FCC ID 2ADXK-8626

Blood Pressure Monitor

by Shenzhen Viatom Technology Co., Ltd.

Grantee Code: 2ADXK   Product Code: 8626
Latest application date: 2026-08-17

FCC ID Device Details

FCC ID2ADXK-8626
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ADXK
Product Code8626
Applicant BusinessShenzhen Viatom Technology Co., Ltd. 🇨🇳
Related Domains viatomtech.com fccusagent.com
Equipment ClassBlood Pressure Monitor
Test FirmCentre Testing International Group Co., Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2026-08-17

Exhibits

DocumentTypeAvailableFile
Label & LocationID Label/Location Info2026-08-17PDF 162.8 KB
15.247 2.4G WIFI report 1Test Report2026-08-17PDF 5.2 MB
15.247 2.4G WIFI report 2Test Report2026-08-17PDF 5.5 MB
15.247 2.4G WIFI report 3Test Report2026-08-17PDF 5.2 MB
15.247 2.4G WIFI report 4Test Report2026-08-17PDF 5.2 MB
15.247 2.4G WIFI report 5Test Report2026-08-17PDF 2 MB
15.247 Bluetooth LE reportTest Report2026-08-17PDF 231.5 KB
15.247 Bluetooth LE report 1Test Report2026-08-17PDF 5.4 MB
15.247 Bluetooth LE report 2Test Report2026-08-17PDF 5.5 MB
Antenna SpecificationTest Report2026-08-17PDF 854.6 KB
Appendix 2.4G WIFI 1Test Report2026-08-17PDF 5.2 MB
Appendix 2.4G WIFI 2Test Report2026-08-17PDF 5.1 MB
Appendix 2.4G WIFI 3Test Report2026-08-17PDF 5.4 MB
Appendix 2.4G WIFI 4Test Report2026-08-17PDF 2.2 MB
Appendix Bluetooth LE 1Test Report2026-08-17PDF 5.5 MB
Appendix Bluetooth LE 2Test Report2026-08-17PDF 2.8 MB
wifi Antenna SpecificationTest Report2026-08-17PDF 591.1 KB
Attestation Statements Part 2.911 i iiAttestation Statements2026-08-17PDF 97.9 KB
Attestation Statements US agent for service of processAttestation Statements2026-08-17PDF 168.3 KB
Confidentiality LetterCover Letter(s)2026-08-17PDF 89.7 KB
POACover Letter(s)2026-08-17PDF 52.9 KB
models declaration letterCover Letter(s)2026-08-17PDF 94.9 KB
Appendix A SAR System performance Check PlotsRF Exposure Info2026-08-17PDF 540.2 KB
Appendix B SAR Measurement results PlotsRF Exposure Info2026-08-17PDF 541.4 KB
Appendix C Calibration reports 1RF Exposure Info2026-08-17PDF 4.7 MB
Appendix C Calibration reports 2RF Exposure Info2026-08-17PDF 5.3 MB
Appendix C Calibration reports 3RF Exposure Info2026-08-17PDF 206.3 KB
Tablet SAR ReportRF Exposure Info2026-08-17PDF 1.5 MB
User Manual Metadata onlyUsers Manual2027-02-14PDF 1 MB
Internal Photos Metadata onlyInternal Photos2027-02-14PDF 4 MB
External Photos Metadata onlyExternal Photos2027-02-14PDF 1.1 MB
Appendix D Photo Metadata onlyTest Setup Photos2027-02-14PDF 1.6 MB
Test Setup Photos Metadata onlyTest Setup Photos2027-02-14PDF 4.3 MB
Block Diagram Metadata onlyBlock DiagramPDF 308.7 KB
Schematics Metadata onlySchematicsPDF 230.8 KB
Schematics WIFI module Metadata onlySchematicsPDF 141.3 KB
Operational Description Metadata onlyOperational DescriptionPDF 165 KB
Operation Description Metadata onlyParts List/Tune Up InfoPDF 165 KB

Application Information

Application IDfK0kde5nASpIH41iigncRg==
Final Action Date2026-08-17
Application PurposeOriginal Equipment
Applicant FRN0024194888
Model8626
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionBlood Pressure Monitor
Responsible PartyBing Wang, wangbing@viatomtech.com , +8675586638929
Non-Technical ContactTim Payne, FCC US Agent, LLC, Support@FCCUSAgent.com , 708-571-3148
Test FirmVicky Zhou, Centre Testing International Group Co., Ltd, zhoushuping@cti-cert.com , 86-755-3368-1398
TCB EmailCB@industrial-ia.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
fK0kde5nASpIH41iigncRg==2026-08-17Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.001215C
2412-2462 MHz0.009215C

Grants

TCB Grant - Application fK0kde5nASpIH41iigncRg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 08/17/2026

Application Dated: 08/17/2026
Shenzhen Viatom Technology Co., Ltd.
901, Building West, Lepu Tower, No.66 Xingke
Road, Xili Community, Xili Street, Nanshan
District, Shenzhen, 518055, Guangdong, P.R., 518055
China
 
Attention: Bing Wang , Manager of R&D

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADXK-8626
Name of Grantee:  Shenzhen Viatom Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Blood Pressure Monitor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0012  
15C 2412.0  -  2462.0 0.0092  

Output Power listed is the maximum conducted output power. The highest reported SAR for body-worn accessory, and simultaneous transmission exposure conditions are <0.10 W/kg, 0.10 W/kg. This device supports 20 MHz bandwidth modes.