Q800PRO THINKWARE DASH CAM Test Report THINKWARE CORPORATION

THINKWARE CORPORATION THINKWARE DASH CAM

Page 1 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 2 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 3 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 4 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 5 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 6 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 7 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 8 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 9 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 10 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 11 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 12 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 13 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 14 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 15 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 16 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 17 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 18 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 19 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 20 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 21 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 22 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Page 23 of Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION

KES Co., Ltd.
Report No.:
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
KES-E2-18T0055-R3
Page (1) of (26)
EMC TEST REPORT
Test Report No.
KES-E2-18T0055-R3
Date of Issue
Dec. 31, 2018
Product name
THINKWARE DASH CAM
Model/Type No.
Q800PRO
Variant Mode
QA100
FCC ID
2ADTG-Q800PRO
Applicant
THINKWARE CORPORATION
Applicant Address
A, 9FL., Samwhan Hipex, 240, Pangyoyeok-ro, Bundang-gu,
Seongnam-si, Gyeonggi-do, South Korea
Manufacturer
THINKWARE CORPORATION
Manufacturer Address
A, 9FL., Samwhan Hipex, 240, Pangyoyeok-ro, Bundang-gu,
Seongnam-si, Gyeonggi-do, South Korea
Equipment authorization :
Supply's Declaration of Conformity
Date of Receipt
Nov. 22, 2018
Test date
Dec. 11, 2018 ~ Dec. 24, 2018
Test Results
In Compliance
Not in Compliance
Tested by
Reviewed by
Mun Hye, Jung
EMC Test Engineer
Dong-Hun, Jang
EMC Technical Manager
This test report is not related to KOLAS.
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
Report No.:
KES-E2-18T0055-R3
Page (2) of (26)
REPORT REVISION HISTORY
Date
Dec. 14, 2018
Dec. 26, 2018
Test Report No.
KES-E2-18T0055
KES-E2-18T0055-R1
Dec. 28, 2018
Dec. 31, 2018
KES-E2-18T0055-R2
KES-E2-18T0055-R3
Revision History
Issued
1.Changed class A to Class B.
2.For above 1GHz test result section,update the
result tables to be in English and also attach the
test plots to the report.
3.The EUT photos deleted. .
4.Added FCC ID.
IC ID was deleted.
Remarks of Conducted Emissions at Mains Power
Ports was revised.
This report shall not be reproduced except in full, without the written approval of
KES Co., Ltd. This document may be altered or revised by KES Co., Ltd. personnel
only, and shall be noted in the revision section of the document. Any alteration of
this document not carried out by KES Co., Ltd. will constitute fraud and shall nullify
the document.
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
Report No.:
KES-E2-18T0055-R3
Page (3) of (26)
TABLE OF CONTENTS
1.0 General Product Description.................................................................................... 4
1.1 Test Voltage & Frequency ....................................................................................... 5
1.2 Variant Model Differences ....................................................................................... 5
1.3 Device Modifications .............................................................................................. 5
1.4 Equipment Under Test ............................................................................................ 5
1.5 Support Equipments .............................................................................................. 5
1.6 External I/O Cabling .............................................................................................. 6
1.7 EUT Operating Mode(s) .......................................................................................... 6
1.8 Configuration ........................................................................................................ 7
1.9 Remarks when standards applied ............................................................................ 8
1.10 Calibration Details of Equipment Used for Measurement .............................................. 8
1.11 Test Facility .......................................................................................................... 8
1.12 Laboratory Accreditations and Listings ..................................................................... 8
2.0 Test Regulations .................................................................................................... 9
2.1 Conducted Emissions at Mains Power Ports ............................................................. 11
2.2 Radiated Electric Field Emissions(Below 1 ㎓) ......................................................... 12
2.3 Radiated Electric Field Emissions(Above 1 ㎓) ......................................................... 13
APPENDIX A – TEST DATA............................................................................................. 14
Conducted Emissions at Mains Power Ports ................................................................ 14
Radiated Electric Field Emissions(Below 1 ㎓) ............................................................ 16
Radiated Electric Field Emissions(Above 1 ㎓) ............................................................
APPENDIX B – Test Setup Photos and Configuration .........................................................
Conducted Voltage Emissions ..................................................................................
Radiated Electric Field Emissions(Below 1 ㎓) ............................................................
Radiated Electric Field Emissions(Above 1 ㎓) ............................................................
18
24
24
25
26
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
1.0
Report No.:
KES-E2-18T0055-R3
Page (4) of (26)
General Product Description
Main Specifications of EUT are:
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
Report No.:
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
1.1
KES-E2-18T0055-R3
Page (5) of (26)
Test Voltage & Frequency
Unless indicated otherwise on the individual data sheet or test results, the test voltage
and frequency was as indicated below.
1.2
Voltage
230 Vac
120 Vac
Frequency
50 Hz
60 Hz
12 Vdc
24 Vdc
PoE
Hz
Variant Model Differences
Add Simple Derivatives
1.3
Device Modifications
Not applicable
1.4
Equipment Under Test
Description
Model Number
Serial Number
Manufacturer
Remarks
THINKWARE DASH
CAM
Q800PRO
THINKWARE
CORPORATION
EUT
Micro SD card
1.5
Support Equipments
Description
Model
Number
Serial Number
Manufacturer
Remarks
THINKWARE
REAR CAM
BCFH-200
THINKWARE
CORPORATION
GPS receiver
THINKWARE
CORPORATION
SmartPhone
SHV-E210L
R33D713KA3F
Samsung Electronics
Co., Ltd.
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
Report No.:
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
1.6
KES-E2-18T0055-R3
Page (6) of (26)
External I/O Cabling
■ WIFI(12 Vdc/24 Vdc) MODE
Start
END
Description
Cable Spec.
I/O Port
Description
I/O Port
Length
Shield
DC IN
DC POWER
DC OUT
2.5
V-IN
THINKWARE
REAR CAM
V-OUT
7.5
GPS
GPS receiver
GPS
5.0
Wireless
Smart Phone
Wireless
Micro SD slot
Micro SD card
Micro SD slot
Wireless Video Baby
Camera
(EUT)
* Unshielded=U, Shielded=S
■ Recording(12 Vdc/24 Vdc) MODE
Start
END
Description
Cable Spec.
I/O Port
Description
I/O Port
Length
Shield
DC IN
DC POWER
DC OUT
2.5
V-IN
THINKWARE
REAR CAM
V-OUT
7.5
GPS
GPS receiver
GPS
5.0
Micro SD slot
Micro SD card
Micro SD slot
THINKWARE DASH
CAM
(EUT)
* Unshielded=U, Shielded=S
1.7
EUT Operating Mode(s)
Test mode
operating
WIFI
(12 Vdc/24 Vdc)
Connect the EUT and SmartPhone wirelessly
and check network status on SmartPhone.
Recording
(12 Vdc/24 Vdc)
1. During the test, the EUT operation was confirmed with REC LED.
2. After the test, it was confirmed that the images of the EUT were
recorded on the Micro SD card.
EUT Test operating S/W
Name
Version
Manufacture Company
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
1.8
Report No.:
KES-E2-18T0055-R3
Page (7) of (26)
Configuration
■ AC Main
□ DC Main
■ WIFI(12 Vdc/24 Vdc) MODE
■ Recording(12 Vdc/24 Vdc) MODE
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
Report No.:
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
1.9
KES-E2-18T0055-R3
Page (8) of (26)
Remarks when standards applied
N/A
1.10 Calibration Details of Equipment Used for Measurement
Test equipment and test accessories are calibrated on regular basis. The maximum
time between calibrations is one year or what is recommended by the manufacturer,
whichever is less.
1.11 Test Facility
The measurement facility is located at 473-21 Gayeo-ro, Yeoju-si, Gyeonggi-do, 12658,
Korea. The sites are constructed in conformance with the requirements of ANSI
C63.4:2014 and CISPR 16-1-4:2012
1.12 Laboratory Accreditations and Listings
Country
KOREA
International
Agency
Scope of Accreditation
Logo
RRA
EMI (3 m & 10 m Semi-Aechoic
Chamber ,
10 m Open Area and conducted test
site)
EMS (ESD, RS, EFT/Burst, Surge, CS,
Magnetic, Dips and interruptions)
KR0100
KOLAS
EMI (3 m & 10 m Semi-Aechoic
Chamber , and conducted test site)
EMS (ESD, RS, EFT/Burst, Surge, CS,
Magnetic, Dips and interruptions)
KT489
USA
FCC
3 m & 10 m Semi-Aechoic Chamber, 10
m Open Area and Conducted test site to
perform FCC Part 15/18 measurements.
KR0100
Canada
ISED
3 m & 10 m Semi-Aechoic Chamber and
Conducted test site
VCCI
Mains Ports Conducted Interference
Measurement, Telecommunication Ports
Conducted Disturbance Measurement
and
Radiation 10 meter site, Facility for
measuring radiated disturbance above 1
㎓
23298-1
JAPAN
Europe
TÜ V SÜ D
EMI (3 m & 10 m Semi-Aechoic
Chamber , 10 m Open Area and
conducted test site)
EMS (ESD, RS, EFT/Burst, Surge, CS,
Magnetic, Dips and interruptions)
R-4308, C-4798,
T-2311, G-914
CARAT 17 07 01633
001
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
2.0
Report No.:
KES-E2-18T0055-R3
Page (9) of (26)
Test Regulations
The emissions tests were performed according to following regulations:
EMC – Directive 2014/30/EU
EN 61000-6-3:2011
EN 61000-6-1:2007
EN 61000-6-4:2007 +A1:2011
EN 61000-6-2:2005
EN 55011:2007 +A1:2010
Group 1
Class A
Group 2
Class B
Class A
Class B
EN 55014-1:2006 +A2:2011
EN 55014-2:1997 +A2:2008
EN 55015:2013
EN 55032:2015
EN 55024:2010
EN 50130-4:2011 +A1:2014
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61326-1:2013
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
VCCI V-3 / 2015.04
Class A
AS/NZS:2013
Class A
Report No.:
KES-E2-18T0055-R3
Page (10) of (26)
Class B
Class B
47 CFR Part 15, Subpart B
CISPR 22:2009 +A1:2010
Class A
Class B
ANSI C63.4-2014
Class A
Class B
CAN/CSA CISPR 22-10
Class A
Class B
ANSI C63.4-2014
Class A
Class B
IC Regulation ICES-003
RE– Directive 2014/53/EU
EN 301 489-1 V1.9.2
Equipment for fixed use
Equipment for vehicular use
Equipment for portable use
EN 301 489-3 V1.6.1
EN 301 489-17 V2.2.1
EN 60945:2002
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
Report No.:
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
2.1
KES-E2-18T0055-R3
Page (11) of (26)
Conducted Emissions at Mains Power Ports
Test Date
N/A
Test Location
Electro wave Shieldroom
Test Equipment
Used
Description
Model Number Manufacturer
Serial
Number
Cal. Due
EMI Test S/W
EMC32
R&S
9.12.00
EMI TEST
RECEIVER
ESR3
R&S
101781
04, 25, 2019
LISN
ENV216
R&S
101787
01, 05, 2019
LISN
ESH2-Z5
R&S
100450
04, 25, 2019
PULSE LIMITER
ESH3-Z2
R&S
101915
11, 26, 2019
Test Conditions
Temperature:
Relative Humidity:
℃
% R.H.
Frequency Range of Measurement
150 ㎑ to 30 ㎒
Instrument Settings
IF Band Width: 9 ㎑
Test Results
The requirements are:
PASS
NOT PASS
NOT APPLICABLE
Remarks
N/A: It is not tested apply because it is powered by DC.
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
Report No.:
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
2.2
KES-E2-18T0055-R3
Page (12) of (26)
Radiated Electric Field Emissions(Below 1 ㎓)
Test Date
Dec. 24, 2018
Test Location
OPEN AREA TEST SITE #2
SEMI ANECHOIC CHAMBER #4(10 m)
Test Equipment
Used
Description
Model Number Manufacturer
Serial
Number
Cal. Due
EMI Test S/W
EP5/RE
TOYO
Corporation
6.0.0
EMI TEST
RECEIVER
ESU26
R&S
100551
04, 11, 2019
AMPLIFIER
SCU 01
R&S
100603
11, 26, 2019
TRILOGBROADBAND
ANTENNA
VULB9163
Schwarzbeck
714
11, 26, 2020
Test Conditions
Temperature:
Relative Humidity:
21,0 ℃
50,5 % R.H.
Frequency Range of Measurement
30 ㎒ to 1 ㎓
Instrument Settings
IF Band Width: 120 ㎑
Test Results
The requirements are:
PASS
NOT PASS
NOT APPLICABLE
Remarks
See Appendix A for test data.
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
Report No.:
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
2.3
KES-E2-18T0055-R3
Page (13) of (26)
Radiated Electric Field Emissions(Above 1 ㎓)
Test Date
Dec. 11, 2018
Test Location
SEMI ANECHOIC CHAMBER #4(10 m)
Test Equipment
Used
Description
Model Number Manufacturer
Serial
Number
Cal. Due
EMI Test S/W
EP5/RE
TOYO
Corporation
6.0.0
EMI TEST
RECEIVER
ESU26
R&S
100551
04, 11, 2019
PREAMPLIFIER
8449B
AGILENT
ATTENUATOR
8491A
HP
HORN ANTENNA
BBHA 9120D
SCHWARZBECK
3008A01742 01, 11, 2019
35496
03, 21, 2019
9120D-1802 03, 12, 2020
Test Conditions
Temperature:
Relative Humidity:
20,7 ℃
50,6 % R.H.
Frequency Range of Measurement
1 ㎓ to 12 ㎓
Instrument Settings
IF Band Width: 1 ㎒
Test Results
The requirements are:
PASS
NOT PASS
NOT APPLICABLE
Remarks
See Appendix A for test data.
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
Report No.:
KES-E2-18T0055-R3
Page (14) of (26)
APPENDIX A – TEST DATA
Conducted Emissions at Mains Power Ports
HOT LINE
N/A
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
Report No.:
KES-E2-18T0055-R3
Page (15) of (26)
NEUTRAL LINE
N/A
♦ Calculation
QuasiPeak[㏈uV] / CAverage [㏈uV] = Reading Value[㏈uV] + Corr. [㏈]
QuasiPeak / CAverage : The Final Value
Reading Value : Not shown in the table.
Corr. : Correction values (LISN FACTOR + (Cable Loss + Pulse Limiter FACTOR))
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
Report No.:
KES-E2-18T0055-R3
Page (16) of (26)
Radiated Electric Field Emissions(Below 1 ㎓)
■ WIFI 12 Vdc
■ WIFI 24 Vdc
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
Report No.:
KES-E2-18T0055-R3
Page (17) of (26)
■ Recording 12 Vdc
■ Recording 24 Vdc
♦ Calculation – SAC #4(10 m)
Result(QP) [㏈(㎶/m)] = (Reading(QP)[㏈(㎶)] + c.f[㏈(1/m)]
Margin(QP)[㏈] = Limit[㏈(㎶/m)] - Result(QP) [㏈(㎶/m)]
Reading(QP) : Reading value, Result(QP) : Reading value + Factor value
Limit(QP) : Limit value, c.f : (ANT Factor + Cable Loss - Preamp Factor), Margin: Margin value
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
Report No.:
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
KES-E2-18T0055-R3
Page (18) of (26)
Radiated Electric Field Emissions(Above 1 ㎓)
■ WIFI 12 Vdc
(1–5) ㎓
PK
Frequency
[㎒]
Reading
[㏈㎶]
Pol
ari
zat
ion
Antenna
Hight
Factor value
[m]
Antenna
[㏈/m]
Cable
[㏈]
AMP
Factor
(dB)
Result
Limit
[㏈㎶/m]
[㏈㎶/m]
Margin
[㏈]
501.000
44.880
1.240
25.160
9.120
37.360
41.800
74.000
32.200
639.000
43.480
3.590
25.840
9.530
37.350
41.500
74.000
32.500
185.000
38.640
0.000
28.070
11.070
37.580
40.200
74.000
33.800
469.000
30.770
1.000
30.960
13.950
37.880
37.800
74.000
36.200
Pol
ari
zat
ion
Antenna
Hight
AMP
Factor
(dB)
Result
Limit
[㏈㎶/m]
[㏈㎶/m]
AV
Frequency
[㎒]
Reading
[㏈㎶]
Factor value
[m]
Antenna
[㏈/m]
Cable
[㏈]
Margin
[㏈]
501.000
44.880
1.240
25.160
9.120
37.360
41.800
74.000
32.200
639.000
43.480
3.590
25.840
9.530
37.350
41.500
74.000
32.500
185.000
38.640
0.000
28.070
11.070
37.580
40.200
74.000
33.800
469.000
30.770
1.000
30.960
13.950
37.880
37.800
74.000
36.200
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
Report No.:
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
KES-E2-18T0055-R3
Page (19) of (26)
■ WIFI 24 Vdc
(1–5) ㎓
PK
Frequency
[㎒]
Reading
[㏈㎶]
Pol
ari
zat
ion
Antenna
Hight
Factor value
[m]
Antenna
[㏈/m]
Cable
[㏈]
AMP
Factor
(dB)
Result
Limit
[㏈㎶/m]
[㏈㎶/m]
Margin
[㏈]
501.000
44.880
1.240
25.160
9.120
37.360
41.800
74.000
32.200
639.000
43.480
3.590
25.840
9.530
37.350
41.500
74.000
32.500
185.000
38.640
0.000
28.070
11.070
37.580
40.200
74.000
33.800
469.000
30.770
1.000
30.960
13.950
37.880
37.800
74.000
36.200
Pol
ari
zat
ion
Antenna
Hight
AMP
Factor
(dB)
Result
Limit
[㏈㎶/m]
[㏈㎶/m]
AV
Frequency
[㎒]
Reading
[㏈㎶]
Factor value
[m]
Antenna
[㏈/m]
Cable
[㏈]
Margin
[㏈]
501.000
44.880
1.240
25.160
9.120
37.360
41.800
74.000
32.200
639.000
43.480
3.590
25.840
9.530
37.350
41.500
74.000
32.500
185.000
38.640
0.000
28.070
11.070
37.580
40.200
74.000
33.800
469.000
30.770
1.000
30.960
13.950
37.880
37.800
74.000
36.200
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
Report No.:
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
KES-E2-18T0055-R3
Page (20) of (26)
■ Recording 12 Vdc
(1–5) ㎓
PK
Frequency
[㎒]
Reading
[㏈㎶]
Pol
ari
zat
ion
Antenna
Hight
Factor value
[m]
Antenna
[㏈/m]
Cable
[㏈]
AMP
Factor
(dB)
Result
Limit
[㏈㎶/m]
[㏈㎶/m]
Margin
[㏈]
501.000
44.880
1.240
25.160
9.120
37.360
41.800
74.000
32.200
639.000
43.480
3.590
25.840
9.530
37.350
41.500
74.000
32.500
185.000
38.640
0.000
28.070
11.070
37.580
40.200
74.000
33.800
469.000
30.770
1.000
30.960
13.950
37.880
37.800
74.000
36.200
Pol
ari
zat
ion
Antenna
Hight
AMP
Factor
(dB)
Result
Limit
[㏈㎶/m]
[㏈㎶/m]
AV
Frequency
[㎒]
Reading
[㏈㎶]
Factor value
[m]
Antenna
[㏈/m]
Cable
[㏈]
Margin
[㏈]
501.000
44.880
1.240
25.160
9.120
37.360
41.800
74.000
32.200
639.000
43.480
3.590
25.840
9.530
37.350
41.500
74.000
32.500
185.000
38.640
0.000
28.070
11.070
37.580
40.200
74.000
33.800
469.000
30.770
1.000
30.960
13.950
37.880
37.800
74.000
36.200
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
Report No.:
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
KES-E2-18T0055-R3
Page (21) of (26)
■ Recording 24 Vdc
(1–5) ㎓
PK
Frequency
[㎒]
Reading
[㏈㎶]
Pol
ari
zat
ion
Antenna
Hight
Factor value
[m]
Antenna
[㏈/m]
Cable
[㏈]
AMP
Factor
(dB)
Result
Limit
[㏈㎶/m]
[㏈㎶/m]
Margin
[㏈]
501.000
44.880
1.240
25.160
9.120
37.360
41.800
74.000
32.200
639.000
43.480
3.590
25.840
9.530
37.350
41.500
74.000
32.500
185.000
38.640
0.000
28.070
11.070
37.580
40.200
74.000
33.800
469.000
30.770
1.000
30.960
13.950
37.880
37.800
74.000
36.200
Pol
ari
zat
ion
Antenna
Hight
AMP
Factor
(dB)
Result
Limit
[㏈㎶/m]
[㏈㎶/m]
AV
Frequency
[㎒]
Reading
[㏈㎶]
Factor value
[m]
Antenna
[㏈/m]
Cable
[㏈]
Margin
[㏈]
501.000
44.880
1.240
25.160
9.120
37.360
41.800
74.000
32.200
639.000
43.480
3.590
25.840
9.530
37.350
41.500
74.000
32.500
185.000
38.640
0.000
28.070
11.070
37.580
40.200
74.000
33.800
469.000
30.770
1.000
30.960
13.950
37.880
37.800
74.000
36.200
Exclusion Band: 2.4 ㎓
♦ Calculation
Result(PK/CAV) [㏈(㎶/m)] = (Reading(PK/CAV)[㏈(㎶)] + c.f[㏈(1/m)]
Margin(PK/CAV)[㏈] = Limit[㏈(㎶/m)] - Result(PK/CAV) [㏈(㎶/m)]
Reading(PK/CAV) : Reading value, Result(PK/CAV) : Reading value + Factor value
Limit(QP) : Limit value, c.f : (ANT Factor + Cable Loss - Preamp Factor), Margin: Margin value
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
Report No.:
KES-E2-18T0055-R3
Page (22) of (26)
■ WIFI 12 Vdc
( 5 – 12 ) ㎓
■ WIFI 24 Vdc
( 5 – 12 ) ㎓
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
KES Co., Ltd.
3701, 40, Simin-daero 365beon-gil,
Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Korea
Tel: +82-31-425-6200 / Fax: +82-31-424-0450
www.kes.co.kr
Report No.:
KES-E2-18T0055-R3
Page (23) of (26)
■ Recording 12 Vdc
( 5 – 12 ) ㎓
■ Recording 24 Vdc
( 5 – 12 ) ㎓
(5 – 12) ㎓: No spurious emission were detected above 5 ㎓.
This report shall not be reproduced except in full, without the written approval of KES Co., Ltd.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
The authenticity of the test report, contact shchoi@kes.co.kr
KES-P-5101-14 Rev. 5
KES
A4
Download: Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Mirror Download [FCC.gov]Q800PRO THINKWARE DASH CAM Test Report  THINKWARE CORPORATION
Document ID4125434
Application IDGi9cIaaiyu8dMAgyZqRVsQ==
Document DescriptionTest report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize95.06kB (1188202 bits)
Date Submitted2018-12-30 00:00:00
Date Available2018-12-30 00:00:00
Creation Date2019-01-02 11:06:56
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2019-01-02 11:09:46
Document TitleTest report
Document CreatorMicrosoft® Word 2010
Document Author: KES

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : KES
Create Date                     : 2019:01:02 11:06:56+09:00
Modify Date                     : 2019:01:02 11:09:46+09:00
Has XFA                         : No
Language                        : ko-KR
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Format                          : application/pdf
Creator                         : KES
Creator Tool                    : Microsoft® Word 2010
Metadata Date                   : 2019:01:02 11:09:46+09:00
Producer                        : Microsoft® Word 2010
Document ID                     : uuid:1c39ff67-685c-47ff-b9b8-abbb416fcfa2
Instance ID                     : uuid:36ec1bf9-07fa-4cae-80c6-26126ef98610
Page Count                      : 23