FCC ID 2AF2O-FPM20
FP RF MODULE
by Fullpower Technologies, Inc.
Grantee Code: 2AF2O Product Code: FPM20
Latest application date: 2019-07-15
FCC ID Device Details
| FCC ID | 2AF2O-FPM20 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AF2O |
| Product Code | FPM20 |
| Applicant Business | Fullpower Technologies, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | FP RF MODULE |
| Test Firm | CCIC Southern Testing Co., Ltd |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2019-07-15 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2019-07-15 | PDF 792 KB |
| Internal Photos | Internal Photos | 2019-07-15 | PDF 279.9 KB |
| External Photos | External Photos | 2019-07-15 | PDF 279.9 KB |
| Label & Label Location | ID Label/Location Info | 2019-07-15 | PDF 145.8 KB |
| Test Setup photos | Test Setup Photos | 2019-07-15 | PDF 3.7 MB |
| Test Report | Test Report | 2019-07-15 | PDF 3.7 MB |
| Agent Authorization Letter | Cover Letter(s) | 2019-07-15 | PDF 38.2 KB |
| Long Term Confidentiality Request Letter | Cover Letter(s) | 2019-07-15 | PDF 14.4 KB |
| Modular Approval Letter | Cover Letter(s) | 2019-07-15 | PDF 37.8 KB |
| RF Exposure Report | RF Exposure Info | 2019-07-15 | PDF 113.4 KB |
| Block Diagram Metadata only | Block Diagram | PDF 12.1 KB | |
| Schematics Metadata only | Schematics | PDF 642 KB | |
| Operation Description Metadata only | Operational Description | PDF 69.7 KB |
Application Information
| Application ID | 2hagg+9M56g56b3n1VpmZw== |
|---|---|
| Final Action Date | 2019-07-15 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0024889305 |
| Model | FPM20 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | FP RF MODULE |
| Responsible Party | Louis Bouchard, Dir. Engineering, louis.bouchard@fullpower.com |
| Technical Contact | Louis Bouchard, Fullpower Technologies, Inc., louis.bouchard@fullpower.com |
| Test Firm | Zhu Qi, CCIC Southern Testing Co., Ltd, zhuqi@ccic-set.com |
| TCB Email | jenn.warnell@metlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Limited Single Modular Approval |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Limited Modular Approval. Output Power listed is peak conducted. The device supports 20MHz and 40MHz bandwidth. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. The host integrator must follow the integration instructions provided by the module manufacturer and ensure that the composite-system end product complies with the FCC requirements by a technical assessment or evaluation to the FCC rules and to KDB Publication 996369. The module antenna(s) must be installed to meet the RF exposure compliance separation distance of “20 cm” and any additional testing and authorization process as required. The module grantee is responsible for providing the documentation to the system integrator on restrictions of use, for continuing compliance of the module. The host integrator installing this module into their product must ensure that the final composite product complies with the FCC requirements by a technical assessment or evaluation to the FCC rules, including the transmitter operation and should refer to guidance in KDB 996369. The antenna(s) used for this transmitter must not exceed a maximum gain of 18dBi. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 2hagg+9M56g56b3n1VpmZw== | 2019-07-15 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2412-2462 MHz | 0.0530000 | 15C |
Grants
TCB Grant - Application 2hagg+9M56g56b3n1VpmZw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Electrical and Electronic Testing NA, Inc 914 W. Patapsco Avenue Baltimore, MD 21230-3432 |
Date of Grant: 07/15/2019 Application Dated: 07/15/2019 |
| Fullpower Technologies, Inc. |
| 1200 Pacific Ave |
| Ste 300 |
| Santa Cruz, CA 95060 |
| Attention: Louis Bouchard , Dir. Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AF2O-FPM20 |
| Name of Grantee: | Fullpower Technologies, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | FP RF MODULE |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.053 |
| Limited Modular Approval. Output Power listed is peak conducted. The device supports 20MHz and 40MHz bandwidth. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. The host integrator must follow the integration instructions provided by the module manufacturer and ensure that the composite-system end product complies with the FCC requirements by a technical assessment or evaluation to the FCC rules and to KDB Publication 996369. The module antenna(s) must be installed to meet the RF exposure compliance separation distance of 20 cm and any additional testing and authorization process as required. The module grantee is responsible for providing the documentation to the system integrator on restrictions of use, for continuing compliance of the module. The host integrator installing this module into their product must ensure that the final composite product complies with the FCC requirements by a technical assessment or evaluation to the FCC rules, including the transmitter operation and should refer to guidance in KDB 996369. The antenna(s) used for this transmitter must not exceed a maximum gain of 18dBi. |
EAS Grant - Application 2hagg+9M56g56b3n1VpmZw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Fullpower Technologies, Inc. 1200 Pacific Ave Ste 300 Santa Cruz, CA 95060 United States |
Date of Grant: 07/15/2019 Application Dated: 07/15/2019 |
| Attention: Louis Bouchard , Dir. Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AF2O-FPM20 |
| Name of Grantee: | Fullpower Technologies, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | FP RF MODULE |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.053 |
| Limited Modular Approval. Output Power listed is peak conducted. The device supports 20MHz and 40MHz bandwidth. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. The host integrator must follow the integration instructions provided by the module manufacturer and ensure that the composite-system end product complies with the FCC requirements by a technical assessment or evaluation to the FCC rules and to KDB Publication 996369. The module antenna(s) must be installed to meet the RF exposure compliance separation distance of 20 cm and any additional testing and authorization process as required. The module grantee is responsible for providing the documentation to the system integrator on restrictions of use, for continuing compliance of the module. The host integrator installing this module into their product must ensure that the final composite product complies with the FCC requirements by a technical assessment or evaluation to the FCC rules, including the transmitter operation and should refer to guidance in KDB 996369. The antenna(s) used for this transmitter must not exceed a maximum gain of 18dBi. |