FCC ID 2AF6B-RAK833

LoRa Concentrator Gateway Module

by Shenzhen RAKwireless Technology Co.,Ltd.

Grantee Code: 2AF6B   Product Code: RAK833
Latest application date: 2018-12-28

FCC ID Device Details

FCC ID2AF6B-RAK833
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AF6B
Product CodeRAK833
Applicant BusinessShenzhen RAKwireless Technology Co.,Ltd. 🇨🇳
Related Domains rakwireless.com
Equipment ClassLoRa Concentrator Gateway Module
Test FirmBay Area Compliance Laboratories Corp. (Shenzhen)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
923.3-927.5 MHzOriginal Equipment2018-12-28

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2018-12-28PDF 1.7 MB
Int PhotosInternal Photos2018-12-28PDF 445.7 KB
Ext PhotosExternal Photos2018-12-28PDF 212.9 KB
FCC ID LabelID Label/Location Info2018-12-28PDF 166.5 KB
Setup PhotosTest Setup Photos2018-12-28PDF 354.6 KB
Test ReportTest Report2018-12-28PDF 634.9 KB
Attestation LetterAttestation Statements2018-12-28PDF 78.4 KB
Confidentiality LetterCover Letter(s)2018-12-28PDF 181.6 KB
Module Approval LetterCover Letter(s)2018-12-28PDF 423.1 KB
POACover Letter(s)2018-12-28PDF 685.7 KB
Product Similarity DeclarationCover Letter(s)2018-12-28PDF 49.9 KB
Block Diagram Metadata onlyBlock DiagramPDF 68.3 KB
Schematics Metadata onlySchematicsPDF 683 KB
Operation Description Metadata onlyOperational DescriptionPDF 61.1 KB

Application Information

Application IDobycI72HLvAMkXvFJW+47g==
Final Action Date2018-12-28
Application PurposeOriginal Equipment
Applicant FRN0024961310
ModelRAK833
Frequency Range923.3-927.5 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionLoRa Concentrator Gateway Module
Responsible PartyVivian Xu, Engineer, shasha.xu@rakwireless.com , 19926584202
Test FirmWell Wang, Bay Area Compliance Laboratories Corp. (Shenzhen), qa.sz@baclcorp.com , +86 (0) 755 33320018
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsModular Approval. Output power listed is conducted. This module is approved for use only in the mobile/desktop configurations associated with this filing. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain maybe used with this transmitter. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. OEM integrators and end-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements.

Applications

Application IDDatePurpose
obycI72HLvAMkXvFJW+47g==2018-12-28Original Equipment

Equipment Authorization

FrequencyOutputRules
923.3-927.5 MHz0.008000015C

Grants

TCB Grant - Application obycI72HLvAMkXvFJW+47g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 12/28/2018

Application Dated: 12/28/2018
Shenzhen RAKwireless Technology Co.,Ltd.
Room 506, Building B, New Compark, Pingshan First
Road, Taoyuan Street, Nanshan District,
Shenzhen,
China
 
Attention: Vivian Xu , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AF6B-RAK833
Name of Grantee:  Shenzhen RAKwireless Technology Co.,Ltd.
Equipment Class: Digital Transmission System
Notes: LoRa Concentrator Gateway Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 923.3  -  927.5 0.008  

Modular Approval. Output power listed is conducted. This module is approved for use only in the mobile/desktop configurations associated with this filing. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain maybe used with this transmitter. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. OEM integrators and end-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements.

EAS Grant - Application obycI72HLvAMkXvFJW+47g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen RAKwireless Technology Co.,Ltd.
Room 506, Building B, New Compark, Pingshan First Road, Taoyuan Street, Nanshan District,
Shenzhen,
China
  Date of Grant: 12/28/2018

Application Dated: 12/28/2018
 
Attention: Vivian Xu , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AF6B-RAK833
Name of Grantee:  Shenzhen RAKwireless Technology Co.,Ltd.
Equipment Class: Digital Transmission System
Notes: LoRa Concentrator Gateway Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 923.3  -  927.5 0.008  

Modular Approval. Output power listed is conducted. This module is approved for use only in the mobile/desktop configurations associated with this filing. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain maybe used with this transmitter. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. OEM integrators and end-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements.



Mail To: