5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion

Loop Labs, Inc. dba Notion Bridge

FCC ID Filing: 2AE5C-5280-B2
Purchase on Amazon: Bridge

Download: 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion
Document DescriptionMPE Report
Document TypeRF Exposure Info
Document TitleFCC IC RF EXPOSURE REPORT

Document

Trouble Loading? Try 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion Download this document or view the HTML Version or PDF in frame.
Page 1 of 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion
Page 2 of 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion
Page 3 of 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion
Page 4 of 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion
Page 5 of 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion
Page 6 of 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion
Page 7 of 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion
Page 8 of 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion
Page 9 of 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion
Page 10 of 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion
Page 11 of 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion

FCC Part 1 Subpart I
FCC Part 2 Subpart J
INDUSTRY CANADA RSS 102 ISSUE 5
RF EXPOSURE REPORT
FOR
BRIDGE
MODEL NUMBERS: 0008
REPORT NUMBER: 11908391-E4V1
ISSUE DATE: August 31, 2017
Prepared for
LOOP LABS, INC.
1530 BLAKE ST.
DENVER, CO
80202
Prepared by
UL VERIFICATION SERVICES INC.
47173 BENICIA STREET
FREMONT, CA 94538, U.S.A.
TEL: (510) 771-1000
FAX: (510) 661-0888
REPORT NO: 11908391-E4V1
FCC ID: 2AE5C-5280-B2
DATE: August 31, 2017
IC: 20391-5280B2
Revision History
Rev.
--
Issue
Date
Revisions
Revised By
8/31/2017
Initial Issue
---
Page 2 of 11
UL VERIFICATION SERVICES INC.
FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA
TEL: (510) 771-1000
FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.
REPORT NO: 11908391-E4V1
FCC ID: 2AE5C-5280-B2
DATE: August 31, 2017
IC: 20391-5280B2
TABLE OF CONTENTS
1.
ATTESTATION OF TEST RESULTS ................................................................................. 4
2.
TEST METHODOLOGY ..................................................................................................... 5
3.
REFERENCES ................................................................................................................... 5
4.
FACILITIES AND ACCREDITATION ................................................................................. 5
5.
MAXIMUM PERMISSIBLE RF EXPOSURE ....................................................................... 6
6.
5.1.
FCC RULES ................................................................................................................ 6
5.2.
IC RULES .................................................................................................................... 7
5.3.
EQUATIONS................................................................................................................ 8
5.4.
IC EXEMPTION ..........................................................................................................10
RF EXPOSURE RESULTS ................................................................................................11
Page 3 of 11
UL VERIFICATION SERVICES INC.
FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA
TEL: (510) 771-1000
FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.
REPORT NO: 11908391-E4V1
FCC ID: 2AE5C-5280-B2
DATE: August 31, 2017
IC: 20391-5280B2
1. ATTESTATION OF TEST RESULTS
COMPANY NAME:
Loop Labs, Inc.
1530 Blake St.
Denver, CO
80202
EUT DESCRIPTION:
BRIDGE
MODEL:
0008
APPLICABLE STANDARDS
STANDARD
TEST RESULTS
FCC PART 1 SUBPART I & PART 2 SUBPART J
Pass
INDUSTRY CANADA RSS 102 ISSUE 5
Pass
UL Verification Services Inc. calculated the RF Exposure of the above equipment in
accordance with the requirements set forth in the above standards, using test results reported in
the test report documents referenced below and/or documentation furnished by the applicant.
All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc.
based on interpretations of these calculations. The results show that the equipment is capable
of demonstrating compliance with the requirements as documented in this report.
Note: The results documented in this report apply only to the tested sample, under the
conditions and modes of operation as described herein. This document may not be altered or
revised in any way unless done so by UL Verification Services Inc. and all revisions are duly
noted in the revisions section. Any alteration of this document not carried out by UL Verification
Services Inc. will constitute fraud and shall nullify the document. This report must not be used
by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any
agency of the Federal Government, or any agency of the U.S. government.
Approved & Released For
UL Verification Services Inc. By:
Francisco de Anda
CONSUMER TECHNOLOGY DIVISION
Program Manager
UL Verification Services Inc.
Page 4 of 11
UL VERIFICATION SERVICES INC.
FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA
TEL: (510) 771-1000
FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.
REPORT NO: 11908391-E4V1
FCC ID: 2AE5C-5280-B2
DATE: August 31, 2017
IC: 20391-5280B2
2. TEST METHODOLOGY
All calculations were made in accordance with FCC OET Bulletin 65 Edition 97-01 and IC Safety
Code 6.
3. REFERENCES
All measurements were made as documented in test report UL Verification Services Inc.
Document 11908391-E1V1 FCCIC 802.15.4 Report for operation in the 2.4 GHz band for
802.15.4 mode. For wifi mode, data from document report number SA150528E05, MPE report,
for certified module, FCC ID: TLZ-CU300 was used.
Duty cycle data is excerpted from the applicable test reports.
Output power is excerpted from the applicable test reports and Antenna gain data is excerpted
from product documentation provided by the applicant.
4. FACILITIES AND ACCREDITATION
The test sites and measurement facilities used to collect data are located at 47173 Benicia
Street, Fremont, California, USA.
UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0.
Page 5 of 11
UL VERIFICATION SERVICES INC.
FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA
TEL: (510) 771-1000
FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.
REPORT NO: 11908391-E4V1
FCC ID: 2AE5C-5280-B2
DATE: August 31, 2017
IC: 20391-5280B2
5. MAXIMUM PERMISSIBLE RF EXPOSURE
5.1.
FCC RULES
§1.1310 The criteria listed in Table 1 shall be used to evaluate the environmental impact of
human exposure to radio-frequency (RF) radiation as specified in §1.1307(b), except in the case
of portable devices which shall be evaluated according to the provisions of §2.1093 of this
chapter.
TABLE 1—LIMITS FOR M AXIMUM PERMISSIBLE EXPOSURE (MPE)
Frequency range Electric field strength Magnetic field strength Power density Averaging time
(MHz)
(V/m)
(A/m)
(mW/cm )
(minutes)
(A) Limits for Occupational/Controlled Exposure
0.3-3.0
614
1.63
*100
3.0-30
1842/f
4.89/f
30-300
61.4
0.163
1.0
f/300
1.63
*100
30
30
0.2
30
f/1500
30
1.0
30
300-1,500
*900/f
1,500-100,000
(B) Limits for General Population/Uncontrolled Exposure
0.3-1.34
614
1.34-30
824/f
2.19/f
30-300
27.5
0.073
300-1,500
1,500-100,000
*180/f
f = frequency in MHz
* = Plane-wave equivalent power density
Notes:
(1) Occupational/controlled exposure limits apply in situations in which persons are exposed
as a consequence of their employment provided those persons are fully aware of the
potential for exposure and can exercise control over their exposure. Limits for
occupational/controlled exposure also apply in situations when a person is transient
through a location where occupational/controlled limits apply provided he or she is made
aware of the potential for exposure.
(2) General population/uncontrolled exposure limits apply in situations in which the general
public may be exposed, or in which persons who are exposed as a consequence of their
employment may not be fully aware of the potential for exposure or cannot exercise
control over their exposure
Page 6 of 11
UL VERIFICATION SERVICES INC.
FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA
TEL: (510) 771-1000
FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.
REPORT NO: 11908391-E4V1
FCC ID: 2AE5C-5280-B2
5.2.
DATE: August 31, 2017
IC: 20391-5280B2
IC RULES
IC Safety Code 6 (2015), Section 2.2.2: To ensure compliance with the basic restrictions outlined in
Section 2.1, at frequencies between 10 MHz and 300 GHz, the reference levels for electric- and magnetic-field
strength and power density must be complied with.
TABLE 5: Reference Levels for Electric Field Strength, Magnetic Field Strength and Power
Density in Uncontrolled Environments
TABLE 6: Reference Levels for Electric Field Strength, Magnetic Field Strength and Power
Density in Controlled Environments
Page 7 of 11
UL VERIFICATION SERVICES INC.
FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA
TEL: (510) 771-1000
FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.
REPORT NO: 11908391-E4V1
FCC ID: 2AE5C-5280-B2
5.3.
DATE: August 31, 2017
IC: 20391-5280B2
EQUATIONS
POWER DENSITY
Power density is given by:
S = EIRP / (4 * Pi * D^2)
Where
S = Power density in mW/cm^2
EIRP = Equivalent Isotropic Radiated Power in mW
D = Separation distance in cm
Power density in units of mW/cm^2 is converted to units of W/m^2 by multiplying by 10.
DISTANCE
Distance is given by:
D = SQRT (EIRP / (4 * Pi * S))
Where
D = Separation distance in cm
EIRP = Equivalent Isotropic Radiated Power in mW
S = Power density in mW/cm^2
SOURCE-BASED DUTY CYCLE
Where applicable (for example, multi-slot cell phone applications) a duty cycle factor may be
applied.
Source-based time-averaged EIRP = (DC / 100) * EIRP
Where
DC = Duty Cycle in %, as applicable
EIRP = Equivalent Isotropic Radiated Power in W
Page 8 of 11
UL VERIFICATION SERVICES INC.
FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA
TEL: (510) 771-1000
FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.
REPORT NO: 11908391-E4V1
FCC ID: 2AE5C-5280-B2
DATE: August 31, 2017
IC: 20391-5280B2
MIMO AND COLOCATED TRANSMITTERS (IDENTICAL LIMIT FOR ALL TRANSMITTERS)
For multiple chain devices, and colocated transmitters operating simultaneously in frequency
bands where the limit is identical, the total power density is calculated using the total EIRP
obtained by summing the EIRP (in linear units) of each transmitter.
Total EIRP = (EIRP1) + (EIRP2) + ... + (EIRPn)
where
EIRPx = Source-based time-averaged EIRP of chain x or transmitter x
The total EIRP is then used to calculate the Power Density or the Distance as applicable.
MIMO AND COLOCATED TRANSMITTERS
For multiple colocated transmitters operating simultaneously in frequency bands where different
limits apply:
The Power Density at the specified separation distance is calculated for each transmitter chain
or transmitter.
The fraction of the exposure limit is calculated for each chain or transmitter as
(Power Density of chain or transmitter) / (Limit applicable to that chain or transmitter).
The fractions are summed.
Compliance is established if the sum of the fractions is less than or equal to one.
Page 9 of 11
UL VERIFICATION SERVICES INC.
FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA
TEL: (510) 771-1000
FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.
REPORT NO: 11908391-E4V1
FCC ID: 2AE5C-5280-B2
5.4.
DATE: August 31, 2017
IC: 20391-5280B2
IC EXEMPTION
INDUSTRY CANADA EXEMPTION
RSS-102 Clause 2.5.2 RF exposure evaluation is required if the separation distance between
the user and the device’s radiating element is greater than 20 cm, except when the device
operates as follows:
• at or above 300 MHz and below 6 GHz and the source-based, time-averaged maximum e.i.r.p.
of the device is equal to or less than 1.31 x 10-2 ƒ0.6834 W (adjusted for tune-up tolerance), where
ƒ is in MHz;
Page 10 of 11
UL VERIFICATION SERVICES INC.
FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA
TEL: (510) 771-1000
FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.
REPORT NO: 11908391-E4V1
FCC ID: 2AE5C-5280-B2
DATE: August 31, 2017
IC: 20391-5280B2
6. RF EXPOSURE RESULTS
In the table(s) below, Power and Gain are entered in units of dBm and dBi respectively and
conversions to linear forms are used for the calculations.
(Single chain transmitters, no colocation, MPE distance > 20 cm)
Single Chain and non-colocated transmitters
Band
Mode
Separatio Output Antenna Duty EIRP FCC Power
IC
Power
Distance
AVG
Gain
Cycle
Density
Density
Power
(cm)
(dBm)
(dBi)
(%)
(mW) (mW/cm^2) (W/m^2)
2.4 GHz
802.15.4
20
5.11
3.70
100.0
7.6
0.002
0.02
*2.4 GHz
802.11
20
23.11
5.12
100.0
665.3
0.132
1.32
The device operates above 300 MHz and below 6 GHz with a maximum EIRP less than or
equal to 2.7 Watts in 2.4GHz band as a mobile device with a minimum separation distance of 20
cm, therefore it is exempt from routine RF Exposure Evaluation under RSS-102.
Notes:
1) For MPE the new KDB 447498 requires the calculations to use the maximum rated
power; that power should be declared by the manufacturer, and should not be lower than
the measured power. If the power has a tolerance then we also need to check that the
measured power is within the tolerance.
2) A tolerance value of +0.7 dB was included in the output power values above for 2.4GHz
802.15.4 mode to cover the output power tolerance under extreme conditions in the real
filed as declared by the client. For Wifi mode the data was obtained from the certified
module MPE report.
3) The manufacturer configures output power so that the maximum power, after accounting
for manufacturing tolerances, will never exceed the maximum power level measured.
4) The output power in the tables above is the maximum power per chain among various
channels and various modes within the specific band.
5) The antenna gain in the tables above is the maximum antenna gain among various
channels within the specified band.
END OF REPORT
Page 11 of 11
UL VERIFICATION SERVICES INC.
FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA
TEL: (510) 771-1000
FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.
Download: 5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion
Mirror Download [FCC.gov]5280-B2 Bridge RF Exposure Info FCC IC RF EXPOSURE REPORT Loop Labs, Inc. dba Notion
Document ID3548892
Application IDVYxXxvAMoMVL4jv4wUJV0Q==
Document DescriptionMPE Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize26.13kB (326609 bits)
Date Submitted2017-09-07 00:00:00
Date Available2017-09-07 00:00:00
Creation Date2017-08-31 09:57:52
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2017-08-31 09:58:12
Document TitleFCC IC RF EXPOSURE REPORT
Document CreatorMicrosoft® Word 2010
Document Author: Mike Heckrotte

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Mike Heckrotte
Create Date                     : 2017:08:31 09:57:52-07:00
Modify Date                     : 2017:08:31 09:58:12-07:00
Language                        : en-US
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Creator                         : Mike Heckrotte
Title                           : FCC IC RF EXPOSURE REPORT
Creator Tool                    : Microsoft® Word 2010
Metadata Date                   : 2017:08:31 09:58:12-07:00
Producer                        : Microsoft® Word 2010
Document ID                     : uuid:9911d135-e5ef-475e-bd1c-0bb78bc92e1d
Instance ID                     : uuid:100f76cc-2ce2-4606-86eb-7cd4e7c9d568
Page Count                      : 11