FCC ID 2AGCP-VCDT711N

Visual Coaching Device (VCD)

by Varian Medical Systems, Inc.

Grantee Code: 2AGCP   Product Code: VCDT711N
Latest application date: 2015-12-14

Device Images

FCC ID Device Details

FCC ID2AGCP-VCDT711N
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AGCP
Product CodeVCDT711N
Applicant BusinessVarian Medical Systems, Inc. 🇺🇸
Related Domains varian.com
Equipment ClassVisual Coaching Device (VCD)
Test FirmCTC advanced GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2015-12-14

Exhibits

DocumentTypeAvailableFile
UserManual.pdfUsers Manual2015-12-14PDF 1.6 MB
UserManual_Safety.pdfUsers Manual2015-12-14PDF 359.2 KB
InternalPhotos.pdfInternal Photos2015-12-14PDF 674.7 KB
ExternalPhotos.pdfExternal Photos2015-12-14PDF 933.7 KB
Label.pdfID Label/Location Info2015-12-14PDF 470.4 KB
TestSetupPhotos.pdfTest Setup Photos2015-12-14PDF 833.6 KB
TestSetupPhotos_RFExposure.pdfTest Setup Photos2015-12-14PDF 393.7 KB
TestReport.pdfTest Report2015-12-14PDF 3.5 MB
CoverLetter ConfidentialityRequestLetter.pdfCover Letter(s)2015-12-14PDF 141.5 KB
Software Configuration Description.pdfCover Letter(s)2015-12-14PDF 69.5 KB
RFExposure.pdfRF Exposure Info2015-12-14PDF 949.9 KB
RFExposure_Caldata.pdfRF Exposure Info2015-12-14PDF 3 MB
Block Diagram VCD.pdf Metadata onlyBlock DiagramPDF 70.5 KB
Schematics.pdf Metadata onlySchematicsPDF 293.1 KB
OperationalDescription.pdf Metadata onlyOperational DescriptionPDF 83 KB
TuneUpInfo.pdf Metadata onlyParts List/Tune Up InfoPDF 15 KB

Application Information

Application IDBJvz2OeQly0oJ//ZsGrcdg==
Final Action Date2015-12-14
Application PurposeOriginal Equipment
Applicant FRN0025005877
ModelVCDT711N
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionVisual Coaching Device (VCD)
Responsible PartySuren Soman, Product Compliance Manager, surendra.soman@varian.com , 1.650.424.6942
Test FirmGerald Schmidt, CTC advanced GmbH, mail@ctcadvanced.com , 49-681-598-0
TCB EmailOliver.Kneip@cetecom.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is average conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR is 0.19 W/kg.

Applications

Application IDDatePurpose
BJvz2OeQly0oJ//ZsGrcdg==2015-12-14Original Equipment

Equipment Authorization

FrequencyOutputRules
2412-2462 MHz0.04915C
2422-2452 MHz0.02315C

Grants

TCB Grant - Application BJvz2OeQly0oJ//ZsGrcdg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CTC advanced GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 12/14/2015

Application Dated: 12/14/2015
Varian Medical Systems, Inc.
Oncology Systems
3100 Hansen Way
Palo Alto, CA 94304-1038
 
Attention: Suren Soman , Product Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AGCP-VCDT711N
Name of Grantee:  Varian Medical Systems, Inc.
Equipment Class: Digital Transmission System
Notes: Visual Coaching Device (VCD)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.049  
15C 2422.0  -  2452.0 0.023  

Output power listed is average conducted.

This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode.

End users must be informed of the body worn requirements for satisfying RF Exposure compliance.

The highest reported SAR is 0.19 W/kg.


EAS Grant - Application BJvz2OeQly0oJ//ZsGrcdg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Varian Medical Systems, Inc.
Oncology Systems 3100 Hansen Way
Palo Alto, CA 94304-1038
United States
  Date of Grant: 12/14/2015

Application Dated: 12/14/2015
 
Attention: Suren Soman , Product Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AGCP-VCDT711N
Name of Grantee:  Varian Medical Systems, Inc.
Equipment Class: Digital Transmission System
Notes: Visual Coaching Device (VCD)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.049  
15C 2422.0  -  2452.0 0.023  

Output power listed is average conducted.

This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode.

End users must be informed of the body worn requirements for satisfying RF Exposure compliance.

The highest reported SAR is 0.19 W/kg.



Mail To: