FCC ID 2AH7L-BB1R

PM7000 series flush mount energy meter

by Schneider Electric Industrie SAS

Grantee Code: 2AH7L   Product Code: BB1R
Latest application date: 2026-10-05

FCC ID Device Details

FCC ID2AH7L-BB1R
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AH7L
Product CodeBB1R
Applicant BusinessSchneider Electric Industrie SAS 🇫🇷
Related Domains se.com
Equipment ClassPM7000 series flush mount energy meter
Test FirmUL LLC/UL India Private Limited

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2026-10-05

Exhibits

DocumentTypeAvailableFile
PM7100_PM7200_PM7300_User Manual[1]_Part1Users Manual2026-10-05PDF 4.4 MB
PM7100_PM7200_PM7300_User Manual[1]_Part2Users Manual2026-10-05PDF 3.6 MB
STC_Instruction Sheet_PKR39369-03_Part1Users Manual2026-10-05PDF 4.7 MB
STC_Instruction Sheet_PKR39369-03_Part2Users Manual2026-10-05PDF 4.8 MB
STC_Instruction Sheet_PKR39369-03_Part3Users Manual2026-10-05PDF 541 KB
EXTERNAL PHOTO DOCUMENT_RS485_V1.1External Photos2026-10-05PDF 634.9 KB
LABEL EXIBIT_FINAL_RS485_021026ID Label/Location Info2026-10-05PDF 759.3 KB
TEST SETUP PHOTOGRAPHS_DOC_V1.1_RS485Test Setup Photos2026-10-05PDF 3 MB
ANTENNA DATA SHEETTest Report2026-10-05PDF 568.9 KB
FCC_ISED_BLE RF REPORT_RS485_VARIENT_4791483632_V1.1_PART 1Test Report2026-10-05PDF 4.5 MB
FCC_ISED_BLE RF REPORT_RS485_VARIENT_4791483632_V1.1_PART 2Test Report2026-10-05PDF 5.8 MB
FCC_ISED_BLE RF REPORT_RS485_VARIENT_4791483632_V1.1_PART 3Test Report2026-10-05PDF 4.3 MB
18_FCC 2.911[d][5] Attestation_2AH7L-BB1RAttestation Statements2026-10-05PDF 293.9 KB
FCC Agent for service Attestation from Agent_RS485Attestation Statements2026-10-05PDF 178.7 KB
FCC Agent for service Attestation from Applicant_RS485Attestation Statements2026-10-05PDF 129.3 KB
01_FCC_Authorization Letter_2AH7L-BB1RCover Letter(s)2026-10-05PDF 311.1 KB
07_FCC Request for confidentiality letter_250926Cover Letter(s)2026-10-05PDF 176.7 KB
RS485_Letter head document for simalrility and difference_BLE_250926Cover Letter(s)2026-10-05PDF 381 KB
FCC_MPE REPORT_RS485 VARIENT_4791483632_V1.1RF Exposure Info2026-10-05PDF 741.7 KB
INTERNAL PHOTO DOCUMENT_RS485_V1.1 Metadata onlyInternal Photos2026-12-31PDF 2.7 MB
RS485_Internal Block diagram with Crystal Frequencies Metadata onlyBlock DiagramPDF 181.5 KB
STC_External Block Diagram_RS485 4DI Metadata onlyBlock DiagramPDF 158 KB
PS 4DI PCB Layers_V08 Metadata onlySchematicsPDF 258.1 KB
RS485 Superset PCB Layers_V09 Metadata onlySchematicsPDF 1.2 MB
STC_GENERIC SCHEMATIC_PKR1645018_A60_08 Metadata onlySchematicsPDF 563.1 KB
STC_GENERIC SCHEMATIC_PKR1992220_A60_09 Metadata onlySchematicsPDF 1.5 MB
Operational Description for wireless technology-BB1.1_RS485 varient Metadata onlyOperational DescriptionPDF 206.6 KB

Application Information

Application IDIVnL7oJBMCpwQWptOqJY6w==
Final Action Date2026-10-05
Application PurposeOriginal Equipment
Applicant FRN0025527185
ModelBB1R
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionPM7000 series flush mount energy meter
Responsible PartyPavana S, pavana.s@se.com , +917760972017
Technical ContactSuresh G N, UL INIDA PRIVATE LIMITED, Suresh.GN@ul.com , 918041384486
Non-Technical ContactChristo Thomas, Schneider Electric USA Inc, christo.thomas@se.com
Test FirmRick Titus, UL LLC/UL India Private Limited, Rick.A.Titus@ul.com , 18472092945
TCB EmailLST.FRE.CertNotice@ul.comLST.FRE.CertNotice
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
IVnL7oJBMCpwQWptOqJY6w==2026-10-05Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.00615C

Grants

TCB Grant - Application IVnL7oJBMCpwQWptOqJY6w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc.
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 10/05/2026

Application Dated: 10/05/2026
Schneider Electric Industrie SAS
31 rue Pierre Mendes France, eybens
grenoble cedex 9, 38050
France
 
Attention: Pavana S , Deputy General Manager - Certification

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AH7L-BB1R
Name of Grantee:  Schneider Electric Industrie SAS
Equipment Class: Digital Transmission System
Notes: PM7000 series flush mount energy meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.006  

Output power listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.