FCC ID 2AF4P-CSH17136

UHF RFID Reader

by TERAOKA SEIKO CO.,LTD.

Grantee Code: 2AF4P   Product Code: CSH17136
Latest application date: 2024-01-31

FCC ID Device Details

FCC ID2AF4P-CSH17136
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AF4P
Product CodeCSH17136
Applicant BusinessTERAOKA SEIKO CO.,LTD. 🇯🇵
Related Domains digi.jp
Equipment ClassUHF RFID Reader
Test FirmUL Japan, Inc. SHONAN EMC LABORATORY

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
915.125-927.375 MHzClass II permissive change or modification of presently authorized equipment2024-01-31
915.125-927.375 MHzOriginal Equipment2020-05-20

Exhibits

DocumentTypeAvailableFile
05 User ManualUsers Manual2024-01-31PDF 273.6 KB
05 User ManualUsers Manual2020-05-20PDF 273.3 KB
04 Internal PhotoInternal Photos2024-01-31PDF 1.4 MB
04 Internal Photo1Internal Photos2020-05-20PDF 4.2 MB
04 Internal Photo2Internal Photos2020-05-20PDF 4.3 MB
04 External PhotoExternal Photos2024-01-31PDF 1.5 MB
04 External PhotoExternal Photos2020-05-20PDF 3.4 MB
06 Label and LocationID Label/Location Info2020-05-20PDF 149.5 KB
03 FCC Test Setup Photo_DSSTest Setup Photos2024-01-31PDF 324 KB
03 FCC Test Setup Photo_DSSTest Setup Photos2020-05-20PDF 784.4 KB
03 Antenna SpecificationTest Report2024-01-31PDF 290.3 KB
03 FCC Test Report_DSSTest Report2024-01-31PDF 798.4 KB
03 FCC Test Report_DSSTest Report2020-05-20PDF 2 MB
01 FCC 2.911(d)(5) AttestationAttestation Statements2024-01-31PDF 180.6 KB
01 FCC Agent Attestation_AgentAttestation Statements2024-01-31PDF 198.7 KB
01 FCC Agent Attestation_ApplicantAttestation Statements2024-01-31PDF 219.2 KB
02 FCC Authorization LetterCover Letter(s)2024-01-31PDF 186.2 KB
02 FCC Class II Permissive Change LetterCover Letter(s)2024-01-31PDF 184.3 KB
02 FCC Request for Confidentiality LetterCover Letter(s)2024-01-31PDF 157.7 KB
02 FCC Authorization LetterCover Letter(s)2020-05-20PDF 158 KB
02 FCC Request for Confidentiality LetterCover Letter(s)2020-05-20PDF 135.6 KB
03 FCC RF Exposure_DSSRF Exposure Info2024-01-31PDF 110.2 KB
07 Confidential_Block Diagram Metadata onlyBlock DiagramPDF 102.1 KB
09 Confidential_Schematics Metadata onlySchematicsPDF 315.5 KB
06 Confidential_Theory of Operation-Specification Metadata onlyOperational DescriptionPDF 61 KB
08 Confidential_Theory of Operation Metadata onlyOperational DescriptionPDF 63 KB
08 Confidential_Theory of Operation-Antenna Specification Metadata onlyOperational DescriptionPDF 350.1 KB
08 Confidential_Theory of Operation-Hopping Metadata onlyOperational DescriptionPDF 57.3 KB

Application Information

Application IDJBfyISijBZBbuCCZVOBz1A==
Final Action Date2024-01-31
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0024935785
ModelCSH17136
Frequency Range915.125-927.375 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionUHF RFID Reader
Responsible PartyHideaki Haraguchi, h.haraguchi@digi.jp , +81-3-3752-3001
AgentMiki Miki Miki, UL Japan, Inc., Miki.Murasato@ul.com , 81-463-50-6400
Technical ContactKazutaka Takeyama, UL Japan, Inc., Kazutaka.Takeyama@ul.com , 81-463-50-6400
Test FirmAkio Hayashi, UL Japan, Inc. SHONAN EMC LABORATORY, Akio.Hayashi@ul.com , 81-463-50-6400
TCB EmailLST.FRE.CertNotice@ul.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Short-Term Confidentiality Date03/16/2024
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsClass II Permissive Change to add specific antenna described in the filing. Output power listed is Conducted(Peak). The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons, especially 22 cm for persons with implantable medical devices and must not be co-located or operating in conjunction with any other antenna or transmitter except the conditions shown in this filing and/or in accordance with FCC multi-transmitter product guidelines. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
JBfyISijBZBbuCCZVOBz1A==2024-01-31Class II permissive change or modification of presently authorized equipment
HsTai7Y3Vb0XQI5vSqqWuw==2020-05-20Original Equipment

Equipment Authorization

FrequencyOutputRules
915.125-927.375 MHz0.277300015C

Grants

TCB Grant - Application JBfyISijBZBbuCCZVOBz1A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc.
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 01/31/2024

Application Dated: 01/31/2024
TERAOKA SEIKO CO.,LTD.
5-13-12 KUGAHARA,OHTA-KU
TOKYO, 146-8580
Japan
 
Attention: Hideaki Haraguchi

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AF4P-CSH17136
Name of Grantee:  TERAOKA SEIKO CO.,LTD.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: UHF RFID Reader
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 915.125  -  927.375 0.2773  

Class II Permissive Change to add specific antenna described in the filing. Output power listed is Conducted(Peak). The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons, especially 22 cm for persons with implantable medical devices and must not be co-located or operating in conjunction with any other antenna or transmitter except the conditions shown in this filing and/or in accordance with FCC multi-transmitter product guidelines. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application JBfyISijBZBbuCCZVOBz1A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

TERAOKA SEIKO CO.,LTD.
5-13-12 KUGAHARA,OHTA-KU
TOKYO, 146-8580
Japan
  Date of Grant: 01/31/2024

Application Dated: 01/31/2024
 
Attention: Hideaki Haraguchi

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AF4P-CSH17136
Name of Grantee:  TERAOKA SEIKO CO.,LTD.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: UHF RFID Reader
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 915.125  -  927.375 0.2773  

Class II Permissive Change to add specific antenna described in the filing. Output power listed is Conducted(Peak). The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons, especially 22 cm for persons with implantable medical devices and must not be co-located or operating in conjunction with any other antenna or transmitter except the conditions shown in this filing and/or in accordance with FCC multi-transmitter product guidelines. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.



TCB Grant - Application HsTai7Y3Vb0XQI5vSqqWuw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Japan, Inc.
4383-326 Asama-cho
Ise-shi Mie, 5160021
Japan
Date of Grant: 05/20/2020

Application Dated: 05/20/2020
TERAOKA SEIKO CO.,LTD.
5-13-12 KUGAHARA,OHTA-KU
TOKYO, 146-8580
Japan
 
Attention: Hideaki Haraguchi

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AF4P-CSH17136
Name of Grantee:  TERAOKA SEIKO CO.,LTD.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: UHF RFID Reader
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 915.125  -  927.375 0.2773  

Output power listed is Conducted(Peak). The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons, especially 22 cm for persons with implantable medical devices and must not be co-located or operating in conjunction with any other antenna or transmitter except the conditions shown in this filing and/or in accordance with FCC multi-transmitter product guidelines. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application HsTai7Y3Vb0XQI5vSqqWuw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

TERAOKA SEIKO CO.,LTD.
5-13-12 KUGAHARA,OHTA-KU
TOKYO, 146-8580
Japan
  Date of Grant: 05/20/2020

Application Dated: 05/20/2020
 
Attention: Hideaki Haraguchi

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AF4P-CSH17136
Name of Grantee:  TERAOKA SEIKO CO.,LTD.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: UHF RFID Reader
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 915.125  -  927.375 0.2773  

Output power listed is Conducted(Peak). The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons, especially 22 cm for persons with implantable medical devices and must not be co-located or operating in conjunction with any other antenna or transmitter except the conditions shown in this filing and/or in accordance with FCC multi-transmitter product guidelines. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.



Mail To: