CX Mobile phone Test Report Measurement Report TECNO MOBILE LIMITED

TECNO MOBILE LIMITED Mobile phone

FCC ID Filing: 2ADYY-CX
Purchase on Amazon: Mobile phone

Trouble Viewing? See the or view the HTML Version or PDF in frame
Page 1 of CX Mobile phone Test Report Measurement Report TECNO MOBILE LIMITED

FCC Report
Application Purpose
Original grant
Applicant Name:
TECNO MOBILE LIMITED
FCC ID
2ADYY-CX
Equipment Type
Mobile phone
Model Name
CX
Report Number
FCC17010035A-4
Standard(S)
FCC Part 15 Subpart B
Date Of Receipt
January 04, 2017
Date Of Issue
February 22, 2017
Test By
Reviewed By
(Daisy Qin)
Sol Qin)
Authorized by
Prepared by
(Michal Ling)
QTC Certification & Testing Co., Ltd.
2nd Floor,Bl Building,Fengyeyuan
Industrial Plant,,
Liuxian 2st. Road, Xin'an Street, Bao'an
District,,Shenzhen,518000
Registration Number: 588523
Page 2 of 53
REPORT REVISE RECORD
Report Version
Revise Time
Issued Date
Valid Version
Notes
V1.0
February 22, 2017
Valid
Original Report
Report No.: FCC17010035A-4
Page 3 of 53
Table of Contents
Page
1. GENERAL INFORMATION
2. TEST DESCRIPTION
2.1 MEASUREMENT UNCERTAINTY
2.2 DESCRIPTION OF TEST MODES
2.3 CONFIGURATION OF SYSTEM UNDER TEST
2.4 DESCRIPTION OF SUPPORT UNITS (CONDUCTED MODE)
3. SUMMARY OF TEST RESULTS
10
4. MEASUREMENT INSTRUMENTS
11
5. EMC EMISSION TEST
12
5.1 CONDUCTED EMISSION MEASUREMENT
5.1.1 POWER LINE CONDUCTED EMISSION LIMITS
5.1.2 TEST PROCEDURE
5.1.3 DEVIATION FROM TEST STANDARD
5.1.4 TEST SETUP
5.1.5 EUT OPERATING CONDITIONS
5.1.6 TEST RESULTS
12
12
13
13
13
13
14
5.2 RADIATED EMISSION MEASUREMENT
5.2.1 RADIATED EMISSION LIMITS
5.2.2 TEST PROCEDURE
5.2.3 DEVIATION FROM TEST STANDARD
5.2.4 TEST SETUP
5.2.5 EUT OPERATING CONDITIONS
5.2.5.1 TEST RESULTS (BETWEEN 30M – 1000 MHZ)
5.2.5.2 TEST RESULTS (1GHZ TO 6GHZ)
24
24
25
25
26
26
27
37
6. EUT TEST PHOTO
40
7. PHOTOGRAPHS OF EUT
44
Report No.: FCC17010035A-4
Page 4 of 53
1. GENERAL INFORMATION
Test Model
CX
Applicant
TECNO MOBILE LIMITED
Address
ROOMS 05-15, 13A/F., SOUTH TOWER, WORLD FINANCE CENTRE,
HARBOUR CITY, 17 CANTON ROAD, TSIM SHA TSUI, KOWLOON, HONG
KONG
Manufacturer
SHENZHEN TECNO TECHNOLOGY CO.,LTD.
Address
1-4th Floor,3rd Building,Pacific Industrial Park,No.2088,Shenyan
Road,Yantian District,Shenzhen,Guangdong,China
Equipment Type Mobile phone
Brand Name
Hardware
V1.6
Software
CX-H501C1-N-161222V32
Battery
information:
Adapter
Information:
Li-Polymer Battery : BL-32AT
Voltage: 3.85V Capacity: 3200mAh/3250mAh(min/typ)
Limited Charge Voltage: 4.4V
Adapter: A88-502000
Input: AC 100~240V 50/60Hz 350mA
Output: DC 5V~2A
Data of receipt
January 04, 2017
Date of test
January 05, 2017 to February 22, 2017
Deviation
None
Condition of
Test Sample
Normal
Report No.: FCC17010035A-4
Page 5 of 53
We hereby certify that:
The above equipment was tested by QTC Certification & Testing Co., Ltd.
2nd Floor,Bl Building,Fengyeyuan Industrial Plant,, Liuxian 2st. Road, Xin'an Street, Bao'an
District,,Shenzhen,518000
Registration Number: 588523
The data evaluation, test procedures, and equipment configurations shown in this report were made in
accordance with the procedures given in ANSI C 63.4:2014. The sample tested as described in this report
is in compliance with the FCC Rules Part15 Subpart B.
The test results of this report relate only to the tested sample identified in this report.
Report No.: FCC17010035A-4
Page 6 of 53
2. TEST DESCRIPTION
2.1 MEASUREMENT UNCERTAINTY
The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
approximately 95 %。
No.
Item
Uncertainty
Conducted Emission Test
±3.2dB
RF power, conducted
±0.16dB
Spurious emissions, conducted
±0.21dB
All emissions, radiated(<1G)
±4.7dB
All emissions, radiated(>1G)
±4.7dB
Temperature
±0.5°C
Humidity
±2%
Report No.: FCC17010035A-4
Page 7 of 53
2.2 DESCRIPTION OF TEST MODES
To investigate the maximum EMI emission characteristics generates from EUT, the test system
was pre-scanning tested base on the consideration of following EUT operation mode or test
configuration mode which possible have effect on EMI emission level. Each of these EUT
operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.
Pretest Mode
Description
Mode 1
Video Recording
Model 2
Video Playing
Mode 3
Exchange data with computer
Mode 4
GPS
Mode 5
FM
For Conducted Emission
Final Test Mode
Test with Keyboard and Mouse
Mode 1
Model 2
Mode 3
Mode 4
Mode 5
Video Recording
Video Playing
Exchange data with computer
GPS
FM
For Radiated Emission
Final Test Mode
Test with Keyboard and Mouse
Mode 1
Model 2
Mode 3
Mode 4
Mode 5
Video Recording
Video Playing
Exchange data with computer
GPS
FM
Report No.: FCC17010035A-4
Page 8 of 53
2.3 CONFIGURATION OF SYSTEM UNDER TEST
Mode 1&2&4&5:
Adapter
100cm USB cable
TF
SIM
Earphone
EUT
(EUT: Mobile phone)
Mode 3:
1m USB cable
NOTEBOOK
1.2m USB
cable
EUT
1.2m USB
cable
Mouse
Keyboard
(EUT: Mobile phone)
I/O Port of EUT
I/O Port Type
Q’TY
Cable
Tested with
Power
1m USB cable, unshielded
Earphone
1m USB cable, unshielded
Report No.: FCC17010035A-4
Page 9 of 53
2.4 DESCRIPTION OF SUPPORT UNITS (CONDUCTED MODE)
The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.
Item
Equipment
Mfr/Brand
Model/Type No.
Series No.
Note
Adapter
A88-502000
Keyboard
HP
SK-2880
435302-AA-
Mouse
DELL
MS111-1
Note:
(1)
(2)
The support equipment was authorized by Declaration of Confirmation.
For detachable type I/O cable should be specified the length in cm in Length column.
Report No.: FCC17010035A-4
Page 10 of 53
3. SUMMARY OF TEST RESULTS
Test procedures according to the technical standards:
FCC Part15 , Subpart B
Standard
Section
Test Item
Judgment
15.107
CONDUCTED EMISSION
PASS
15.109
RADIATED EMISSION
PASS
NOTE:
(1)” N/A” denotes test is not applicable in this test report.
Report No.: FCC17010035A-4
Remark
Page 11 of 53
4. MEASUREMENT INSTRUMENTS
Manufacturer
Type No.
Serial No.
Last
Calibrated
Calibrated
until
ESCI Test Receiver
R&S
ESCI
100005
08/19/2016
08/18/2017
LISN
AFJ
LS16
16010222119
08/19/2016
08/18/2017
LISN(EUT)
Mestec
AN3016
04/10040
08/19/2016
08/18/2017
pre-amplifier
CDSI
PAP-1G18-38
--
08/19/2016
08/18/2017
System Controller
CT
SC100
08/19/2016
08/18/2017
Bi-log Antenna
Chase
CBL6111C
2576
08/19/2016
08/18/2017
Spectrum analyzer
R&S
FSU26
200409
08/19/2016
08/18/2017
Horn Antenna
SCHWARZBECK
9120D
1141
08/19/2016
08/18/2017
Bi-log Antenna
SCHWAREBECK
VULB9163
9163/340
08/19/2016
08/18/2017
Pre Amplifier
H.P.
HP8447E
2945A02715
10/13/2016
10/12/2017
9*6*6 Anechoic
--
--
--
08/21/2016
08/20/2017
Kind of Equipment
Report No.: FCC17010035A-4
Page 12 of 53
5. EMC EMISSION TEST
5.1 CONDUCTED EMISSION MEASUREMENT
5.1.1 POWER LINE CONDUCTED EMISSION Limits
FREQUENCY (MHz)
Class A (dBuV)
(Frequency Range 150KHz-30MHz)
Class B (dBuV)
Standard
Quasi-peak
Average
Quasi-peak
Average
0.15 -0.5
79.00
66.00
66 - 56 *
56 - 46 *
FCC
0.50 -5.0
73.00
60.00
56.00
46.00
FCC
73.00
60.00
60.00
50.00
FCC
5.0 -30.0
Note:
(1) The tighter limit applies at the band edges.
(2) The limit of " * " marked band means the limitation decreases linearly with the
logarithm of the frequency in the range.
The following table is the setting of the receiver
Receiver Parameters
Attenuation
Start Frequency
Stop Frequency
IF Bandwidth
Report No.: FCC17010035A-4
Setting
10 dB
0.15 MHz
30 MHz
9 kHz
Page 13 of 53
5.1.2 TEST PROCEDURE
a. The EUT was placed 0.4 meters from the horizontal ground plane with EUT being connected
to the power mains through a line impedance stabilization network (LISN). All other support
equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
impedance for the measuring instrument.
b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
and forth in the center forming a bundle 30 to 40 cm long.
c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
cable may be terminated, if required, using the correct terminating impedance. The overall
length shall not exceed 1 m.
d. LISN at least 80 cm from nearest part of EUT chassis.
e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
5.1.3 DEVIATION FROM TEST STANDARD
No deviation
5.1.4 TEST SETUP
Vertical Reference
Test Receiver
Ground Plane
40cm
EUT
80cm
LISN
Horizontal Reference
Ground Plane
Note: 1.Support units were connected to second LISN.
2.Both of LISNs (AMN) are 80 cm from EUT and at least 80
from other units and other metal planes
5.1.5 EUT OPERATING CONDITIONS
The EUT was configured for testing in a typical fashion (as a customer would normally use it). The
EUT has been programmed to continuously transmit during test. This operating condition was
tested and used to collect the included data.
Report No.: FCC17010035A-4
Page 14 of 53
5.1.6 TEST RESULTS
EUT
Temperature
Pressure
Test Date
Mobile phone
26 ℃
1010hPa
January 16, 2017
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Phase
Test Mode
CX
54%
Mode 1
Page 15 of 53
EUT
Temperature
Pressure
Test Date
Mobile phone
26 ℃
1010hPa
January 16, 2017
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Phase
Test Mode
CX
54%
Mode 1
Page 16 of 53
EUT
Temperature
Pressure
Test Date
Mobile phone
26 ℃
1010hPa
January 16, 2017
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Phase
Test Mode
CX
54%
Mode 2
Page 17 of 53
EUT
Temperature
Pressure
Test Date
Mobile phone
26 ℃
1010hPa
January 16, 2017
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Phase
Test Mode
CX
54%
Mode 2
Page 18 of 53
EUT
Temperature
Pressure
Test Date
Mobile phone
26 ℃
1010hPa
January 16, 2017
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Phase
Test Mode
CX
54%
Mode 3
Page 19 of 53
EUT
Temperature
Pressure
Test Date
Mobile phone
26 ℃
1010hPa
January 16, 2017
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Phase
Test Mode
CX
54%
Mode 3
Page 20 of 53
EUT
Temperature
Pressure
Test Date
Mobile phone
26 ℃
1010hPa
January 16, 2017
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Phase
Test Mode
CX
54%
Mode 4
Page 21 of 53
EUT
Temperature
Pressure
Test Date
Mobile phone
26 ℃
1010hPa
January 16, 2017
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Phase
Test Mode
CX
54%
Mode 4
Page 22 of 53
EUT
Temperature
Pressure
Test Date
Mobile phone
26 ℃
1010hPa
January 16, 2017
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Phase
Test Mode
CX
54%
Mode 5
Page 23 of 53
EUT
Temperature
Pressure
Test Date
Mobile phone
26 ℃
1010hPa
January 16, 2017
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Phase
Test Mode
CX
54%
Mode 5
Page 24 of 53
5.2 RADIATED EMISSION MEASUREMENT
5.2.1 RADIATED EMISSION LIMITS (Frequency Range 9kHz-1000MHz)
The field strength of radiated emissions from unintentional radiators at a distance of 3 meters shall
not exceed the following values:
Frequencies
Field Strength
Measurement Distance
(MHz)
(micorvolts/meter)
(meters)
0.009~0.490
2400/F(KHz)
300
0.490~1.705
24000/F(KHz)
30
1.705~30.0
30
30
30~88
100
88~216
150
216~960
200
Above 960
500
LIMITS OF RADIATED EMISSION MEASUREMENT (Above 1000MHz)
FREQUENCY (MHz)
Above 1000
Limit (dBuV/m) (at 3M)
PEAK
AVERAGE
74
54
Notes:
(1) The limit for radiated test was performed according to FCC PART 15B.
(2) The tighter limit applies at the band edges.
(3) Emission level (dBuV/m)=20log Emission level (uV/m).
Spectrum Parameter
Setting
Attenuation
Auto
Start Frequency
1000 MHz
Stop Frequency
10th carrier harmonic
RB / VB (emission in restricted
band)
1 MHz / 1 MHz for Peak, 1 MHz / 1Hz for Average
Receiver Parameter
Setting
Attenuation
Auto
Start ~ Stop Frequency
9kHz~150kHz / RB 200Hz for QP
Start ~ Stop Frequency
150kHz~30MHz / RB 9kHz for QP
Start ~ Stop Frequency
30MHz~1000MHz / RB 120kHz for QP
Report No.: FCC17010035A-4
Page 25 of 53
5.2.2 TEST PROCEDURE
a. The measuring distance of at 3 m shall be used for measurements at frequency up to 1GHz.
For frequencies above 1GHz, any suitable measuring distance may be used.
b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter
open area test site. The table was rotated 360 degrees to determine the position of the highest
radiation.
c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test
antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the
antenna are set to make the measurement.
d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector
mode pre-scanning the measurement frequency range. Significant peaks are then marked and
then Quasi Peak detector mode re-measured.
e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
performed.
f. For the actual test configuration, please refer to the related Item –EUT Test Photos.
Note:
Both horizontal and vertical antenna polarities were tested
and performed pretest to three orthogonal axis. The worst case emissions were reported
5.2.3 DEVIATION FROM TEST STANDARD
No deviation
Report No.: FCC17010035A-4
Page 26 of 53
5.2.4 TEST SETUP
A Radiated Emission Test-Up Frequency 30MHz~1GHz
B Radiated Emission Test-Up Frequency Above 1GHz
5.2.5 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 2.4 Unless otherwise a special
operating condition is specified in the follows during the testing.
Report No.: FCC17010035A-4
Page 27 of 53
5.2.5.1 TEST RESULTS (BETWEEN 30M – 1000 MHZ)
EUT
Temperature
Pressure
Test Mode
Mobile phone
20 ℃
1010 hPa
Mode 1
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Polarization :
Test Date
CX
48%
Horizontal
January 16, 2017
Page 28 of 53
EUT
Temperature
Pressure
Test Mode
Mobile phone
20 ℃
1010 hPa
Mode 1
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Polarization :
Test Date
CX
48%
Vertical
January 16, 2017
Page 29 of 53
EUT
Temperature
Pressure
Test Mode
Mobile phone
20 ℃
1010 hPa
Mode 2
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Polarization :
Test Date
CX
48%
Horizontal
January 16, 2017
Page 30 of 53
EUT
Temperature
Pressure
Test Mode
Mobile phone
20 ℃
1010 hPa
Mode 2
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Polarization :
Test Date
CX
48%
Vertical
January 16, 2017
Page 31 of 53
EUT
Temperature
Pressure
Test Mode
Mobile phone
20 ℃
1010 hPa
Mode 3
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Polarization :
Test Date
CX
48%
Horizontal
January 16, 2017
Page 32 of 53
EUT
Temperature
Pressure
Test Mode
Mobile phone
20 ℃
1010 hPa
Mode 3
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Polarization :
Test Date
CX
48%
Vertical
January 16, 2017
Page 33 of 53
EUT
Temperature
Pressure
Test Mode
Mobile phone
20 ℃
1010 hPa
Mode 4
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Polarization :
Test Date
CX
48%
Horizontal
January 16, 2017
Page 34 of 53
EUT
Temperature
Pressure
Test Mode
Mobile phone
20 ℃
1010 hPa
Mode 4
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Polarization :
Test Date
CX
48%
Vertical
January 16, 2017
Page 35 of 53
EUT
Temperature
Pressure
Test Mode
Mobile phone
20 ℃
1010 hPa
Mode 5
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Polarization :
Test Date
CX
48%
Horizontal
January 16, 2017
Page 36 of 53
EUT
Temperature
Pressure
Test Mode
Mobile phone
20 ℃
1010 hPa
Mode 5
Report No.: FCC17010035A-4
Model Name
Relative Humidity
Polarization :
Test Date
CX
48%
Vertical
January 16, 2017
Page 37 of 53
5.2.5.2 TEST RESULTS (1GHZ TO 6GHZ)
EUT
Mobile phone
Temperature
20 ℃
Pressure
Test Date
1010 hPa
January 16, 2017
Freq.
(MHz)
Ant.
Pol.
H/V
1632.45
2829.27
1684.52
2831.6
Model Name
Relative
Humidity
Test Mode
Emission
Level(dBuV)
PK
AV
60.87
58.70
58.11
59.71
40.47
39.42
39.51
40.71
Limit
3m(dBuV/m)
PK
AV
74
74
74
74
54
54
54
54
CX
48%
Mode 1
Over(dB)
PK
AV
-13.13
-15.30
-15.89
-14.29
-13.53
-14.58
-14.49
-13.29
Remark:
All emissions not reported were more than 20dB below the specified limit or in the noise floor.
Factor = Antenna Factor + Cable Loss – Pre-amplifier.
All the x/y/z orientation has been investigated, and only worst case is presented in this report.
EUT
Mobile phone
Temperature
20 ℃
Pressure
Test Date
1010 hPa
January 16, 2017
Freq.
(MHz)
1583.35
2641.52
1628.42
2810.39
Ant.
Pol.
H/V
Model Name
Relative
Humidity
Test Mode
Emission
Level(dBuV)
PK
AV
59.54
59.43
59.63
59.11
41.24
40.30
39.13
40.11
Limit
3m(dBuV/m)
PK
AV
74
74
74
74
54
54
54
54
CX
48%
Mode 2
Over(dB)
PK
AV
-14.46
-14.57
-14.37
-14.89
-12.76
-13.70
-14.87
-13.89
Remark:
All emissions not reported were more than 20dB below the specified limit or in the noise floor.
Factor = Antenna Factor + Cable Loss – Pre-amplifier.
All the x/y/z orientation has been investigated, and only worst case is presented in this report.
Report No.: FCC17010035A-4
Page 38 of 53
EUT
Mobile phone
Temperature
20 ℃
Pressure
Test Date
1010 hPa
January 16, 2017
Freq.
(MHz)
1577.35
2652.38
1699.33
2739.42
Ant.
Pol.
H/V
Model Name
Relative
Humidity
Test Mode
Emission
Level(dBuV)
PK
AV
60.22
59.97
58.91
58.41
41.46
39.04
40.37
39.41
Limit
3m(dBuV/m)
PK
AV
74
74
74
74
54
54
54
54
CX
48%
Mode 3
Over(dB)
PK
AV
-13.78
-14.03
-15.09
-15.59
-12.54
-14.96
-13.63
-14.59
Remark:
All emissions not reported were more than 20dB below the specified limit or in the noise floor.
Factor = Antenna Factor + Cable Loss – Pre-amplifier.
All the x/y/z orientation has been investigated, and only worst case is presented in this report.
EUT
Mobile phone
Temperature
20 ℃
Pressure
Test Date
1010 hPa
January 16, 2017
Freq.
(MHz)
Ant.
Pol.
H/V
1583.35
2641.52
1628.42
2810.39
Model Name
Relative
Humidity
Test Mode
Emission
Level(dBuV)
PK
AV
60.74
58.02
59.36
58.52
40.92
40.95
39.46
39.52
Limit
3m(dBuV/m)
PK
AV
74
74
74
74
54
54
54
54
CX
48%
Mode 4
Over(dB)
PK
AV
-13.26
-15.98
-14.64
-15.48
-13.08
-13.05
-14.54
-14.48
Remark:
All emissions not reported were more than 20dB below the specified limit or in the noise floor.
Factor = Antenna Factor + Cable Loss – Pre-amplifier.
All the x/y/z orientation has been investigated, and only worst case is presented in this report.
Report No.: FCC17010035A-4
Page 39 of 53
EUT
Mobile phone
Temperature
20 ℃
Pressure
Test Date
1010 hPa
January 16, 2017
Freq.
(MHz)
1577.35
2652.38
1699.33
2739.42
Ant.
Pol.
H/V
Model Name
Relative
Humidity
Test Mode
Emission
Level(dBuV)
PK
AV
60.71
58.83
58.06
59.83
40.21
40.46
40.58
40.83
Limit
3m(dBuV/m)
PK
AV
74
74
74
74
54
54
54
54
CX
48%
Mode 5
Over(dB)
PK
AV
-13.29
-15.17
-15.94
-14.17
-13.79
-13.54
-13.42
-13.17
Remark:
All emissions not reported were more than 20dB below the specified limit or in the noise floor.
Factor = Antenna Factor + Cable Loss – Pre-amplifier.
All the x/y/z orientation has been investigated, and only worst case is presented in this report.
Report No.: FCC17010035A-4
Page 40 of 53
6. EUT TEST PHOTO
CONDUCTED EMISSION TEST
CONDUCTED EMISSION TEST
Report No.: FCC17010035A-4
Page 41 of 53
RADIATED EMISSION TEST
RADIATED EMISSION TEST
Report No.: FCC17010035A-4
Page 42 of 53
RADIATED EMISSION TEST
RADIATED EMISSION TEST
Report No.: FCC17010035A-4
Page 43 of 53
RADIATED EMISSION TEST
RADIATED EMISSION TEST
Report No.: FCC17010035A-4
Page 44 of 53
7. PHOTOGRAPHS OF EUT
Appearance photograph of EUT
Appearance photograph of EUT
Report No.: FCC17010035A-4
Page 45 of 53
Appearance photograph of EUT
Appearance photograph of EUT
Report No.: FCC17010035A-4
Page 46 of 53
Appearance photograph of EUT
Appearance photograph of EUT
Report No.: FCC17010035A-4
Page 47 of 53
Appearance photograph of EUT
Internal photograph of EUT
Report No.: FCC17010035A-4
Page 48 of 53
Internal photograph of EUT
BT/WiFi Antenna
GSM/WCDMA/LT
E Antenna
Internal photograph of EUT
Report No.: FCC17010035A-4
Page 49 of 53
Internal photograph of EUT
Internal photograph of EUT
Report No.: FCC17010035A-4
Page 50 of 53
Internal photograph of EUT
Internal photograph of EUT
Report No.: FCC17010035A-4
Page 51 of 53
Internal photograph of EUT
Internal photograph of EUT
Report No.: FCC17010035A-4
Page 52 of 53
Internal photograph of EUT
Internal photograph of EUT
Report No.: FCC17010035A-4
Page 53 of 53
Internal photograph of EUT
Internal photograph of EUT
---END OF REPORT---
Report No.: FCC17010035A-4
Download: CX Mobile phone Test Report Measurement Report TECNO MOBILE LIMITED
Mirror Download [FCC.gov]CX Mobile phone Test Report Measurement Report TECNO MOBILE LIMITED
Document ID3323639
Application IDe/SJ+SMuj+f8BOWkQLu0dQ==
Document Descriptiontest report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize329.69kB (4121169 bits)
Date Submitted2017-03-20 00:00:00
Date Available2017-03-20 00:00:00
Creation Date2017-12-26 19:43:56
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-12-26 19:43:56
Document TitleMeasurement Report
Document CreatorMicrosoft® Office Word 2007
Document Author: Kent

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 1
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:2b05a2ab-9eb4-11f2-0000-02c7314339d4
Producer                        : GPL Ghostscript 9.18
Modify Date                     : 2017:07:12 00:18:24Z
Create Date                     : 2017:07:12 00:18:24Z
Creator Tool                    : UnknownApplication
Document ID                     : uuid:2b05a2ab-9eb4-11f2-0000-02c7314339d4
Format                          : application/pdf
Title                           : Untitled
EXIF Metadata provided by EXIF.tools

Facebook Twitter Google+ RSS © FCCID.io 2018