FCC ID 2AGER-XG1

Global Mobile WiFi Travel Router

by XCom Global, Inc.

Grantee Code: 2AGER   Product Code: XG1
Latest application date: 2016-01-29

Device Images

FCC ID Device Details

FCC ID2AGER-XG1
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AGER
Product CodeXG1
Applicant BusinessXCom Global, Inc. 🇺🇸
Related Domains xcomglobal.com
Equipment ClassGlobal Mobile WiFi Travel Router
Test FirmShenzhen Zhongjian Nanfang Testing Co.,Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2016-01-29
709-711 MHzOriginal Equipment2016-01-29

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2016-01-29PDF 757.7 KB
Int photoInternal Photos2016-01-29PDF 1.1 MB
Ext photoExternal Photos2016-01-29PDF 499.4 KB
ID labelID Label/Location Info2016-01-29PDF 115.9 KB
MB setup photoTest Setup Photos2016-01-29PDF 196 KB
Test setup photo_WiFiTest Setup Photos2016-01-29PDF 290.4 KB
CCIS15110085001 MBTest Report2016-01-29PDF 1.3 MB
CCIS15110085004 LTE(page1-140)Test Report2016-01-29PDF 5 MB
CCIS15110085004 LTE(page141-313)Test Report2016-01-29PDF 3.7 MB
Test report_WiFiTest Report2016-01-29PDF 3.3 MB
Confidential request letterCover Letter(s)2016-01-29PDF 56.3 KB
POACover Letter(s)2016-01-29PDF 72.4 KB
WiFi ch 12-13 letterCover Letter(s)2016-01-29PDF 182.1 KB
SARRF Exposure Info2016-01-29PDF 5.3 MB

Application Information

Application IDQ2T7m0BBQA7COGj+FHKcVQ==
Final Action Date2016-01-29
Application PurposeOriginal Equipment
Applicant FRN0025024688
Model-XG1
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionGlobal Mobile WiFi Travel Router
Responsible PartyJoseph Fennell, Joe@xcomglobal.com , 8582228242
Test FirmBruce Zhang, Shenzhen Zhongjian Nanfang Testing Co.,Ltd, bruce.zhang@ccis-cb.com , 86-755-23118282
TCB EmailTCB@siemic.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is the maximum conducted output power. For body worn operation, this phone has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the handset a minimum of 10 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. Highest reported SAR for, Body-worn accessory, , Simultaneous Transmission are: 0.10 W/kg, 1.15 W/kg,

Applications

Application IDDatePurpose
Q2T7m0BBQA7COGj+FHKcVQ==2016-01-29Original Equipment
LFXt8lNM+LLyykRWK1J2ug==2016-01-29Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
709-711 MHz0.13270.205634ppm10M8G7D27
709-711 MHz0.13680.208451ppm10M8W7D27
824.2-848.8 MHz0.64860.181688ppm328KG7W22H
826.4-846.6 MHz0.3540.198422ppm4M74F9W22H
1710.7-1754.3 MHz0.14290.112554ppm1M64G7D27
1720-1745 MHz0.13270.093506ppm21M0G7D27
1720-1745 MHz0.13960.084848ppm20M9W7D27
1850.2-1909.8 MHz0.33270.094149ppm314KGXW24E
1850.2-1909.8 MHz0.25470.081915ppm310KG7W24E
1852.4-1907.6 MHz0.32360.077128ppm4M78F9W24E
2412-2462 MHz0.045700015C
2510-2560 MHz0.05570.069034ppm21M9G7D27
2510-2560 MHz0.05260.050888ppm21M3W7D27

Grants

TCB Grant - Application Q2T7m0BBQA7COGj+FHKcVQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Siemic Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 01/29/2016

Application Dated: 01/28/2016
XCom Global, Inc.
5910 pacific center blvd
Suite 320
San diego, CA 92121
 
Attention: Joseph Fennell

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AGER-XG1
Name of Grantee:  XCom Global, Inc.
Equipment Class: Digital Transmission System
Notes: Global Mobile WiFi Travel Router
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.0457  

Power listed is the maximum conducted output power. For body worn operation, this phone has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the handset a minimum of 10 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. Highest reported SAR for, Body-worn accessory, , Simultaneous Transmission are: 0.10 W/kg, 1.15 W/kg,

EAS Grant - Application Q2T7m0BBQA7COGj+FHKcVQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

XCom Global, Inc.
5910 pacific center blvd Suite 320
San diego, CA 92121
United States
  Date of Grant: 01/29/2016

Application Dated: 01/28/2016
 
Attention: Joseph Fennell

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AGER-XG1
Name of Grantee:  XCom Global, Inc.
Equipment Class: Digital Transmission System
Notes: Global Mobile WiFi Travel Router
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.0457  

Power listed is the maximum conducted output power. For body worn operation, this phone has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the handset a minimum of 10 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. Highest reported SAR for, Body-worn accessory, , Simultaneous Transmission are: 0.10 W/kg, 1.15 W/kg,



TCB Grant - Application LFXt8lNM+LLyykRWK1J2ug==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Siemic Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 01/29/2016

Application Dated: 01/28/2016
XCom Global, Inc.
5910 pacific center blvd
Suite 320
San diego, CA 92121
 
Attention: Joseph Fennell

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AGER-XG1
Name of Grantee:  XCom Global, Inc.
Equipment Class: PCS Licensed Transmitter worn on body
Notes: Global Mobile WiFi Travel Router
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.8035 0.217547  PM 320KGXW
22H 824.2  -  848.8 0.6486 0.181688  PM 328KG7W
24E 1850.2  -  1909.8 0.3327 0.094149  PM 314KGXW
24E 1850.2  -  1909.8 0.2547 0.081915  PM 310KG7W
22H 826.4  -  846.6 0.354 0.198422  PM 4M74F9W
24E 1852.4  -  1907.6 0.3236 0.077128  PM 4M78F9W
27 1710.7  -  1754.3 0.1429 0.112554  PM 1M64G7D
27 1720.0  -  1745.0 0.1327 0.093506  PM 21M0G7D
27 1720.0  -  1745.0 0.1396 0.084848  PM 20M9W7D
27 2510.0  -  2560.0 0.0557 0.069034  PM 21M9G7D
27 2510.0  -  2560.0 0.0526 0.050888  PM 21M3W7D
27 709.0  -  711.0 0.1327 0.205634  PM 10M8G7D
27 709.0  -  711.0 0.1368 0.208451  PM 10M8W7D

Output power listed is ERP for Part 22 and EIRP for Part 24,27L/M, For body worn operation, this phone has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the handset a minimum of 10 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. Highest reported SAR for Body-worn accessory, Simultaneous Transmission are: 1.04 W/kg, 1.15W/kg, This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations.

EAS Grant - Application LFXt8lNM+LLyykRWK1J2ug==

FCC Home | Search | Updates | E-Filing | Initiatives | For Consumers | Find People
Office of Engineering and Technology
  FCC > FCC E-filing > OET Application Error Page FCC Site Map
The Following Error(s) Occurred While Retrieving The Requested Page:

Date and time of error: Sat Jan 30 17:30:00 EST 2016 
Requester's browser type: python-requests/2.7.0 CPython/2.7.6 Linux/3.13.0-62-generic 
Called from:  
Parameters specified: mode=COPY&RequestTimeout=500&tcb_code=&application_id=LFXt8lNM%2BLLyykRWK1J2ug%3D%3D&fcc_id=2AGER-XG1 
Diagnostic information: Error Executing Database Query. JZ0C0: Connection is already closed.
The error occurred on line 26. 

Please report this error to FCC OET Systems Support

 



Federal Communications Commission
445 12th Street, SW
Washington, DC 20554
More FCC Contact Information...
Phone:  888-CALL-FCC (225-5322)
TTY:  888-TELL-FCC (835-5322)
Fax:  202-418-0232
E-mail:  fccinfo@fcc.gov
- Web Policies & Privacy Statement
- Customer Service Standards
- Freedom of Information Act