FCC ID 2AH3O-CLM

CLM

by Rapsodo Pte Ltd

Grantee Code: 2AH3O   Product Code: CLM
Latest application date: 2026-10-27

FCC ID Device Details

FCC ID2AH3O-CLM
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AH3O
Product CodeCLM
Applicant BusinessRapsodo Pte Ltd 🇸🇬
Related Domains rapsodo.com
Equipment ClassCLM
Test FirmShenzhen LGT Test Service Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2026-10-27
2412-2462 MHzOriginal Equipment2026-10-27
5745-5825 MHzOriginal Equipment2026-10-27

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2026-10-27PDF 730.6 KB
Label InformationID Label/Location Info2026-10-27PDF 138.7 KB
Antenna ReportTest Report2026-10-27PDF 648.6 KB
Test ReportTest Report2026-10-27PDF 5.8 MB
Test ReportTest Report2026-10-27PDF 3.5 MB
Test ReportTest Report2026-10-27PDF 1.2 MB
Attestation Statements of US Agent for Service of Process, 2.911(d)(7)Attestation Statements2026-10-27PDF 142.1 KB
Attestation of Covered Equipment, 2.911(d)(5)(i)(ii)Attestation Statements2026-10-27PDF 106 KB
Agent Authorization Letter TemplateCover Letter(s)2026-10-27PDF 188 KB
Short & Long Term Confidentiality RequestCover Letter(s)2026-10-27PDF 85.3 KB
Software Configuration Control DeclarationCover Letter(s)2026-10-27PDF 91.4 KB
RF Exposure ReportRF Exposure Info2026-10-27PDF 429.2 KB
Internal Photos Metadata onlyInternal Photos2027-04-25PDF 3.5 MB
External Photos Metadata onlyExternal Photos2027-04-25PDF 1,023.9 KB
Test Setup Photos Metadata onlyTest Setup Photos2027-04-25PDF 261.9 KB
BLOCK Metadata onlyBlock DiagramPDF 4.8 MB
SCH Metadata onlySchematicsPDF 4.2 MB
Operational Description Metadata onlyOperational DescriptionPDF 120.9 KB
SOFTWARE SECURITY REQUIREMENTS FOR U-NII DEVICES Metadata onlySDR Software/Security Info.PDF 137.4 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 630.2 KB

Application Information

Application IDXmh7CAzUQETrQFmwhp/gxw==
Final Action Date2026-10-27
Application PurposeOriginal Equipment
Applicant FRN0025501990
ModelCLM
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionCLM
Responsible PartyBatuhan Okur, batuhan@rapsodo.com , 6598206688
Technical ContactRapsodo Pte Ltd, batuhan@rapsodo.com
Non-Technical ContactJon Tutuncu, Rapsodo Inc, accounting@rapsodo.com
Test FirmWen Wen, Shenzhen LGT Test Service Co., Ltd., qa@lgt-cert.com , 0755-89668180
TCB Emailanezam@qai.org
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
Xmh7CAzUQETrQFmwhp/gxw==2026-10-27Original Equipment
BMyR5hoGFIJHaO3Q4pU0bw==2026-10-27Original Equipment
/eoyWCTwWfFahjFxjNaTsg==2026-10-27Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.008915CCC
2402-2480 MHz0.005715CCC
2412-2462 MHz0.048615CCC MO
5180-5240 MHz0.029915ECC MO
5260-5320 MHz0.026115ECC MO ND
5500-5700 MHz0.0315ECC MO ND
5745-5825 MHz0.026715ECC MO

Grants

TCB Grant - Application Xmh7CAzUQETrQFmwhp/gxw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  QAI LABORATORIES LTD
3980 North Fraser Way
Burnaby, BC, V5J5K5
Canada
Date of Grant: 10/27/2026

Application Dated: 10/27/2026
Rapsodo Pte Ltd
Blk 20 Ayer Rajah Crescent, #08-05
singapore, 139964
Singapore
 
Attention: Batuhan Okur , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AH3O-CLM
Name of Grantee:  Rapsodo Pte Ltd
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CLM
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0089  

Power listed is the maximum conducted output power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application BMyR5hoGFIJHaO3Q4pU0bw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  QAI LABORATORIES LTD
3980 North Fraser Way
Burnaby, BC, V5J5K5
Canada
Date of Grant: 10/27/2026

Application Dated: 10/27/2026
Rapsodo Pte Ltd
Blk 20 Ayer Rajah Crescent, #08-05
singapore, 139964
Singapore
 
Attention: Batuhan Okur , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AH3O-CLM
Name of Grantee:  Rapsodo Pte Ltd
Equipment Class: Digital Transmission System
Notes: CLM
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0057  
CC MO 15C 2412.0  -  2462.0 0.0486  

Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application /eoyWCTwWfFahjFxjNaTsg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  QAI LABORATORIES LTD
3980 North Fraser Way
Burnaby, BC, V5J5K5
Canada
Date of Grant: 10/27/2026

Application Dated: 10/27/2026
Rapsodo Pte Ltd
Blk 20 Ayer Rajah Crescent, #08-05
singapore, 139964
Singapore
 
Attention: Batuhan Okur , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AH3O-CLM
Name of Grantee:  Rapsodo Pte Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: CLM
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.0299  
CC MO ND 15E 5260.0  -  5320.0 0.0261  
CC MO ND 15E 5500.0  -  5700.0 0.03  
CC MO 15E 5745.0  -  5825.0 0.0267  

Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).