NIP3A Remote Key Test Report 1 Kaba Ilco Corp

Kaba Ilco Corp Remote Key

Page 1 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 2 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 3 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 4 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 5 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 6 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 7 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 8 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 9 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 10 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 11 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 12 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 13 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 14 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 15 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 16 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 17 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 18 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 19 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 20 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 21 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 22 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 23 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 24 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 25 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 26 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 27 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 28 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 29 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Page 30 of NIP3A Remote Key Test Report 1 Kaba Ilco Corp

FCC TEST REPORT
FCC ID: 2AHH9-NIP3A
On Behalf of
Kaba Ilco Corp
Remote Key
Model No.: PRX-NIS-5B3
Prepared for
Address
: Kaba Ilco Corp
: 400 Jeffreys Road, Rocky Mount, NC 27804, United States
Prepared By
: Shenzhen Alpha Product Testing Co., Ltd.
Building i, No.2, Lixin Road, Fuyong Street, Bao’an District, 518103,
Shenzhen, Guangdong, China
Address
Report Number
Date of Receipt
Date of Test
Date of Report
Version Number
T1881860 01
December 1, 2018
December 1-12, 2018
December 12, 2018
REV0
Page 2 of 30
Report No.: T1881860 01
Contents
1.
General Information ............................................................................................................... 5
1.1.
1.2.
1.3.
1.4.
2.
Summary of test ...................................................................................................................... 7
2.1.
2.2.
2.3.
2.4.
2.5.
2.6.
3.
Test limit.............................................................................................................19
Method of measurement .....................................................................................19
Test Setup ...........................................................................................................19
Test Results ........................................................................................................19
Transmission time ................................................................................................................. 21
6.1.
6.2.
6.3.
6.4.
7.
Conducted Emission Limits (15.209) ................................................................17
Test Setup ...........................................................................................................17
Test Procedure ....................................................................................................18
Test Results ........................................................................................................18
Occupied bandwidth ............................................................................................................. 19
5.1.
5.2.
5.3.
5.4.
6.
Radiation Emission Limits(15.209&231) ..........................................................10
Test Setup ...........................................................................................................10
Test Procedure ....................................................................................................12
Test Equipment Setting For emission test. .........................................................12
Test Condition ....................................................................................................12
Test Result ..........................................................................................................12
POWER LINE CONDUCTED EMISSION ....................................................................... 17
4.1.
4.2.
4.3.
4.4.
5.
Summary of test result .........................................................................................7
Block Diagram .....................................................................................................8
Test mode .............................................................................................................8
Test Conditions.....................................................................................................8
Measurement Uncertainty (95% confidence levels, k=2) ....................................8
Test Equipment.....................................................................................................9
Radiation Emission ............................................................................................................... 10
3.1.
3.2.
3.3.
3.4.
3.5.
3.6.
4.
Description of Device (EUT) ...............................................................................5
Accessories of Device (EUT)...............................................................................6
Tested Supporting System Details .......................................................................6
Test Facility ..........................................................................................................6
Test limit.............................................................................................................21
Method of measurement .....................................................................................21
Test Setup ...........................................................................................................21
Test Results ........................................................................................................22
Antenna Requirement .......................................................................................................... 23
7.1. Standard Requirement ........................................................................................23
7.2. Antenna Connected Construction ......................................................................23
7.3. Result..................................................................................................................23
8.
9.
Test setup photo .................................................................................................................... 24
Photos of EUT ....................................................................................................................... 25
Page 3 of 30
Report No.: T1881860 01
TEST REPORT DECLARATION
Applicant
Kaba Ilco Corp
Address
400 Jeffreys Road, Rocky Mount, NC 27804, United States
Manufacturer
Qinuo Electronics Co., Ltd
Address
3/F, Bldg.A, Yucheng Base, Keji Rd., High-tech Industrial Park, Fengze, Quanzhou,
Fujian 362000, P.R. China
EUT Description
Remote Key
(A)
Model No.
PRX-NIS-5B3
(B)
Trademark
N/A
Measurement Standard Used:
FCC Rules and Regulations Part 15 Subpart C Section 15.231: 2017
ANSI C63.10-2013
The device described above is tested by Shenzhen Alpha Product Testing Co., Ltd. to determine the maximum
emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 15
Subpart C limits both conducted and radiated emissions. The test results are contained in this test report and
Shenzhen Alpha Product Testing Co., Ltd. is assumed of full responsibility for the accuracy and completeness
of these tests.
After the test, our opinion is that EUT compliance with the requirement of the above standards.
This report applies to above tested sample only. This report shall not be reproduced in parts without written
approval of Shenzhen Alpha Product Testing Co., Ltd.
Tested by (name + signature)........…..:
Reak Yang
………………………………….
Project Engineer
Approved by (name + signature)…....:
Simple Guan
Project Manager
Date of issue…… …………………..:
December 12, 2018
………………………………….
Page 4 of 30
Report No.: T1881860 01
Revision History
Revision
Issue Date
Revisions
00
December 12, 2018
Initial released Issue
Revised By
Simple Guan
Page 5 of 30
1. General Information
1.1. Description of Device (EUT)
EUT
: Remote Key
Model No.
DIFF.
: PRX-NIS-5B3
: N/A
Trade mark
: N/A
Power supply
: DC 3V by button cell
Operation frequency : 433.92MHz
Modulation
: FSK
Antenna Type
: Internal Antenna, Maximum Gain is 0dBi
Software version
Hardware version
: V1.0
: V1.0
Report No.: T1881860 01
Page 6 of 30
Report No.: T1881860 01
1.2. Accessories of Device (EUT)
Accessories1
Manufacturer
Model
Power supply
1.3. Tested Supporting System Details
No.
Description
Manufacturer
Model
Serial Number
1.4. Test Facility
Shenzhen Alpha Product Testing Co., Ltd
Building i, No.2, Lixin Road, Fuyong Street, Bao’an District, 518103,
Shenzhen, Guangdong, China
June 21, 2018 File on Federal Communication Commission
Registration Number: 293961
July 25, 2017 Certificated by IC
Registration Number: 12135A
Certification or
DOC
Page 7 of 30
Report No.: T1881860 01
2. Summary of test
2.1. Summary of test result
Description of Test Item
Standard
Results
Spurious Emission
Section 15.231&15.209
PASS
Conduction Emission
Section 15.207
N/A
Occupied bandwidth
Section 15.231
PASS
Transmission time
Section 15.231
PASS
Band Edge
Section 15.231
N/A
Antenna Requirement
Section 15.203
PASS
Note :Test according to ANSI C63.10-2013
Page 8 of 30
Report No.: T1881860 01
2.2. Block Diagram
1. For radiated emissions test: EUT was placed on a turn table, which is 0.8 meters
high above ground for below 1 GHz test and 1.5 meters high above ground for
below 1 GHz test . EUT was set into test mode before test. New battery is used
during all test
EUT
2.3. Test mode
EUT work in Continuous TX mode, and select test channel, wireless mode
Tested mode, channel, and data rate information
Mode
Channel
Frequency
(MHz)
FSK
CH1
433.92
2.4. Test Conditions
Temperature range
21-25℃
Humidity range
40-75%
Pressure range
86-106kPa
2.5. Measurement Uncertainty (95% confidence levels, k=2)
Item
Uncertainty
Uncertainty for Power point Conducted Emissions Test
2.74dB
Uncertainty for Radiation Emission test in 3m chamber
(below 30MHz)
2.13 dB(Polarize: V)
Uncertainty for Radiation Emission test in 3m chamber
(30MHz to 1GHz)
Uncertainty for Radiation Emission test in 3m chamber
(1GHz to 25GHz)
Uncertainty for radio frequency
Uncertainty for conducted RF Power
Uncertainty for temperature
Uncertainty for humidity
Uncertainty for DC and low frequency voltages
3.77dB(Polarize: V)
3.80dB(Polarize: H)
4.16dB(Polarize: H)
4.13dB(Polarize: V)
5.4×10-8
0.37dB
0.2℃
1%
0.06%
2.57dB(Polarize: H)
Page 9 of 30
Report No.: T1881860 01
2.6. Test Equipment
Equipment
Manufacture
Model No.
Serial No.
Last cal.
Cal Interval
3m
Semi-Anechoic
ETS-LINDGRE
N/A
SEL0017
2018.09.21
1Year
Spectrum analyzer
Agilent
E4407B
MY46185649
2018.09.21
1Year
Receiver
R&S
ESCI
1166.5950K03-1011
2018.09.21
1Year
Receiver
R&S
ESCI
101202
2018.09.21
1Year
Bilog Antenna
Schwarzbeck
VULB 9168
VULB9168-438
2018.04.13
2Year
Horn Antenna
EMCO
3115
640201028-06
2018.04.13
2Year
Active Loop
Antenna
Beijing Daze
ZN30900A
SEL0097
2018.04.13
2Year
Cable
Resenberger
N/A
No.1
2018.09.21
1Year
Cable
SCHWARZBEC
N/A
No.2
2018.09.21
1Year
Cable
SCHWARZBEC
N/A
No.3
2018.09.21
1Year
Pre-amplifier
Schwarzbeck
BBV9743
9743-019
2018.09.21
1Year
Pre-amplifier
R&S
AFS33-1800265030-8P-44
SEL0080
2018.09.21
1Year
Temperature
controller
Terchy
MHQ
120
2018.09.21
1Year
20db Attenuator
ICPROBING
IATS1
82347
2018.09.21
1 Year
BBHA 9170
BBHA 9170294
2018.04.13
2 Year
ML2487A
6K00001491
2018.09.21
1 Year
SCHWARZBEC
Horn Antenna
Power Meter
Anritsu
Page 10 of 30
Report No.: T1881860 01
3. Radiation Emission
3.1. Radiation Emission Limits(15.209&231)
Frequency
(MHz)
0.009-0.490
Field Strength
Limits at 3 metres (watts, e.i.r.p.)
uV/m
dB uV/m
Measurement
distance(m)
2400/F(kHz)
XX
300
0.490-1.705
24000/F(kHz)
XX
30
1.705-30
30
29.5
30
30~88
100(3nW)
40
88~216
150(6.8nW)
43.5
216~960
200(12nW)
46
Above960
500(75nW)
54
75.6(AV)
95.6(PK)
Carrier
frequency
Carrier
frequency
NOTE:
a) The tighter limit applies at the band edges.
b) Emission Level(dB uV/m)=20log Emission Level(Uv/m)
3.2. Test Setup
See the next page.
Page 11 of 30
Below 30MHz Test Setup
Above 30MHz Test Setup
Report No.: T1881860 01
Page 12 of 30
Report No.: T1881860 01
Above 1GHz Test Setup
3.3. Test Procedure
a) The measureing distance of 3m shall be used for measurements at frequency up to
1GHz and above 1GHz, The EUT was placed on a rotating 0.8 m high above
ground,The table was rotated 360 degrees to determine the position of the highest
radiation
b) The Test antenna shall vary between 1m and 4m,Both Horizontal and Vertical
antenna are set ot make measurement.
c) The initial step in collecting conducted emission data is a spectrum analyzer Peak
detector mode pre-scanning the measurement frequency range. Significent Peaks are
then marked. and then Qusia Peak Detector mode remeasured
d) If Peak value comply with QP limit Below 1GHz.The EUT deemed to comply with
QP limit. But the Peak value and average value both need to comply with applicable
limit above 1GHz.
e) For the actual test configuration, please see the test setup photo.
3.4. Test Equipment Setting For emission test.
9KHz~150KHz
150KHz~30MHz
30MHz~1GHz
Above 1GHz
RBW 200Hz
RBW 9KHz
RBW 120KHz
RBW 1MHz
VBW1KHz
VBW 30KHz
VBW 300KHz
VBW 3MHz
3.5. Test Condition
Continual Transmitting in maximum power(The new battery be used during Test)
3.6. Test Result
We have scanned the 10th harmonic from 9KHz to the EUT.
Detailed information please see the following page.
From 9KHz to 30MHz: Conclusion: PASS
Note: The amplitude of spurious emissions which are
attenuated by more than 20dB below the permissible value has
no need to be reported.
Page 13 of 30
Report No.: T1881860 01
Notes: 1 --Means other frequency and mode comply with standard requirements and at
least have 20dB margin.
Correct Factor=Cable Loss+Antenna Factor-Amplifier Gain
Measurement Result=Reading + Correct Factor
Margin=Measurement Result-Limit
2 –Spectrum setting:
a. Peak setting 30MHz-1GHz, RBW=100KHz, VBW=300KHz.
3- PK measure result values is less than the AVG limit values, so AV measure
result values test not applicable.
Page 14 of 30
Report No.: T1881860 01
Radiated Emissions Result of Inside band
EUT
Remote Key
Model Name
PRX-NIS-5B3
Temperature
25oC
Relative Humidity
56%
Pressure
960hPa
Test voltage
DC 3V by button cell
Test Mode
TX 433.92MHz
Test by
Reak
Channel (433.92MHz Below 1GHz)
Polarization: Horizontal
No.
Frequency
(MHz)
Reading
(dBuV)
Factor (dB)
Results
(dBuV/m)
Limit
Margin
Detector
(dBuV/m) (dB)
433.92
55.08
16.37
72.17
100.82
-28.65
PK
433.92
80.82
AV
Remark:
1. All readings are Quasi-Peak and Average values.
2. Margin = Result (Result =Reading + Factor )–Limi
3. When peak value applied to AVG limit, the AVG value is not calculated.
Page 15 of 30
Report No.: T1881860 01
Channel (433.92MHz Below 1GHz)
Polarization: Vertical
No.
Frequency
(MHz)
Reading
(dBuV)
Factor (dB)
Results
(dBuV/m)
Limit
Margin
Detector
(dBuV/m) (dB)
433.92
57.53
16.37
73.90
100.82
-26.92
PK
433.92
80.82
AV
Remark:
1. All readings are Quasi-Peak and Average values.
2. Margin = Result (Result =Reading + Factor )–Limi
3. When peak value applied to AVG limit, the AVG value is not calculated.
Page 16 of 30
Channel (433.92MHz Above 1GHz)
Polarization: Horizontal
Channel (433.92MHz Above 1GHz)
Polarization: Vertical
Report No.: T1881860 01
Page 17 of 30
Report No.: T1881860 01
4. POWER LINE CONDUCTED EMISSION
4.1.
Conducted Emission Limits (15.209)
Limits dB(μV)
Frequency
MHz
0.15 -0.50
0.50 -5.00
5.00 -30.00
Quasi-peak Level
Average Level
66 -56*
56
60
56 - 46*
46
50
Notes: 1. *Decreasing linearly with logarithm of frequency.
2. The lower limit shall apply at the transition frequencies.
3.The limit decreases in line with the logarithm of the frequency in the rang of
0.15 to 0.50 MHz.
4.2.
Test Setup
Page 18 of 30
Report No.: T1881860 01
4.3. Test Procedure
The EUT is put on the plane 0.8m high above the ground by insulating support
and is connected to the power mains through a line impedance stabilization
network (L.I.S.N.). This provides a 50ohm coupling impedance for the EUT
system. Please refer the block diagram of the test setup and photographs. Both
sides of AC lines are checked to find out the maximum conducted emission. In
order to find the maximum emission levels, the relative positions of equipment
and all of the interface cables shall be changed according to ANSI C63.10:2013
on Conducted Emission Measurement.
The bandwidth of test receiver (R & S ESCI) is set at 9 kHz.
4.4. Test Results
EUT power supply by battery, so the test not applicable.
Page 19 of 30
Report No.: T1881860 01
5. Occupied bandwidth
5.1. Test limit
Please refer section RSS-210 & 15.231
According to§15.231(C), The bandwidth of the emission shall be no wider than 0.25%
of the center frequency for devices operating above 70MHz and below 900MHz.
5.2. Method of measurement
a)The bandwidth is measured at an amplitude level reduced 20dB from the reference
level. The reference level is the level of the highest amplitude signal observed
from the transmitter at the fundamental frequency. Once the reference level is
established, the equipment is conditioned with typical modulating signal to
produce the worst-case (i.e. the widest) bandwidth.
b)The test receiver RBW set 30KHz,VBW set 30KHz,Sweep time set auto.
5.3. Test Setup
Spectrum
Analyzer
EUT
5.4. Test Results
Mode
Freq
(MHz)
20dB Bandwidth
(KHz)
186.3
FSK
433.92
Note: Limit = 433.92MHz *0.25% = 1084.8 kHz
99%
Bandwidth
Limit
(kHz)
Conclusion
170.28
1084.8
PASS
Page 20 of 30
433.92MHz
Report No.: T1881860 01
Page 21 of 30
Report No.: T1881860 01
6. Transmission time
6.1. Test limit
Please refer sectionRSS-210 & 15.231
According to §15.231(a)(1), A manually operated transmitter shall employ a switch that will
automatically deactivate the transmitter within not more than 5 seconds of being released.
6.2. Method of measurement
6.2.1. Place the EUT on the table and set it in transmitting mode.
6.2.2. Remove the antenna from the EUT and then connect a low loss RF cable from the
antenna port to the spectrum analyzer.
6.2.3. Set spectrum analyzer Center= 433.92MHz, Span = 0MHz, Sweep = 5s.
6.2.4. Set the spectrum analyzer as RBW, VBW=1MHz,
6.2.5. Max hold, view and count how many channel in the band.
6.3. Test Setup
EUT
Spectrum
Analyzer
Page 22 of 30
Report No.: T1881860 01
6.4. Test Results
Freq
(MHz)
Test Result(s)
Limit (s)
Conclusion
433.92
0.420
< 5s
PASS
Compliance with 15.231 a(1) section.
Page 23 of 30
Report No.: T1881860 01
7. Antenna Requirement
7.1. Standard Requirement
An intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a
permanently attached antenna or of an antenna that uses a unique coupling to the
intentional radiator shall be considered sufficient to comply with the provisions of
this Section. The manufacturer may design the unit so that a broken antenna can
be replaced by the user, but the use of a standard antenna jack or electrical
connector is prohibited.
7.2. Antenna Connected Construction
The directional gains of antenna used for transmitting is 0 dBi, and the antenna
connector is de- signed with permanent attachment and no consideration of
replacement. Please see EUT photo for details.
7.3. Result
The EUT antenna is Internal antenna. It comply with the standard requirement.
Page 24 of 30
8. Test setup photo
Photos of Radiated emission
Report No.: T1881860 01
Page 25 of 30
9. Photos of EUT
Report No.: T1881860 01
Page 26 of 30
Report No.: T1881860 01
Page 27 of 30
Report No.: T1881860 01
Page 28 of 30
Report No.: T1881860 01
Page 29 of 30
Report No.: T1881860 01
Page 30 of 30
---------END OF THE REPORT-------
Report No.: T1881860 01
Download: NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Mirror Download [FCC.gov]NIP3A Remote Key Test Report 1 Kaba Ilco Corp
Document ID4120825
Application IDTm+11X70ilfsqLVcqtmI7Q==
Document Descriptiontest report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize131.64kB (1645446 bits)
Date Submitted2018-12-28 00:00:00
Date Available2018-12-28 00:00:00
Creation Date2018-12-25 07:50:51
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2018-12-28 18:21:00
Document TitleTest Report 1
Document CreatorMicrosoft® Office Word 2007
Document Author: Yu

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Has XFA                         : No
Language                        : zh-CN
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Format                          : application/pdf
Creator                         : Yu
Title                           : 1
Create Date                     : 2018:12:25 07:50:51
Creator Tool                    : Microsoft® Office Word 2007
Modify Date                     : 2018:12:28 18:21+08:00
Metadata Date                   : 2018:12:28 18:21+08:00
Producer                        : Microsoft® Office Word 2007
Document ID                     : uuid:6c5350b0-2b2a-495c-9187-5b2d6c4ad0af
Instance ID                     : uuid:3703e5b5-53df-4734-aed3-bfe500a1cd55
Page Count                      : 30
Author                          : Yu