FCC ID 2AHBN-AP24
802.11ax 6E 2+2+2 Wireless Access Point
by Juniper Networks, Inc.
Grantee Code: 2AHBN Product Code: AP24
Latest application date: 2026-06-12
FCC ID Device Details
| FCC ID | 2AHBN-AP24 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AHBN |
| Product Code | AP24 |
| Applicant Business | Juniper Networks, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | 802.11ax 6E 2+2+2 Wireless Access Point |
| Test Firm | Sporton International Inc. Hsinhua Laboratory |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 6535-6855 MHz | Original Equipment | 2026-06-12 |
| 5955-7095 MHz | Original Equipment | 2023-05-19 |
| 5180-5240 MHz | Original Equipment | 2023-05-19 |
| 2402-2480 MHz | Original Equipment | 2023-05-19 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2026-06-12 | PDF 2.4 MB |
| User Manual | Users Manual | 2023-05-19 | PDF 2.2 MB |
| Internal Photos | Internal Photos | 2026-06-12 | PDF 5.5 MB |
| Internal Photos | Internal Photos | 2023-05-19 | PDF 5.5 MB |
| External Photos | External Photos | 2026-06-12 | PDF 609.7 KB |
| External Photos | External Photos | 2023-05-19 | PDF 744.1 KB |
| Label Information | ID Label/Location Info | 2026-06-12 | PDF 136 KB |
| Label | ID Label/Location Info | 2023-05-19 | PDF 136 KB |
| OpDes General Description GPS NDA | Operational Description | 2026-06-12 | PDF 176.4 KB |
| OpDes General Description Non-GPS NDA | Operational Description | 2026-06-12 | PDF 86 KB |
| TSUP WLAN 6G | Test Setup Photos | 2026-06-12 | PDF 1.6 MB |
| Antenna Test Photos | Test Setup Photos | 2023-05-19 | PDF 482.5 KB |
| Test Photos 2.4G | Test Setup Photos | 2023-05-19 | PDF 1.1 MB |
| Test Photos 5G | Test Setup Photos | 2023-05-19 | PDF 1.3 MB |
| Test Photos 6G | Test Setup Photos | 2023-05-19 | PDF 1.9 MB |
| Test Photos DFS | Test Setup Photos | 2023-05-19 | PDF 195.8 KB |
| Test Photos LE | Test Setup Photos | 2023-05-19 | PDF 1.1 MB |
| Test Photos Thread | Test Setup Photos | 2023-05-19 | PDF 1.1 MB |
| Test Photos ZB | Test Setup Photos | 2023-05-19 | PDF 1.3 MB |
| AFC DUT Test Harness Report | Test Report | 2026-06-12 | PDF 2.7 MB |
| Antenna Report | Test Report | 2026-06-12 | PDF 3.5 MB |
| Test Report WLAN 6G pt. 1 | Test Report | 2026-06-12 | PDF 4.7 MB |
| Test Report WLAN 6G pt. 2 | Test Report | 2026-06-12 | PDF 3.6 MB |
| Antenna Test Report | Test Report | 2023-05-19 | PDF 3.5 MB |
| MPE Test Report | RF Exposure Info | 2023-05-19 | PDF 573.5 KB |
| Test Report 2.4G pt1 | Test Report | 2023-05-19 | PDF 5.4 MB |
| Test Report 2.4G pt2 | Test Report | 2023-05-19 | PDF 4.9 MB |
| Test Report 5G pt1 | Test Report | 2023-05-19 | PDF 5.3 MB |
| Test Report 5G pt2 | Test Report | 2023-05-19 | PDF 5.6 MB |
| Test Report 6G pt1 | Test Report | 2023-05-19 | PDF 5.4 MB |
| Test Report 6G pt2 | Test Report | 2023-05-19 | PDF 5.4 MB |
| Test Report 6G pt3 | Test Report | 2023-05-19 | PDF 3.8 MB |
| Test Report DFS | Test Report | 2023-05-19 | PDF 3.2 MB |
| Test Report LE | Test Report | 2023-05-19 | PDF 4.8 MB |
| Test Report Thread | Test Report | 2023-05-19 | PDF 3.9 MB |
| Test Report ZB | Test Report | 2023-05-19 | PDF 3.8 MB |
| Att Statement 2.911(d)(7) | Attestation Statements | 2026-06-12 | PDF 113.3 KB |
| Att Statements 2.911(d)(5)(i)&(ii) | Attestation Statements | 2026-06-12 | PDF 195.1 KB |
| Attestation 6SD | Attestation Statements | 2026-06-12 | PDF 114.8 KB |
| Attestation pt 2.911(5)(d)(i)&(ii) | Attestation Statements | 2023-05-19 | PDF 359.1 KB |
| Attestation pt 2.911(d)(5)(i)&(ii) | Attestation Statements | 2023-05-19 | PDF 359.1 KB |
| Attestation pt 2.911(d)(7) | Attestation Statements | 2023-05-19 | PDF 357.8 KB |
| Change letter for 6SD | Cover Letter(s) | 2026-06-12 | PDF 113.9 KB |
| Confidentiality Letter | Cover Letter(s) | 2026-06-12 | PDF 115.5 KB |
| LOA | Cover Letter(s) | 2026-06-12 | PDF 281 KB |
| Confidentiality Request | Cover Letter(s) | 2023-05-19 | PDF 361.4 KB |
| Declaration of Conformity | Cover Letter(s) | 2023-05-19 | PDF 303.2 KB |
| Declaration on LPI Operation | Cover Letter(s) | 2023-05-19 | PDF 306 KB |
| LOA | Cover Letter(s) | 2023-05-19 | PDF 363.7 KB |
| RF Exposure MPE | RF Exposure Info | 2026-06-12 | PDF 517 KB |
| Block Diagram Metadata only | Block Diagram | PDF 1.2 MB | |
| Schematics Metadata only | Schematics | PDF 2.3 MB | |
| OpDes Justification Report GPS NDA Metadata only | Operational Description | PDF 4.7 MB | |
| OpDes Justification Report Non-GPS NDA Metadata only | Operational Description | PDF 5.8 MB | |
| OpDes PIA Acceptane Letter GPS NDA Metadata only | Operational Description | PDF 224 KB | |
| OpDes PIA Acceptane Letter Non-GPS NDA Metadata only | Operational Description | PDF 227.2 KB | |
| OpDes PIA Inquiry GPS NDA Metadata only | Operational Description | PDF 508.7 KB | |
| OpDes PIA Inquiry Non-GPS NDA Metadata only | Operational Description | PDF 797.9 KB | |
| Operational Description Metadata only | Operational Description | PDF 1.3 MB | |
| Operational Description - SW Security Metadata only | SDR Software/Security Inf | PDF 727.2 KB | |
| OpDes Software Security Metadata only | SDR Software/Security Info. | PDF 727.2 KB |
Application Information
| Application ID | ABH5dsSEaqb5Me2bMfZ8sg== |
|---|---|
| Final Action Date | 2026-06-12 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0025216375 |
| Model | AP24 |
| Frequency Range | 6535-6855 MHz |
| Equipment Class | 6SD - 15E 6 GHz Standard Power Access Point |
| Device Description | 802.11ax 6E 2+2+2 Wireless Access Point |
| Responsible Party | Josh Rosenthal, jrosenthal@juniper.net |
| Non-Technical Contact | Josh Rosenthal, Juniper Networks, Inc, joshua.rosenthal@hpe.com |
| Test Firm | Alex Chen, Sporton International Inc. Hsinhua Laboratory, alex@sporton.com.tw |
| TCB Email | cb@industrial-ia.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| ABH5dsSEaqb5Me2bMfZ8sg== | 2026-06-12 | Original Equipment |
| PJRDPQI6eWxbwZnnFvLyEw== | 2023-05-19 | Original Equipment |
| HlAjhnuz3gOBfP8NKbIcPQ== | 2023-05-19 | Original Equipment |
| Bq3qUXWTG0L/MQ+gHpRkCQ== | 2023-05-19 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application PJRDPQI6eWxbwZnnFvLyEw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 05/19/2023 Application Dated: 05/05/2023 |
| Juniper Networks, Inc. |
| 1133 Innovation Way |
| Sunnyvale, CA 94089 |
| Attention: Josh Rosenthal , Hardware Engineering Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AHBN-AP24 |
| Name of Grantee: | Juniper Networks, Inc. |
| Equipment Class: | 15E 6 GHz Low Power Indoor Access Point |
| Notes: | 802.11ax WiFi6E 2+2+2 Indoor AP |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC EP MO | 15E | 5955.0 - 7095.0 | 0.6295 |
| Power listed is EIRP. Device operates with specific antennas in MIMO configurations as described in this filing. This device must be installed to provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes. Device is intended for indoor use only. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application PJRDPQI6eWxbwZnnFvLyEw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Juniper Networks, Inc. 1133 Innovation Way Sunnyvale, CA 94089 United States |
Date of Grant: 05/19/2023 Application Dated: 05/05/2023 |
| Attention: Josh Rosenthal , Hardware Engineering Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AHBN-AP24 |
| Name of Grantee: | Juniper Networks, Inc. |
| Equipment Class: | 15E 6 GHz Low Power Indoor Access Point |
| Notes: | 802.11ax WiFi6E 2+2+2 Indoor AP |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC EP MO | 15E | 5955.0 - 7095.0 | 0.6295 |
| Power listed is EIRP. Device operates with specific antennas in MIMO configurations as described in this filing. This device must be installed to provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes. Device is intended for indoor use only. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 05/19/2023 Application Dated: 05/05/2023 |
| Juniper Networks, Inc. |
| 1133 Innovation Way |
| Sunnyvale, CA 94089 |
| Attention: Josh Rosenthal , Hardware Engineering Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AHBN-AP24 |
| Name of Grantee: | Juniper Networks, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 802.11ax WiFi6E 2+2+2 Indoor AP |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.2291 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.2208 | ||
| CC MO ND | 15E | 5500.0 - 5720.0 | 0.2138 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.2153 |
| Output Power listed is the maximum combined conducted output power. This device must be installed to provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. This device supports 20, 40 and 80 MHz bandwidth modes. Device is intended for indoor use only. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application HlAjhnuz3gOBfP8NKbIcPQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Juniper Networks, Inc. 1133 Innovation Way Sunnyvale, CA 94089 United States |
Date of Grant: 05/19/2023 Application Dated: 05/05/2023 |
| Attention: Josh Rosenthal , Hardware Engineering Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AHBN-AP24 |
| Name of Grantee: | Juniper Networks, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 802.11ax WiFi6E 2+2+2 Indoor AP |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.2291 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.2208 | ||
| CC MO ND | 15E | 5500.0 - 5720.0 | 0.2138 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.2153 |
| Output Power listed is the maximum combined conducted output power. This device must be installed to provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. This device supports 20, 40 and 80 MHz bandwidth modes. Device is intended for indoor use only. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 05/19/2023 Application Dated: 05/05/2023 |
| Juniper Networks, Inc. |
| 1133 Innovation Way |
| Sunnyvale, CA 94089 |
| Attention: Josh Rosenthal , Hardware Engineering Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AHBN-AP24 |
| Name of Grantee: | Juniper Networks, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | 802.11ax WiFi6E 2+2+2 Indoor AP |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2402.0 - 2480.0 | 0.003 | ||
| CC MO | 15C | 2405.0 - 2475.0 | 0.0049 | ||
| CC MO | 15C | 2405.0 - 2475.0 | 0.0062 | ||
| CC MO | 15C | 2412.0 - 2462.0 | 0.2065 |
| Output Power listed is the maximum combined conducted output power. This device must be installed to provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. This device supports 20 and 40 MHz bandwidth modes. Device is intended for indoor use only. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application Bq3qUXWTG0L/MQ+gHpRkCQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Juniper Networks, Inc. 1133 Innovation Way Sunnyvale, CA 94089 United States |
Date of Grant: 05/19/2023 Application Dated: 05/05/2023 |
| Attention: Josh Rosenthal , Hardware Engineering Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AHBN-AP24 |
| Name of Grantee: | Juniper Networks, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | 802.11ax WiFi6E 2+2+2 Indoor AP |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2402.0 - 2480.0 | 0.003 | ||
| CC MO | 15C | 2405.0 - 2475.0 | 0.0049 | ||
| CC MO | 15C | 2405.0 - 2475.0 | 0.0062 | ||
| CC MO | 15C | 2412.0 - 2462.0 | 0.2065 |
| Output Power listed is the maximum combined conducted output power. This device must be installed to provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. This device supports 20 and 40 MHz bandwidth modes. Device is intended for indoor use only. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
IIA Lab Services, LLC 13146 NW 86th Drive Suite 400 Alachua, FL 32615 |
Date of Grant: 06/12/2026 Application Dated: 06/10/2026 |
| Juniper Networks, Inc. |
| 1133 Innovation Way |
| Sunnyvale, CA 94089 |
| Attention: Josh Rosenthal , Hardware Engineering Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AHBN-AP24 |
| Name of Grantee: | Juniper Networks, Inc. |
| Equipment Class: | 15E 6 GHz Standard Power Access Point |
| Notes: | 802.11ax 6E 2+2+2 Wireless Access Point |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BX CC EP MO | 15E | 5955.0 - 6415.0 | 1.1695 | ||
| BX CC EP MO | 15E | 6535.0 - 6855.0 | 1.2106 |
| Power listed is EIRP. Professional installation required. Device operates with specific antennas in MIMO configurations as described in this filing. This device must be installed to provide a separation distance of at least 26 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes. Device is intended for indoor use only. |
| BX: | This standard power access point is authorized as a composite under 47 CFR 15.407(a)(4) and an indoor access point under 47 CFR 15.407(a)(5), allowing the AFCs that are issued waiver FCC 24-1217 to consider up to 6 dB of building entry loss (BEL). |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |