FCC ID 2AFOILOR

LoRa based Ball valve Actuator security system

by Triple Plus

Grantee Code: 2AFOI   Product Code: LOR
Latest application date: 2019-10-16

FCC ID Device Details

FCC ID2AFOILOR
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AFOI
Product CodeLOR
Applicant BusinessTriple Plus 🇮🇱
Related Domains tripleplus.io
Equipment ClassLoRa based Ball valve Actuator security system
Test FirmHermon Laboratories Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
919.813 MHzOriginal Equipment2019-10-16

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2019-10-16PDF 1.5 MB
Internal PhotosInternal Photos2019-10-16PDF 404.7 KB
External PhotosExternal Photos2019-10-16PDF 162.5 KB
ID Label/Location InfoID Label/Location Info2019-10-16PDF 152.3 KB
Operational DescriptionOperational Description2019-10-16PDF 385.9 KB
Test Setup PhotosTest Setup Photos2019-10-16PDF 314 KB
Test ReportTest Report2019-10-16PDF 1.5 MB
Cover letterCover Letter(s)2019-10-16PDF 137.6 KB
confidentialityCover Letter(s)2019-10-16PDF 317 KB
RF exposure reportRF Exposure Info2019-10-16PDF 121.5 KB
Block Diagram Metadata onlyBlock DiagramPDF 153.1 KB
Schematics Metadata onlySchematicsPDF 131.6 KB

Application Information

Application IDs3+1VIlzqeUK3TBsZeZ2pQ==
Final Action Date2019-10-16
Application PurposeOriginal Equipment
Applicant FRN0024831810
ModelLOR
Frequency Range919.813 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionLoRa based Ball valve Actuator security system
Responsible PartyMichael Isakov, CEO, michael.isakov@tripleplus.io , +972-72-2211370
Technical ContactMichael Nikishin, Hermon Laboratories Ltd., nikishin@hermonlabs.com , 972 4626 8440
Non-Technical ContactYuval Abraham, Triple Plus Ltd, yuval.abraham@tripleplus.io , 972722211370
Test FirmGeorge Shleimovich, Hermon Laboratories Ltd., George@HERMONLABS.com , 97246268468
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
s3+1VIlzqeUK3TBsZeZ2pQ==2019-10-16Original Equipment

Equipment Authorization

FrequencyOutputRules
919.813 MHz0.038000015C

Grants

TCB Grant - Application s3+1VIlzqeUK3TBsZeZ2pQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 10/16/2019

Application Dated: 10/16/2019
Triple Plus
5 Hamada St. South Hi Tech Park
P.O. Box 507,
Yokneam, 2069200
Israel
 
Attention: Michael Isakov , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AFOILOR
Name of Grantee:  Triple Plus
Equipment Class: Digital Transmission System
Notes: LoRa based Ball valve Actuator security system
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 919.8126  -  919.8126 0.038  

Power Output is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance.

EAS Grant - Application s3+1VIlzqeUK3TBsZeZ2pQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Triple Plus
5 Hamada St. South Hi Tech Park P.O. Box 507,
Yokneam, 2069200
Israel
  Date of Grant: 10/16/2019

Application Dated: 10/16/2019
 
Attention: Michael Isakov , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AFOILOR
Name of Grantee:  Triple Plus
Equipment Class: Digital Transmission System
Notes: LoRa based Ball valve Actuator security system
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 919.8126  -  919.8126 0.038  

Power Output is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance.



Mail To: