiated emission limits in §15.209, whichever is the lesser attenuation.
Test Equipment Setup
The spectrum analyzer or receiver is set as:
Below 1000MHz:
RBW = 100 kHz / VBW = 300 kHz / Sweep = Auto
Above 1000MHz:
Peak: RBW = 1MHz / VBW = 1MHz / Sweep = Auto
Average: RBW = 1MHz / VBW = 10Hz / Sweep = Auto
FCC Part 15.249
Page 10 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
EUT Setup
Below 1GHz:
Above 1GHz:
The radiated emission and out of band emission tests were performed in the 3 meters chamber test site,
using the setup accordance with the ANSI C63.10-2013. The specification used was the FCC
15.209/15.205 and FCC 15.249 limits.
FCC Part 15.249
Page 11 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.
The EUT is set 3 meter away from the testing antenna, which is varied from 1-4 mete, and the EUT is
placed on a turntable, which is 0.8 meter above ground plane for below 1GHz or 1.5 meter for above
1GHz, the table shall be rotated for 360 degrees to find out the highest emission. The receiving antenna
should be changed the polarization both of horizontal and vertical.
Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:
Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain
The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:
Margin = Limit – Corrected Amplitude
Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 15.205, 15.209 &
§15.249
Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if
Lm + U(Lm) ≤ Llim + Ucispr
In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.
Test Data
Environmental Conditions
Temperature:
25 ℃
Relative Humidity:
52 %
ATM Pressure:
101.0 kPa
The testing was performed by Shawn Xiao on 2018-12-01.
Test Mode: Transmitting
FCC Part 15.249
Page 12 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
30MHz – 1 GHz(worst case is middle channel):
80
70
60
Level in dBμV/
Electric Field Strength QP-3m
50
40
30
20
10
30M
50
60
80
100M
200
300
400
500
800
1G
Frequency in Hz
Frequency
(MHz)
Corrected
Amplitude
(dBμV/m)
Antenna
height
(cm)
Antenna
Polarity
Turntable
position
(degree)
Correction
Factor
(dB/m)
Limit
(dBμV/m)
Margin
(dB)
30.301625
14.50
279.0
238.0
-7.8
40.00
25.50
35.469625
11.52
244.0
271.0
-10.8
40.00
28.48
587.087000
20.77
248.0
13.0
-2.6
46.00
25.23
682.833875
21.82
346.0
97.0
-2.0
46.00
24.18
838.374750
30.13
325.0
0.0
5.8
46.00
15.87
957.035375
31.68
201.0
306.0
9.4
46.00
14.32
FCC Part 15.249
Page 13 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
1 GHz - 25 GHz:
Frequency
(MHz)
FCC Part
Rx Antenna Corrected Corrected
15.249&15.209
Turntable
Factor Amplitude
Degree Height Polar
Reading
Limit
Margin
(dB/m) (dBμV/m)
PK/QP/Ave.
(dBμV)
(m) (H/V)
(dBμV/m)
(dB)
Receiver
Low Channel (2405 MHz)
2405.00
41.10
PK
313
1.3
33.00
74.10
114
39.90
2405.00
37.06
Ave.
313
1.3
33.00
70.06
94
23.94
2405.00
38.55
PK
311
1.3
33.00
71.55
114
42.45
2405.00
33.89
Ave.
311
1.3
33.00
66.89
94
27.11
2391.41
27.57
PK
217
2.2
33.00
60.57
74
13.43
2391.41
14.16
Ave.
217
2.2
33.00
47.16
54
6.84
2484.64
27.82
PK
291
1.3
33.20
61.02
74
12.98
2484.64
13.45
Ave.
291
1.3
33.20
46.65
54
7.35
4810.00
55.89
PK
159
2.4
7.88
63.77
74
10.23
4810.00
45.90
Ave.
159
2.4
7.88
53.78
54
0.22
7215.00
43.99
PK
123
2.0
15.88
59.87
74
14.13
7215.00
32.54
Ave.
123
2.0
15.88
48.42
54
5.58
2451.00
41.17
PK
250
2.2
33.10
74.27
114
39.73
2451.00
37.22
Ave.
250
2.2
33.10
70.32
94
23.68
2451.00
40.00
PK
292
2.1
33.10
73.10
114
40.90
2451.00
36.12
Ave.
292
2.1
33.10
69.22
94
24.78
4902.00
53.73
PK
111
1.1
9.21
62.94
74
11.06
4902.00
43.65
Ave.
111
1.1
9.21
52.86
54
1.14
7353.00
45.05
PK
270
1.9
14.69
59.74
74
14.26
7353.00
33.87
Ave.
270
1.9
14.69
48.56
54
5.44
Middle Channel (2451 MHz)
FCC Part 15.249
Page 14 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Frequency
(MHz)
Report No.: RSZ181026832-00
FCC Part
Rx Antenna Corrected Corrected
15.249&15.209
Turntable
Factor Amplitude
Degree Height Polar
Reading
Limit
Margin
(dB/m) (dBμV/m)
PK/QP/Ave.
(dBμV)
(m) (H/V)
(dBμV/m)
(dB)
High Channel (2475 MHz)
Receiver
2475.00
43.07
PK
36
1.7
33.20
76.27
114
37.73
2475.00
39.49
Ave.
36
1.7
33.20
72.69
94
21.31
2475.00
39.56
PK
30
1.5
33.20
72.76
114
41.24
2475.00
35.49
Ave.
30
1.5
33.20
68.69
94
25.31
2399.46
27.97
PK
133
2.5
33.00
60.97
74
13.03
2399.46
14.12
Ave.
133
2.5
33.00
47.12
54
6.88
2483.86
26.89
PK
127
1.1
33.20
60.09
74
13.91
2483.86
13.63
Ave.
127
1.1
33.20
46.83
54
7.17
4950.00
52.39
PK
78
1.2
9.07
61.46
74
12.54
4950.00
41.91
Ave.
78
1.2
9.07
50.98
54
3.02
7425.00
44.34
PK
63
1.5
14.79
59.13
74
14.87
7425.00
31.13
Ave.
63
1.5
14.79
45.92
54
8.08
Note:
Corrected Amplitude = Corrected Factor + Reading
Corrected Factor=Antenna factor (RX) +cable loss – amplifier factor
Margin = Limit- Corr. Amplitude
The emission more than20dB below the limit was not required to be recorded.
FCC Part 15.249
Page 15 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
Pre-scan with middle channel Peak
Horizontal
FCC Part 15.249
Page 16 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
Vertical
FCC Part 15.249
Page 17 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
Average value for the peak point at pre-scan
Horizontal
FCC Part 15.249
Page 18 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
Vertical
FCC Part 15.249
Page 19 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
FCC Part 15.249
Report No.: RSZ181026832-00
Page 20 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
FCC§15.215(c) - 20dB EMISSION BANDWIDTH
Applicable Standard
Intentional radiators operating under the alternative provisions to the general emission limits, as contained
in § 15.217 through 15.257 and in Subpart E of this part, must be designed to ensure that the 20 dB
bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section
under which the equipment operates, is contained within the frequency band designated in the rule section
under which the equipment is operated.
Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect it to
measurement instrument. Then set it to any one convenient frequency within its operating range. Set a
reference level on the measuring instrument equal to the highest peak value.
3. Measure the frequency difference of two frequencies that indicated 20dB bandwidth.
4. Repeat above procedures until all frequencies measured were complete.
Test Data
Environmental Conditions
Temperature:
25 ℃
Relative Humidity:
52 %
101.0 kPa
ATM Pressure:
The testing was performed by Shawn Xiao on 2018-11-28 and 2018-12-01.
Test Mode: Transmitting
Please refer to the following table and plots.
FCC Part 15.249
Channel
Frequency
(MHz)
20dB Bandwidth
(MHz)
Low
2405
2.685
Middle
2451
2.585
High
2475
2.645
Page 21 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
Low Channel
Middle Channel
FCC Part 15.249
Page 22 of 23
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181026832-00
High Channel
***** END OF REPORT *****
FCC Part 15.249
Page 23 of 23
Download: MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Mirror Download [FCC.gov]MO-0026 WIRELESS ARC MOUSE AST Test Report  Zeeva International Limited
Document ID4119789
Application ID4Q0oHiAehrgKRFU+WLINCg==
Document DescriptionTest Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize38.48kB (481056 bits)
Date Submitted2018-12-27 00:00:00
Date Available2018-12-27 00:00:00
Creation Date2018-12-26 10:59:50
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2018-12-26 10:59:50
Document TitleTest Report
Document CreatorPScript5.dll Version 5.2.2
Document Author: SZ8104

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : SZ8104
Create Date                     : 2018:12:26 10:59:50+08:00
Modify Date                     : 2018:12:26 10:59:50+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Format                          : application/pdf
Creator                         : SZ8104
Title                           : Microsoft Word - RSZ181026832-00 FCC Part 15.249 report.doc
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:e2ff1f5a-4642-4825-b244-d7b99ddb1c1c
Instance ID                     : uuid:e68c33fd-a649-42bd-87de-1702b6c4af2d
Page Count                      : 23