FCC ID 2AFGR-QT2
Microinverter
by Altenergy Power System Inc.
Grantee Code: 2AFGR Product Code: QT2
Latest application date: 2022-06-23
FCC ID Device Details
| FCC ID | 2AFGR-QT2 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AFGR |
| Product Code | QT2 |
| Applicant Business | Altenergy Power System Inc. 🇨🇳 |
| Related Domains | |
| Equipment Class | Microinverter |
| Test Firm | Cerpass Technology Corporation(Cerpass Laboratory) |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2405-2480 MHz | Original Equipment | 2022-06-23 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2022-12-20 | PDF 2 MB |
| Internal photos | Internal Photos | 2022-12-20 | PDF 667.2 KB |
| External photos | External Photos | 2022-12-20 | PDF 604.5 KB |
| ID label and location | ID Label/Location Info | 2022-06-23 | PDF 2.2 MB |
| Test setup photos | Test Setup Photos | 2022-12-20 | PDF 234.2 KB |
| Test reports | Test Report | 2022-06-23 | PDF 1.4 MB |
| Model family declaration | Attestation Statements | 2022-06-23 | PDF 47.6 KB |
| Confidentiality | Cover Letter(s) | 2022-06-23 | PDF 63.3 KB |
| Letter Authorization | Cover Letter(s) | 2022-06-23 | PDF 128.3 KB |
| RF Exposure | RF Exposure Info | 2022-06-23 | PDF 178.6 KB |
| Block Diagram Metadata only | Block Diagram | PDF 66.5 KB | |
| Schematics Metadata only | Schematics | PDF 695.5 KB | |
| Operational Description Metadata only | Operational Description | PDF 95.1 KB |
Application Information
| Application ID | Jq3XzsVZ8eCOnYn9NFJuaQ== |
|---|---|
| Final Action Date | 2022-06-23 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0024770307 |
| Model | QT2 |
| Frequency Range | 2405-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Microinverter |
| Responsible Party | Guofeng Jiang, Manager, guofeng.jiang@apsystems.cn |
| Technical Contact | Guofeng Jiang, Altenergy Power System Inc., guofeng.jiang@apsystems.cn |
| Non-Technical Contact | Karen Tang, Cerpass Technology Corporation(Cerpass Laboratory), Karent@cerpass.net |
| Test Firm | Miro Chueh, Cerpass Technology Corporation(Cerpass Laboratory), miroc@cerpass.net |
| TCB Email | elabscert@applus.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 12/20/2022 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| Jq3XzsVZ8eCOnYn9NFJuaQ== | 2022-06-23 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2405-2480 MHz | 0.0091600 | 15C |
Grants
TCB Grant - Application Jq3XzsVZ8eCOnYn9NFJuaQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 06/23/2022 Application Dated: 06/23/2022 |
| Altenergy Power System Inc. |
| No.1, Yatai Road, Jiaxing Zhejiang |
| 314050 P.R. China |
| Jiaxing, China |
| Attention: Guofeng Jiang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AFGR-QT2 |
| Name of Grantee: | Altenergy Power System Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Microinverter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2405.0 - 2480.0 | 0.00916 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application Jq3XzsVZ8eCOnYn9NFJuaQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Altenergy Power System Inc. No.1, Yatai Road, Jiaxing Zhejiang 314050 P.R. China Jiaxing, China |
Date of Grant: 06/23/2022 Application Dated: 06/23/2022 |
| Attention: Guofeng Jiang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AFGR-QT2 |
| Name of Grantee: | Altenergy Power System Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Microinverter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2405.0 - 2480.0 | 0.00916 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |