FCC ID 2AFB3M-MPD100
MiiS Horus Smart Wound Carer
by Medimaging Integrated Solution Inc.
Grantee Code: 2AFB3 Product Code: MMPD100
Latest application date: 2020-12-02
FCC ID Device Details
| FCC ID | 2AFB3M-MPD100 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AFB3 |
| Product Code | MMPD100 |
| Applicant Business | Medimaging Integrated Solution Inc. 🇹🇼 |
| Related Domains | |
| Equipment Class | MiiS Horus Smart Wound Carer |
| Test Firm | Underwriters Laboratories Taiwan Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Original Equipment | 2020-12-02 |
| 2412-2462 MHz | Original Equipment | 2020-12-02 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| 03_User manual_2AFB3M-MPD100_20201201 | Users Manual | 2020-12-02 | PDF 2.1 MB |
| 11_Internal Photo_2AFB3M-MPD100 | Internal Photos | 2020-12-02 | PDF 5.3 MB |
| 10_External photos_2AFB3M-MPD100 | External Photos | 2020-12-02 | PDF 1.4 MB |
| 02_Label and location_2AFB3M-MPD100 | ID Label/Location Info | 2020-12-02 | PDF 349.4 KB |
| 08_Setup Photos_FCC_2AFB3M-MPD100_20201201 | Test Setup Photos | 2020-12-02 | PDF 1.1 MB |
| 08_Setup Photos_SAR_2AFB3M-MPD100 | Test Setup Photos | 2020-12-02 | PDF 561.1 KB |
| 09_Test Report_SAR_2AFB3M-MPD100 | RF Exposure Info | 2020-12-02 | PDF 4.6 MB |
| 09_Test report 15C_2AFB3M-MPD100_01_20201201 | Test Report | 2020-12-02 | PDF 5.6 MB |
| 09_Test report 15C_2AFB3M-MPD100_02_20201201 | Test Report | 2020-12-02 | PDF 2.3 MB |
| 09_Test report 15E_2AFB3M-MPD100_01_20201201 | Test Report | 2020-12-02 | PDF 2.9 MB |
| 09_Test report 15E_2AFB3M-MPD100_02_20201201 | Test Report | 2020-12-02 | PDF 2.5 MB |
| 01_Authorization Letter_2AFB3M-MPD100 | Cover Letter(s) | 2020-12-02 | PDF 167.4 KB |
| 07_FCC Request for confidentiality letter ( long term )_2AFB3M-MPD100 | Cover Letter(s) | 2020-12-02 | PDF 72.4 KB |
| 12_Declaration Letter_WLAN Ch 12-13_2AFB3M-MPD100 | Cover Letter(s) | 2020-12-02 | PDF 39.2 KB |
| 04_Block Diagram_2AFB3M-MPD100_20201201 Metadata only | Block Diagram | PDF 3 MB | |
| 05_Schematics_2AFB3M-MPD100_20201201 Metadata only | Schematics | PDF 847.5 KB | |
| Module_Schematic_20201030 Metadata only | Schematics | PDF 924 KB | |
| 06_Operation Description_2AFB3M-MPD100_20201202 Metadata only | Operational Description | PDF 357.6 KB | |
| 13_5G Software Security_2AFB3M-MPD100_20201201 Metadata only | Operational Description | PDF 515.5 KB |
Application Information
| Application ID | W4K1rLYbd5h1Ck8CSTVHcQ== |
|---|---|
| Final Action Date | 2020-12-02 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0024731028 |
| Model | M-MPD100 |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | MiiS Horus Smart Wound Carer |
| Responsible Party | Luu Hsu, luu@miis.com.tw |
| Test Firm | Roy Chen, Underwriters Laboratories Taiwan Co., Ltd., Roy.Chen@ul.com |
| TCB Email | LST.FRE.CertNotice@ul.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power is conducted. This device has 20 MHz, 40 MHz and 80 MHz bandwidth modes. The highest reported SAR for body-worn accessory and simultaneous transmission exposure conditions is 1.09 W/kg, and 1.09 W/kg, respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| W4K1rLYbd5h1Ck8CSTVHcQ== | 2020-12-02 | Original Equipment |
| TjSb0RAcx8yhihoXF/PmhQ== | 2020-12-02 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application W4K1rLYbd5h1Ck8CSTVHcQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 12/02/2020 Application Dated: 12/02/2020 |
| Medimaging Integrated Solution Inc. |
| 3F, No. 24-2, Industry E. Rd. IV, |
| Hsinchu Science Park |
| Hsinchu, 30077 Taiwan |
| Attention: Luu Hsu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AFB3M-MPD100 |
| Name of Grantee: | Medimaging Integrated Solution Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | MiiS Horus Smart Wound Carer |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.015 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.013 |
| Power is conducted. This device has 20 MHz, 40 MHz and 80 MHz bandwidth modes. The highest reported SAR for body-worn accessory and simultaneous transmission exposure conditions is 1.09 W/kg, and 1.09 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application W4K1rLYbd5h1Ck8CSTVHcQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Medimaging Integrated Solution Inc. 3F, No. 24-2, Industry E. Rd. IV, Hsinchu Science Park Hsinchu, 30077 Taiwan |
Date of Grant: 12/02/2020 Application Dated: 12/02/2020 |
| Attention: Luu Hsu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AFB3M-MPD100 |
| Name of Grantee: | Medimaging Integrated Solution Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | MiiS Horus Smart Wound Carer |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.015 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.013 |
| Power is conducted. This device has 20 MHz, 40 MHz and 80 MHz bandwidth modes. The highest reported SAR for body-worn accessory and simultaneous transmission exposure conditions is 1.09 W/kg, and 1.09 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 12/02/2020 Application Dated: 12/02/2020 |
| Medimaging Integrated Solution Inc. |
| 3F, No. 24-2, Industry E. Rd. IV, |
| Hsinchu Science Park |
| Hsinchu, 30077 Taiwan |
| Attention: Luu Hsu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AFB3M-MPD100 |
| Name of Grantee: | Medimaging Integrated Solution Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | MiiS Horus Smart Wound Carer |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.081 |
| Power is conducted. This device has 20 MHz and 40 MHz bandwidth modes. The highest reported SAR for body-worn accessory and simultaneous transmission exposure conditions is 1.10 W/kg, and 1.10 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application TjSb0RAcx8yhihoXF/PmhQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Medimaging Integrated Solution Inc. 3F, No. 24-2, Industry E. Rd. IV, Hsinchu Science Park Hsinchu, 30077 Taiwan |
Date of Grant: 12/02/2020 Application Dated: 12/02/2020 |
| Attention: Luu Hsu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AFB3M-MPD100 |
| Name of Grantee: | Medimaging Integrated Solution Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | MiiS Horus Smart Wound Carer |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.081 |
| Power is conducted. This device has 20 MHz and 40 MHz bandwidth modes. The highest reported SAR for body-worn accessory and simultaneous transmission exposure conditions is 1.10 W/kg, and 1.10 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |