FCC ID 2ADT3-BA1000

900 MHz FHSS Transceiver

by Uptime Solutions

Grantee Code: 2ADT3   Product Code: BA1000
Latest application date: 2015-02-24

FCC ID Device Details

FCC ID2ADT3-BA1000
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ADT3
Product CodeBA1000
Applicant BusinessUptime Solutions 🇺🇸
Related Domains uptime-solutions.us
Equipment Class900 MHz FHSS Transceiver
Test FirmCompatible Electronics, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.97-926.27 MHzOriginal Equipment2015-02-24

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2015-02-24PDF 402.4 KB
Internal PhotosInternal Photos2015-02-24PDF 4.9 MB
External PhotosExternal Photos2015-02-24PDF 3.1 MB
FCC ID Label and LocationID Label/Location Info2015-02-24PDF 86.7 KB
Test Setup PhotosTest Setup Photos2015-02-24PDF 1.5 MB
15.31 RequirementsTest Report2015-02-24PDF 7 KB
Duty Cycle InformationTest Report2015-02-24PDF 191.5 KB
Test ReportTest Report2015-02-24PDF 4 MB
Appointment Letter and Anti-Drug Abuse LetterAttestation Statements2015-02-24PDF 264.3 KB
Non-duplicate Submittal LetterAttestation Statements2015-02-24PDF 149.3 KB
Confidentiality Request LetterCover Letter(s)2015-02-24PDF 219.7 KB
CorrespondenceCover Letter(s)2015-02-24PDF 26 KB
FHSS Declaration LetterCover Letter(s)2015-02-24PDF 204.9 KB
Third Party Confidentiality RequestCover Letter(s)2015-02-24PDF 302.1 KB
MPE CalculationsRF Exposure Info2015-02-24PDF 73 KB
Block Diagram - Device Metadata onlyBlock DiagramPDF 242.6 KB
Radio Block Diagram - Third Party Confidentiality Metadata onlyBlock DiagramPDF 309.5 KB
Radio Schematics - Third Party Confidentiality Metadata onlySchematicsPDF 27.6 KB
Schematics Device Metadata onlySchematicsPDF 85.2 KB
Operational Description - Device Metadata onlyOperational DescriptionPDF 242 KB
Radio Operational Description - Third Party Confidentiality Metadata onlyOperational DescriptionPDF 309.5 KB

Application Information

Application IDYD/srbfRNUwHZa02+su/ig==
Final Action Date2015-02-24
Application PurposeOriginal Equipment
Applicant FRN0024136616
ModelBA1000
Frequency Range902.97-926.27 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device Description900 MHz FHSS Transceiver
Responsible PartyJames W Girardeau, CTO-Founder, jgirardeau@uptime-solutions.us , 512-560-0461
AgentKyle Kyle Kyle, Compatible Electronics, Inc., kyle@celectronics.com , 714-579-0500
Technical ContactKyle Fujimoto, Compatible Electronics, Inc., kyle@celectronics.com , 714-579-0500
Test FirmMichael Christensen, Compatible Electronics, Inc., mike@compatible-electronics.com , 714-579-0500
TCB Emailmike@celectronics.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
YD/srbfRNUwHZa02+su/ig==2015-02-24Original Equipment

Equipment Authorization

FrequencyOutputRules
902.97-926.27 MHz0.083907015C

Grants

TCB Grant - Application YD/srbfRNUwHZa02+su/ig==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Compatible Electronics, Inc.
114 Olinda Drive
Brea, CA 92823
Date of Grant: 02/24/2015

Application Dated: 02/24/2015
Uptime Solutions
2520 Longview
Suite 412
Austin, TX 78705
 
Attention: James Girardeau , CTO-Founder

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADT3-BA1000
Name of Grantee:  Uptime Solutions
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: 900 MHz FHSS Transceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.97  -  926.27 0.083907  

Output Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application YD/srbfRNUwHZa02+su/ig==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Uptime Solutions
2520 Longview Suite 412
Austin, TX 78705
United States
  Date of Grant: 02/24/2015

Application Dated: 02/24/2015
 
Attention: James Girardeau , CTO-Founder

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADT3-BA1000
Name of Grantee:  Uptime Solutions
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: 900 MHz FHSS Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.97  -  926.27 0.083907  

Output Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: