FCC ID 2AEHF-VOLTNX5
3G Mobile Phone
by NOBUX, LLC
Grantee Code: 2AEHF Product Code: VOLTNX5
Latest application date: 2016-11-30
Device Images

























FCC ID Device Details
| FCC ID | 2AEHF-VOLTNX5 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AEHF |
| Product Code | VOLTNX5 |
| Applicant Business | NOBUX, LLC 🇺🇸 |
| Related Domains | |
| Equipment Class | 3G Mobile Phone |
| Test Firm | Waltek Services(Shenzhen) Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2016-11-30 |
| 2402-2480 MHz | Original Equipment | 2016-11-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2016-11-30 | PDF 306.5 KB |
| User manual | Users Manual | 2016-11-30 | PDF 306.5 KB |
| Internal Photos | Internal Photos | 2016-11-30 | PDF 892.8 KB |
| External Photos | External Photos | 2016-11-30 | PDF 760.1 KB |
| Label and Label Location | ID Label/Location Info | 2016-11-30 | PDF 101.5 KB |
| Test set-up photos | Test Setup Photos | 2016-11-30 | PDF 300.4 KB |
| SAR Test Report | RF Exposure Info | 2016-11-30 | PDF 3.9 MB |
| Test report | Test Report | 2016-11-30 | PDF 2.3 MB |
| Test report | Test Report | 2016-11-30 | PDF 3.1 MB |
| Letter of Agency | Attestation Statements | 2016-11-30 | PDF 297.7 KB |
| Agency Agreement | Cover Letter(s) | 2016-11-30 | PDF 17.1 KB |
| BT Hopping description | Cover Letter(s) | 2016-11-30 | PDF 209.7 KB |
| Bluetooth Hopping Description | Cover Letter(s) | 2016-11-30 | PDF 209.7 KB |
| Confidentiality Request | Cover Letter(s) | 2016-11-30 | PDF 300.2 KB |
| FCC Justification Letter | Cover Letter(s) | 2016-11-30 | PDF 16 KB |
| FCC Justification letter | Cover Letter(s) | 2016-11-30 | PDF 16 KB |
| RF Exposure | RF Exposure Info | 2016-11-30 | PDF 62.6 KB |
| Block Diagram Metadata only | Block Diagram | PDF 113.1 KB | |
| PCB Layout Metadata only | Schematics | PDF 1.6 MB | |
| Parts Placement Metadata only | Schematics | PDF 215.4 KB | |
| Parts placement Metadata only | Schematics | PDF 215.4 KB | |
| Schematics Metadata only | Schematics | PDF 604.3 KB | |
| Operational Description Metadata only | Operational Description | PDF 509.8 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 208.1 KB | |
| Tune-up procedure Metadata only | Parts List/Tune Up Info | PDF 190.7 KB |
Application Information
| Application ID | e8cS+AkhgnrU/wAS+lEaTA== |
|---|---|
| Final Action Date | 2016-11-30 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0024470189 |
| Model | VOLTNX5 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | 3G Mobile Phone |
| Responsible Party | jason yang, lys@locopotel.com |
| Test Firm | philo zhong, Waltek Services(Shenzhen) Co., Ltd., philo@waltek.com.cn |
| TCB Email | Roy.ediss@element.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | RF output power is conducted. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures; SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filling. Body-worn operations are restricted to the specific belt-clips/holsters/accessories tested for this filling, and to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5cm separation between device and the user’s body. End-users must be informed of the body-worn operating requirements for satisfying RF Exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions is 0.77W/kg, 0.86W/kg, 0.89W/kg and 1.14W/kg respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| e8cS+AkhgnrU/wAS+lEaTA== | 2016-11-30 | Original Equipment |
| OMyACq47KwSjyyXY5bsOag== | 2016-11-30 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application OMyACq47KwSjyyXY5bsOag==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Element Materials Technology Warwick Ltd Rothwell Road Warwick Warwick, CV34 5JX United Kingdom |
Date of Grant: 11/30/2016 Application Dated: 11/30/2016 |
| NOBUX, LLC |
| 8600 NW SOUTH RIVER DR 103, |
| MIAMI, FL 33166 |
| Attention: jason yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AEHF-VOLTNX5 |
| Name of Grantee: | NOBUX, LLC |
| Equipment Class: | Digital Transmission System |
| Notes: | 3G Mobile Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.009 | |||
| 15C | 2402.0 - 2480.0 | 0.0003 |
| RF output power is conducted. This device has 20 MHz and 40 MHz bandwidth modes. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures; End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filling. Body-worn operations are restricted to the specific belt-clips/holsters/accessories tested for this filling, and to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5cm separation between device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF Exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions is 0.77W/kg, 0.86W/kg, 0.89W/kg and 1.14W/kg respectively. |
EAS Grant - Application OMyACq47KwSjyyXY5bsOag==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
NOBUX, LLC 8600 NW SOUTH RIVER DR 103, MIAMI, FL 33166 United States |
Date of Grant: 11/30/2016 Application Dated: 11/30/2016 |
| Attention: jason yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AEHF-VOLTNX5 |
| Name of Grantee: | NOBUX, LLC |
| Equipment Class: | Digital Transmission System |
| Notes: | 3G Mobile Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.009 | |||
| 15C | 2402.0 - 2480.0 | 0.0003 |
| RF output power is conducted. This device has 20 MHz and 40 MHz bandwidth modes. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures; End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filling. Body-worn operations are restricted to the specific belt-clips/holsters/accessories tested for this filling, and to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5cm separation between device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF Exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions is 0.77W/kg, 0.86W/kg, 0.89W/kg and 1.14W/kg respectively. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Element Materials Technology Warwick Ltd Rothwell Road Warwick Warwick, CV34 5JX United Kingdom |
Date of Grant: 11/30/2016 Application Dated: 11/30/2016 |
| NOBUX, LLC |
| 8600 NW SOUTH RIVER DR 103, |
| MIAMI, FL 33166 |
| Attention: jason yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AEHF-VOLTNX5 |
| Name of Grantee: | NOBUX, LLC |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | 3G Mobile Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.001 |
| RF output power is conducted. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures; SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filling. Body-worn operations are restricted to the specific belt-clips/holsters/accessories tested for this filling, and to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5cm separation between device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF Exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions is 0.77W/kg, 0.86W/kg, 0.89W/kg and 1.14W/kg respectively. |
EAS Grant - Application e8cS+AkhgnrU/wAS+lEaTA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
NOBUX, LLC 8600 NW SOUTH RIVER DR 103, MIAMI, FL 33166 United States |
Date of Grant: 11/30/2016 Application Dated: 11/30/2016 |
| Attention: jason yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AEHF-VOLTNX5 |
| Name of Grantee: | NOBUX, LLC |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | 3G Mobile Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.001 |
| RF output power is conducted. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures; SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filling. Body-worn operations are restricted to the specific belt-clips/holsters/accessories tested for this filling, and to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5cm separation between device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF Exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions is 0.77W/kg, 0.86W/kg, 0.89W/kg and 1.14W/kg respectively. |
| Mail To: |