FCC ID 2AHJLR5

Walkie Talkie

by Shenzhen Freetalker Industry Co., Ltd

Grantee Code: 2AHJL   Product Code: R5
Latest application date: 2019-08-22

FCC ID Device Details

FCC ID2AHJLR5
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AHJL
Product CodeR5
Applicant BusinessShenzhen Freetalker Industry Co., Ltd 🇨🇳
Equipment ClassWalkie Talkie
Test FirmMRT Technology (Suzhou) Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
462.55-462.725 MHzOriginal Equipment2019-08-22

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2019-08-22PDF 560.3 KB
internal photosInternal Photos2019-08-22PDF 1.6 MB
external photosExternal Photos2019-08-22PDF 551.8 KB
labelID Label/Location Info2019-08-22PDF 2.9 MB
label location statementCover Letter(s)2019-08-22PDF 189.5 KB
test setup photosTest Setup Photos2019-08-22PDF 2.8 MB
SAR test reportRF Exposure Info2019-08-22PDF 2.3 MB
equipment calibration report SARTest Report2019-08-22PDF 5.5 MB
test reportTest Report2019-08-22PDF 2 MB
15B attestation letterAttestation Statements2019-08-22PDF 13.2 KB
POACover Letter(s)2019-08-22PDF 61.9 KB
confidentiality request letterCover Letter(s)2019-08-22PDF 130 KB
model declaration letterCover Letter(s)2019-08-22PDF 54.1 KB
block diagram Metadata onlyBlock DiagramPDF 36.9 KB
schematics Metadata onlySchematicsPDF 233.6 KB
antenna spec. operation description Metadata onlyOperational DescriptionPDF 91 KB
operation description Metadata onlyOperational DescriptionPDF 247.4 KB
part list Metadata onlyParts List/Tune Up InfoPDF 58.5 KB
tune up procedure Metadata onlyParts List/Tune Up InfoPDF 14.3 KB

Application Information

Application IDj4p7TyE3rPXCsMBmwehTlw==
Final Action Date2019-08-22
Application PurposeOriginal Equipment
Applicant FRN0025343542
ModelR5
Frequency Range462.55-462.725 MHz
Equipment ClassFRF - Part 95 Family Radio Face Held Transmitter
Device DescriptionWalkie Talkie
Responsible PartyJianqiang Yang, jqyang@163.com , +86 0755 83121380
Test FirmMr. Marlin Chen, MRT Technology (Suzhou) Co., Ltd., marlinchen@mrt-cert.com , +86-512-66308358
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is ERP. This device is authorized to operate in FRS (Part 95B) radio service. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Hand held and body-worn SAR compliance is limited to the specific belt-clips, holsters and accessories tested for this device. Users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported 50% duty cycle SAR levels for head and body-worn accessories exposure conditions are 0.26 W/kg and 0.30 W/kg respectively.

Applications

Application IDDatePurpose
j4p7TyE3rPXCsMBmwehTlw==2019-08-22Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
462.55-462.725 MHz0.11090.12ppm10K0F3E95B
462.563-462.713 MHz0.12710.11ppm10K0F3E95B
467.563-467.713 MHz0.08550.11ppm10K0F3E95B

Grants

TCB Grant - Application j4p7TyE3rPXCsMBmwehTlw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 08/22/2019

Application Dated: 08/22/2019
Shenzhen Freetalker Industry Co., Ltd
6/F, Building A, Xinghong Science Park, No.111 of
Shuiku Rd., Fenghuanggang, Xixiang, Bao'an,
Shenzhen,
China
 
Attention: Jianqiang Yang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AHJLR5
Name of Grantee:  Shenzhen Freetalker Industry Co., Ltd
Equipment Class: Part 95 Family Radio Face Held Transmitter
Notes: Walkie Talkie
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
95B 462.5625  -  462.7125 0.1271 0.11  PM 10K0F3E
95B 467.5625  -  467.7125 0.0855 0.11  PM 10K0F3E
95B 462.55  -  462.725 0.1109 0.12  PM 10K0F3E

Output power listed is ERP. This device is authorized to operate in FRS (Part 95B) radio service. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Hand held and body-worn SAR compliance is limited to the specific belt-clips, holsters and accessories tested for this device. Users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported 50% duty cycle SAR levels for head and body-worn accessories exposure conditions are 0.26 W/kg and 0.30 W/kg respectively.

EAS Grant - Application j4p7TyE3rPXCsMBmwehTlw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Freetalker Industry Co., Ltd
6/F, Building A, Xinghong Science Park, No.111 of Shuiku Rd., Fenghuanggang, Xixiang, Bao'an,
Shenzhen,
China
  Date of Grant: 08/22/2019

Application Dated: 08/22/2019
 
Attention: Jianqiang Yang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AHJLR5
Name of Grantee:  Shenzhen Freetalker Industry Co., Ltd
Equipment Class: Part 95 Family Radio Face Held Transmitter
Notes: Walkie Talkie
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
95B 462.5625  -  462.7125 0.1271 0.11  PM 10K0F3E
95B 467.5625  -  467.7125 0.0855 0.11  PM 10K0F3E
95B 462.55  -  462.725 0.1109 0.12  PM 10K0F3E

Output power listed is ERP. This device is authorized to operate in FRS (Part 95B) radio service. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Hand held and body-worn SAR compliance is limited to the specific belt-clips, holsters and accessories tested for this device. Users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported 50% duty cycle SAR levels for head and body-worn accessories exposure conditions are 0.26 W/kg and 0.30 W/kg respectively.



Mail To: