FCC ID 2ADTK-FBT0002100

Indoor Air Quality Sensor

by Airboxlab S.A.

Grantee Code: 2ADTK   Product Code: FBT0002100
Latest application date: 2015-07-27

FCC ID Device Details

FCC ID2ADTK-FBT0002100
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ADTK
Product CodeFBT0002100
Applicant BusinessAirboxlab S.A. 🇱🇺
Related Domains airboxlab.com
Equipment ClassIndoor Air Quality Sensor
Test FirmAccurate Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2015-07-27

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2015-07-27PDF 2.4 MB
Int photoInternal Photos2015-07-27PDF 541.5 KB
Ext photoExternal Photos2015-07-27PDF 405.1 KB
LabelID Label/Location Info2015-07-27PDF 68.9 KB
Test photosTest Setup Photos2015-07-27PDF 99.8 KB
WIFI test report part 1Test Report2015-07-27PDF 4.4 MB
WIFI test report part 2Test Report2015-07-27PDF 4.2 MB
Confidential request letterCover Letter(s)2015-07-27PDF 23.7 KB
POACover Letter(s)2015-07-27PDF 23.7 KB
WiFi ch 12 13Cover Letter(s)2015-07-27PDF 43.9 KB
RF ExposureRF Exposure Info2015-07-27PDF 88.9 KB
Block diagram Metadata onlyBlock DiagramPDF 116 KB
SCH Metadata onlySchematicsPDF 272.5 KB
OpDes Metadata onlyOperational DescriptionPDF 78.4 KB

Application Information

Application IDfnC25Gtm6AlK++5d05GxKQ==
Final Action Date2015-07-27
Application PurposeOriginal Equipment
Applicant FRN0024152217
ModelFBT0002100
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionIndoor Air Quality Sensor
Responsible PartyInouk Bourgon, Chief technical officer, inouk@airboxlab.com , +352545580290
Test FirmSean Liu, Accurate Technology Co., Ltd., sean@atc-lab.com , 86-755-26503291
TCB EmailTCB@siemic.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is the maximum conducted output power. Device contains 20 and 40 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance

Applications

Application IDDatePurpose
fnC25Gtm6AlK++5d05GxKQ==2015-07-27Original Equipment

Equipment Authorization

FrequencyOutputRules
2412-2462 MHz0.051000015C

Grants

TCB Grant - Application fnC25Gtm6AlK++5d05GxKQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 07/27/2015

Application Dated: 07/26/2015
Airboxlab S.A.
3 av du blues,
Sanem, 4368
Luxembourg
 
Attention: Inouk Bourgon , Chief technical officer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADTK-FBT0002100
Name of Grantee:  Airboxlab S.A.
Equipment Class: Digital Transmission System
Notes: Indoor Air Quality Sensor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.051  

Power listed is the maximum conducted output power.

Device contains 20 and 40 MHz signal bandwidth.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance


EAS Grant - Application fnC25Gtm6AlK++5d05GxKQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Airboxlab S.A.
3 av du blues,
Sanem, 4368
Luxembourg
  Date of Grant: 07/27/2015

Application Dated: 07/26/2015
 
Attention: Inouk Bourgon , Chief technical officer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADTK-FBT0002100
Name of Grantee:  Airboxlab S.A.
Equipment Class: Digital Transmission System
Notes: Indoor Air Quality Sensor
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.051  

Power listed is the maximum conducted output power.

Device contains 20 and 40 MHz signal bandwidth.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance



Mail To: