FCC ID 2ADYL-JPD500F

pulse oximeter

by ShenZhen Jumper Medical Equipment Co.,Ltd

Grantee Code: 2ADYL   Product Code: JPD500F
Latest application date: 2015-05-06

FCC ID Device Details

FCC ID2ADYL-JPD500F
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ADYL
Product CodeJPD500F
Applicant BusinessShenZhen Jumper Medical Equipment Co.,Ltd 🇨🇳
Related Domains jumper-medical.com
Equipment Classpulse oximeter
Test FirmIntertek Testing Services Shenzhen Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2015-05-06

Exhibits

DocumentTypeAvailableFile
141212001GZU-001_User manualUsers Manual2015-05-06PDF 513.6 KB
141212001GZU-001_Internal photo_rev1Internal Photos2015-05-06PDF 381.2 KB
141212001GZU-001_External photo_rev1External Photos2015-05-06PDF 1.6 MB
141212001GZU-001_LabelID Label/Location Info2015-05-06PDF 399.6 KB
141212001GZU-001_Block diagramBlock Diagram2015-05-06PDF 4.2 KB
141212001GZU-001_Block diagram_rev2Block Diagram2015-05-06PDF 28.4 KB
141212001GZU-001_SchematicSchematics2015-05-06PDF 74.9 KB
141212001GZU_Schematics_rev2Schematics2015-05-06PDF 46.1 KB
141212001GZU-001_Technical description_rev2Operational Description2015-05-06PDF 6.3 KB
cc2540 datasheet rev-F(2013-06)Operational Description2015-05-06PDF 662 KB
141212001GZU-001_Test setup photoTest Setup Photos2015-05-06PDF 159 KB
141212001GZU-001_Test report_rev2Test Report2015-05-06PDF 1.2 MB
141212001GZU-001_Authorization letterCover Letter(s)2015-05-06PDF 768.4 KB
141212001GZU-RF ExposureRF Exposure Info2015-05-06PDF 21.9 KB

Application Information

Application IDHeORqGog/dRrvOvKFdmHYQ==
Final Action Date2015-05-06
Application PurposeOriginal Equipment
Applicant FRN0024203473
ModelJPD500F
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device Descriptionpulse oximeter
Responsible PartyVicky Wang, RA Manager, vicky.wang@jumper-medical.com , 86-755-26696279
AgentJohn John John, Intertek Testing Services Shenzhen Ltd. Guangzhou, John.meng@intertek.com , 86-20-82139718
Technical ContactJohn Meng, Intertek Testing Services Shenzhen Ltd. Guangzhou, john.meng@intertek.com , 86-20-82139718
Test Firmstrong yao, Intertek Testing Services Shenzhen Ltd., strong.yao@intertek.com , 8628219940
TCB Emailhotline@acbcert.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is conducted. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
HeORqGog/dRrvOvKFdmHYQ==2015-05-06Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.000995015C

Grants

TCB Grant - Application HeORqGog/dRrvOvKFdmHYQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 05/06/2015

Application Dated: 05/06/2015
ShenZhen Jumper Medical Equipment Co.,Ltd
D Building, No. 71, Xintian Road, Fuyong Street,
Baoan,Shenzhen, Guangdong,China
ShenZhen, 518103
China
 
Attention: Vicky Wang , RA Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADYL-JPD500F
Name of Grantee:  ShenZhen Jumper Medical Equipment Co.,Ltd
Equipment Class: Digital Transmission System
Notes: pulse oximeter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.000995  

Power Output listed is conducted. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application HeORqGog/dRrvOvKFdmHYQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ShenZhen Jumper Medical Equipment Co.,Ltd
D Building, No. 71, Xintian Road, Fuyong Street, Baoan,Shenzhen, Guangdong,China
ShenZhen, 518103
China
  Date of Grant: 05/06/2015

Application Dated: 05/06/2015
 
Attention: Vicky Wang , RA Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADYL-JPD500F
Name of Grantee:  ShenZhen Jumper Medical Equipment Co.,Ltd
Equipment Class: Digital Transmission System
Notes: pulse oximeter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.000995  

Power Output listed is conducted. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.