FCC ID 2ADYY-KE5K

Mobile Phone

by TECNO MOBILE LIMITED

Grantee Code: 2ADYY   Product Code: KE5K
Latest application date: 2020-09-16

FCC ID Device Details

FCC ID2ADYY-KE5K
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ADYY
Product CodeKE5K
Applicant BusinessTECNO MOBILE LIMITED
Related Domains transsion.com
Equipment ClassMobile Phone
Test FirmWaltek Testing Group (Shenzhen) Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2020-09-16
2402-2480 MHzOriginal Equipment2020-09-16
824.2-848.8 MHzOriginal Equipment2020-09-16

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2021-03-15PDF 755 KB
Internal photosInternal Photos2021-03-15PDF 4.9 MB
External photosExternal Photos2021-03-15PDF 538.2 KB
Label info.ID Label/Location Info2020-09-16PDF 173.8 KB
Test setup photo SARTest Setup Photos2021-03-15PDF 2.3 MB
Test setup photos RFTest Setup Photos2021-03-15PDF 333.1 KB
Test setup photos RFTest Setup Photos2021-03-15PDF 380.8 KB
Test setup photos SARTest Setup Photos2021-03-15PDF 2.3 MB
Appendix for Band 2_01Test Report2020-09-16PDF 5.6 MB
Appendix for Band 2_02Test Report2020-09-16PDF 5.6 MB
Appendix for Band 2_03Test Report2020-09-16PDF 5.7 MB
Appendix for Band 2_4Test Report2020-09-16PDF 5.6 MB
Appendix for Band 2_5Test Report2020-09-16PDF 5.6 MB
Appendix for Band 2_6Test Report2020-09-16PDF 4 MB
Appendix for Band 38_1Test Report2020-09-16PDF 5.6 MB
Appendix for Band 38_2Test Report2020-09-16PDF 5.5 MB
Appendix for Band 38_3Test Report2020-09-16PDF 5.6 MB
Appendix for Band 38_4Test Report2020-09-16PDF 5.4 MB
Appendix for Band 41_1Test Report2020-09-16PDF 5.6 MB
Appendix for Band 41_2Test Report2020-09-16PDF 5.6 MB
Appendix for Band 41_3Test Report2020-09-16PDF 5.6 MB
Appendix for Band 41_4Test Report2020-09-16PDF 5.4 MB
Appendix for Band 4_1Test Report2020-09-16PDF 5.5 MB
Appendix for Band 4_2Test Report2020-09-16PDF 5.6 MB
Appendix for Band 4_3Test Report2020-09-16PDF 5.7 MB
Appendix for Band 4_4Test Report2020-09-16PDF 5.6 MB
Appendix for Band 4_5Test Report2020-09-16PDF 5.6 MB
Appendix for Band 4_6Test Report2020-09-16PDF 4.2 MB
Appendix for Band 5_1Test Report2020-09-16PDF 5.6 MB
Appendix for Band 5_2Test Report2020-09-16PDF 4.9 MB
Appendix for Band 5_3Test Report2020-09-16PDF 5.5 MB
Appendix for Band 5_4Test Report2020-09-16PDF 5.3 MB
Appendix for Band 7_1Test Report2020-09-16PDF 5.6 MB
Appendix for Band 7_2Test Report2020-09-16PDF 5.4 MB
Appendix for Band 7_3Test Report2020-09-16PDF 5.6 MB
Appendix for Band 7_4Test Report2020-09-16PDF 5.4 MB
Test report 2G3GTest Report2020-09-16PDF 3.2 MB
Test report 4GTest Report2020-09-16PDF 1.5 MB
Test report BTTest Report2020-09-16PDF 1.4 MB
Test report RFTest Report2020-09-16PDF 1.7 MB
Test report SAR 1RF Exposure Info2020-09-16PDF 2.8 MB
Test report SAR 2RF Exposure Info2020-09-16PDF 3 MB
Test report Wi-FiTest Report2020-09-16PDF 2.1 MB
SDOC letterAttestation Statements2020-09-16PDF 175.5 KB
Confidentiality request letterCover Letter(s)2020-09-16PDF 215.4 KB
Label justification letterCover Letter(s)2020-09-16PDF 128.7 KB
POACover Letter(s)2020-09-16PDF 79.5 KB
Calibration certificateRF Exposure Info2020-09-16PDF 2.5 MB
Block diagram Metadata onlyBlock DiagramPDF 190 KB
Schematic diagram Metadata onlySchematicsPDF 4.2 MB
Operation description Metadata onlyOperational DescriptionPDF 658 KB
Part list Metadata onlyParts List/Tune Up InfoPDF 210.2 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 79.2 KB

Application Information

Application IDfl5cNShJYTBWNMf0jgrj3g==
Final Action Date2020-09-16
Application PurposeOriginal Equipment
Applicant FRN0024206328
ModelKE5K
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionMobile Phone
Responsible PartyYiting Luo, yiting.luo@transsion.com , 86-755-61803856
Test FirmJandy So, Waltek Testing Group (Shenzhen) Co., Ltd., jandyso@semtest.com.cn , 86 755 33663308
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date03/15/2021
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is conducted.

Applications

Application IDDatePurpose
fl5cNShJYTBWNMf0jgrj3g==2020-09-16Original Equipment
cYbSgMcrRO9EvQRZUAmA/A==2020-09-16Original Equipment
aTzCxghBNF4vg31KVzSldw==2020-09-16Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz0.26980.0864ppm257KG7W22H
824.7-848.3 MHz0.11530.0061ppm1M08G7D22H
824.7-848.3 MHz0.11560.0061ppm1M08W7D22H
826.4-846.6 MHz0.11720.0864ppm4M19F9W22H
829-844 MHz0.10640.0058ppm8M95G7D22H
829-844 MHz0.10690.0058ppm8M95W7D22H
1711.5-1753.5 MHz0.11990.0028ppm2M68W7D27
1712.4-1752.6 MHz0.10940.0466ppm4M20F9W27
1715-1750 MHz0.11190.0028ppm8M94G7D27
1720-1745 MHz0.10330.0029ppm17M9G7D27
1720-1745 MHz0.10990.0029ppm17M9W7D27
1850.2-1909.8 MHz0.27290.0352ppm249KG7W24E
1852.4-1907.6 MHz0.11040.0299ppm4M19F9W24E
1857.5-1902.5 MHz0.11190.0027ppm13M4W7D24E
1860-1900 MHz0.11120.0026ppm17M9W7D24E
1860-1900 MHz0.11190.0026ppm17M9G7D24E
2402-2480 MHz0.000315C
2402-2480 MHz0.004700015C
2412-2462 MHz0.040515C
2498.5-2687.5 MHz0.11890.002ppm4M47W7D27
2502.5-2567.5 MHz0.12530.002ppm4M48G7D27
2503.5-2682.5 MHz0.12450.002ppm13M4G7D27
2506-2680 MHz0.12450.0043ppm17M9G7D27
2506-2680 MHz0.11190.0043ppm17M9W7D27
2510-2560 MHz0.10860.002ppm17M9G7D27
2510-2560 MHz0.11190.002ppm17M9W7D27
2577.5-2612.5 MHz0.11530.0019ppm13M4W7D27
2580-2610 MHz0.12470.0019ppm17M9G7D27
2580-2610 MHz0.11190.0019ppm17M9W7D27

Grants

TCB Grant - Application fl5cNShJYTBWNMf0jgrj3g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 09/16/2020

Application Dated: 09/16/2020
TECNO MOBILE LIMITED
FLAT 39 8/F BLOCK D WAH LOK INDUSTRIAL
CENTRE 31-35 SHAN MEI STREET FOTAN NT
NT,
Hong Kong
 
Attention: Yiting Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADYY-KE5K
Name of Grantee:  TECNO MOBILE LIMITED
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0047  

Output Power listed is conducted.

EAS Grant - Application fl5cNShJYTBWNMf0jgrj3g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

TECNO MOBILE LIMITED
FLAT 39 8/F BLOCK D WAH LOK INDUSTRIAL CENTRE 31-35 SHAN MEI STREET FOTAN NT
NT,
Hong Kong
  Date of Grant: 09/16/2020

Application Dated: 09/16/2020
 
Attention: Yiting Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADYY-KE5K
Name of Grantee:  TECNO MOBILE LIMITED
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Mobile Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0047  

Output Power listed is conducted.



TCB Grant - Application cYbSgMcrRO9EvQRZUAmA/A==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 09/16/2020

Application Dated: 09/16/2020
TECNO MOBILE LIMITED
FLAT 39 8/F BLOCK D WAH LOK INDUSTRIAL
CENTRE 31-35 SHAN MEI STREET FOTAN NT
NT,
Hong Kong
 
Attention: Yiting Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADYY-KE5K
Name of Grantee:  TECNO MOBILE LIMITED
Equipment Class: Digital Transmission System
Notes: Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0003  
15C 2412.0  -  2462.0 0.0405  

Output Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to belt-clips and holsters that have no metallic components in the assembly and cause the device to operate with the minimum separation distance of 1.0 cm, as described in this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission exposure conditions are 0.19 W/kg, 0.31 W/kg, 0.31 W/kg and 1.01 W/kg, respectively. This device supports 20 and 40 MHz bandwidth modes.

EAS Grant - Application cYbSgMcrRO9EvQRZUAmA/A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

TECNO MOBILE LIMITED
FLAT 39 8/F BLOCK D WAH LOK INDUSTRIAL CENTRE 31-35 SHAN MEI STREET FOTAN NT
NT,
Hong Kong
  Date of Grant: 09/16/2020

Application Dated: 09/16/2020
 
Attention: Yiting Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADYY-KE5K
Name of Grantee:  TECNO MOBILE LIMITED
Equipment Class: Digital Transmission System
Notes: Mobile Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0003  
15C 2412.0  -  2462.0 0.0405  

Output Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to belt-clips and holsters that have no metallic components in the assembly and cause the device to operate with the minimum separation distance of 1.0 cm, as described in this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission exposure conditions are 0.19 W/kg, 0.31 W/kg, 0.31 W/kg and 1.01 W/kg, respectively. This device supports 20 and 40 MHz bandwidth modes.



TCB Grant - Application aTzCxghBNF4vg31KVzSldw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 09/16/2020

Application Dated: 09/16/2020
TECNO MOBILE LIMITED
FLAT 39 8/F BLOCK D WAH LOK INDUSTRIAL
CENTRE 31-35 SHAN MEI STREET FOTAN NT
NT,
Hong Kong
 
Attention: Yiting Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADYY-KE5K
Name of Grantee:  TECNO MOBILE LIMITED
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.1722 0.0864  PM 255KGXW
24E 1850.2  -  1909.8 0.7482 0.0352  PM 253KGXW
22H 824.2  -  848.8 0.2698 0.0864  PM 257KG7W
24E 1850.2  -  1909.8 0.2729 0.0352  PM 249KG7W
22H 826.4  -  846.6 0.1172 0.0864  PM 4M19F9W
27 1712.4  -  1752.6 0.1094 0.0466  PM 4M20F9W
24E 1852.4  -  1907.6 0.1104 0.0299  PM 4M19F9W
24E 1860.0  -  1900.0 0.1119 0.0026  PM 17M9G7D
24E 1857.5  -  1902.5 0.1119 0.0027  PM 13M4W7D
24E 1860.0  -  1900.0 0.1112 0.0026  PM 17M9W7D
27 1715.0  -  1750.0 0.1119 0.0028  PM 8M94G7D
27 1720.0  -  1745.0 0.1033 0.0029  PM 17M9G7D
27 1711.5  -  1753.5 0.1199 0.0028  PM 2M68W7D
27 1720.0  -  1745.0 0.1099 0.0029  PM 17M9W7D
22H 824.7  -  848.3 0.1153 0.0061  PM 1M08G7D
22H 829.0  -  844.0 0.1064 0.0058  PM 8M95G7D
22H 824.7  -  848.3 0.1156 0.0061  PM 1M08W7D
22H 829.0  -  844.0 0.1069 0.0058  PM 8M95W7D
27 2502.5  -  2567.5 0.1253 0.002  PM 4M48G7D
27 2510.0  -  2560.0 0.1086 0.002  PM 17M9G7D
27 2510.0  -  2560.0 0.1119 0.002  PM 17M9W7D
27 2580.0  -  2610.0 0.1247 0.0019  PM 17M9G7D
27 2577.5  -  2612.5 0.1153 0.0019  PM 13M4W7D
27 2580.0  -  2610.0 0.1119 0.0019  PM 17M9W7D
27 2503.5  -  2682.5 0.1245 0.002  PM 13M4G7D
27 2506.0  -  2680.0 0.1245 0.0043  PM 17M9G7D
27 2498.5  -  2687.5 0.1189 0.002  PM 4M47W7D
27 2506.0  -  2680.0 0.1119 0.0043  PM 17M9W7D

Output Power is EIRP and ERP for above and below 1 GHz, respectively. SAR compliance for body-worn operating configurations is limited to belt-clips and holsters that have no metallic components in the assembly and cause the device to operate with the minimum separation distance of 1.0 cm, as described in this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission exposure conditions are 0.76 W/kg, 0.70 W/kg, 0.74 W/kg and 1.01 W/kg, respectively. This device supports LTE of 1.4, 3, 5, 10, 15 and 20 MHz bandwidth modes for FDD LTE Bands 2 and 4; LTE of 5, 10, 15 and 20 MHz bandwidth modes for FDD LTE Band 7; LTE of 1.4, 3, 5 and 10 MHz bandwidth modes for FDD LTE Band 5; and LTE of 5, 10, 15 and 20 MHz bandwidth modes for TDD LTE Band 38 and 41. This device contains functions that are not operational in U.S. Territories; this filing is applicable only for U.S. operations.

EAS Grant - Application aTzCxghBNF4vg31KVzSldw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

TECNO MOBILE LIMITED
FLAT 39 8/F BLOCK D WAH LOK INDUSTRIAL CENTRE 31-35 SHAN MEI STREET FOTAN NT
NT,
Hong Kong
  Date of Grant: 09/16/2020

Application Dated: 09/16/2020
 
Attention: Yiting Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ADYY-KE5K
Name of Grantee:  TECNO MOBILE LIMITED
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mobile Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.1722 0.0864  PM 255KGXW
24E 1850.2  -  1909.8 0.7482 0.0352  PM 253KGXW
22H 824.2  -  848.8 0.2698 0.0864  PM 257KG7W
24E 1850.2  -  1909.8 0.2729 0.0352  PM 249KG7W
22H 826.4  -  846.6 0.1172 0.0864  PM 4M19F9W
27 1712.4  -  1752.6 0.1094 0.0466  PM 4M20F9W
24E 1852.4  -  1907.6 0.1104 0.0299  PM 4M19F9W
24E 1860.0  -  1900.0 0.1119 0.0026  PM 17M9G7D
24E 1857.5  -  1902.5 0.1119 0.0027  PM 13M4W7D
24E 1860.0  -  1900.0 0.1112 0.0026  PM 17M9W7D
27 1715.0  -  1750.0 0.1119 0.0028  PM 8M94G7D
27 1720.0  -  1745.0 0.1033 0.0029  PM 17M9G7D
27 1711.5  -  1753.5 0.1199 0.0028  PM 2M68W7D
27 1720.0  -  1745.0 0.1099 0.0029  PM 17M9W7D
22H 824.7  -  848.3 0.1153 0.0061  PM 1M08G7D
22H 829.0  -  844.0 0.1064 0.0058  PM 8M95G7D
22H 824.7  -  848.3 0.1156 0.0061  PM 1M08W7D
22H 829.0  -  844.0 0.1069 0.0058  PM 8M95W7D
27 2502.5  -  2567.5 0.1253 0.002  PM 4M48G7D
27 2510.0  -  2560.0 0.1086 0.002  PM 17M9G7D
27 2510.0  -  2560.0 0.1119 0.002  PM 17M9W7D
27 2580.0  -  2610.0 0.1247 0.0019  PM 17M9G7D
27 2577.5  -  2612.5 0.1153 0.0019  PM 13M4W7D
27 2580.0  -  2610.0 0.1119 0.0019  PM 17M9W7D
27 2503.5  -  2682.5 0.1245 0.002  PM 13M4G7D
27 2506.0  -  2680.0 0.1245 0.0043  PM 17M9G7D
27 2498.5  -  2687.5 0.1189 0.002  PM 4M47W7D
27 2506.0  -  2680.0 0.1119 0.0043  PM 17M9W7D

Output Power is EIRP and ERP for above and below 1 GHz, respectively. SAR compliance for body-worn operating configurations is limited to belt-clips and holsters that have no metallic components in the assembly and cause the device to operate with the minimum separation distance of 1.0 cm, as described in this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission exposure conditions are 0.76 W/kg, 0.70 W/kg, 0.74 W/kg and 1.01 W/kg, respectively. This device supports LTE of 1.4, 3, 5, 10, 15 and 20 MHz bandwidth modes for FDD LTE Bands 2 and 4; LTE of 5, 10, 15 and 20 MHz bandwidth modes for FDD LTE Band 7; LTE of 1.4, 3, 5 and 10 MHz bandwidth modes for FDD LTE Band 5; and LTE of 5, 10, 15 and 20 MHz bandwidth modes for TDD LTE Band 38 and 41. This device contains functions that are not operational in U.S. Territories; this filing is applicable only for U.S. operations.



Mail To: