FCC ID 2AHLE-BGMG002
Blood Glucose Monitoring System
by Bioland Technology Ltd.
Grantee Code: 2AHLE Product Code: BGMG002
Latest application date: 2016-09-28
FCC ID Device Details
| FCC ID | 2AHLE-BGMG002 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AHLE |
| Product Code | BGMG002 |
| Applicant Business | Bioland Technology Ltd. 🇨🇳 |
| Related Domains | |
| Equipment Class | Blood Glucose Monitoring System |
| Test Firm | SGS-CSTC Standards Technical Services Co.,Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.2-848.8 MHz | Original Equipment | 2016-09-28 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| G-427G user manual | Users Manual | 2016-09-28 | PDF 605.7 KB |
| Internal Photos -rev | Internal Photos | 2016-09-28 | PDF 664.3 KB |
| External Photos | External Photos | 2016-09-28 | PDF 449.7 KB |
| G-427G label | ID Label/Location Info | 2016-09-28 | PDF 141.9 KB |
| setup photos-rev | Test Setup Photos | 2016-09-28 | PDF 737.9 KB |
| Appendix B - Test Report for SZEM160200075301-rev | Test Report | 2016-09-28 | PDF 1.3 MB |
| SZEM160200075301-rev | Test Report | 2016-09-28 | PDF 3.9 MB |
| Authority to Act as Agent | Cover Letter(s) | 2016-09-28 | PDF 43.6 KB |
| Model confirmation letter | Cover Letter(s) | 2016-09-28 | PDF 26.2 KB |
| Request for confidentiality-rev | Cover Letter(s) | 2016-09-28 | PDF 66 KB |
| SZEM160200075302-SAR-rev | RF Exposure Info | 2016-09-28 | PDF 5.2 MB |
| Confidential_G-427G Block Diagram Metadata only | Block Diagram | PDF 249.2 KB | |
| Confidential_RF module Block diagram Metadata only | Block Diagram | PDF 247.5 KB | |
| Confidential_G-427G Circuit Diagram Metadata only | Schematics | PDF 139.7 KB | |
| Confidential_RF module circuit diagram Metadata only | Schematics | PDF 1.7 MB | |
| Confidential_G-427G Operation Description-rev 2 Metadata only | Operational Description | PDF 100.4 KB | |
| Confidential_G-427G Operation Description-rev 3 Metadata only | Operational Description | PDF 132.6 KB | |
| Tune up procedure-rev Metadata only | Parts List/Tune Up Info | PDF 24.4 KB |
Application Information
| Application ID | ui43NL8Ky5v8n3/ph4R8AA== |
|---|---|
| Final Action Date | 2016-09-28 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0025357419 |
| Model | BGMG002 |
| Frequency Range | 824.2-848.8 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Blood Glucose Monitoring System |
| Responsible Party | Qilian Liu, regulator@bioland.com.cn |
| Agent | Sade Sade Sade, SGS-CSTC Standards Technical ServicesLtd, Sade.Luo@sgs.com |
| Technical Contact | Keny Xu, SGS-CSTC Standards Technical Services Co., Ltd, keny.xu@sgs.com |
| Non-Technical Contact | Sade Luo, SGS-CSTC Standards Technical Services Co., Ltd, Sade.Luo@sgs.com |
| Test Firm | June Zhang, SGS-CSTC Standards Technical Services Co.,Ltd., June.Zhang@sgs.com |
| TCB Email | hotline@acbcert.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output is ERP for Part 22 and EIRP for Part 24. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for body-worn accessory is 1.56 W/kg; This device contains GSM/GPRS functions that are not operational in U.S. Territories. This filing is only applicable for 850 MHz Cellular and 1900 MHz PCS operations. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| ui43NL8Ky5v8n3/ph4R8AA== | 2016-09-28 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application ui43NL8Ky5v8n3/ph4R8AA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 09/28/2016 Application Dated: 09/26/2016 |
| Bioland Technology Ltd. |
| A6b7 (Block G), Shangrong Ind. Zone |
| Baolong 5th Rd, Longgang District |
| Shenzhen guangdong, 518116 China |
| Attention: Qilian Liu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AHLE-BGMG002 |
| Name of Grantee: | Bioland Technology Ltd. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Blood Glucose Monitoring System |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22H | 824.2 - 848.8 | 2.2284 | 0.1 PM | 250KGXW |
| BC | 24E | 1850.2 - 1909.8 | 1.099 | 0.1 PM | 248KGXW |
| Power output is ERP for Part 22 and EIRP for Part 24. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for body-worn accessory is 1.56 W/kg; This device contains GSM/GPRS functions that are not operational in U.S. Territories. This filing is only applicable for 850 MHz Cellular and 1900 MHz PCS operations. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
EAS Grant - Application ui43NL8Ky5v8n3/ph4R8AA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Bioland Technology Ltd. A6b7 (Block G), Shangrong Ind. Zone Baolong 5th Rd, Longgang District Shenzhen guangdong, 518116 China |
Date of Grant: 09/28/2016 Application Dated: 09/26/2016 |
| Attention: Qilian Liu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AHLE-BGMG002 |
| Name of Grantee: | Bioland Technology Ltd. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Blood Glucose Monitoring System |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22H | 824.2 - 848.8 | 2.2284 | 0.1 PM | 250KGXW |
| BC | 24E | 1850.2 - 1909.8 | 1.099 | 0.1 PM | 248KGXW |
| Power output is ERP for Part 22 and EIRP for Part 24. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for body-worn accessory is 1.56 W/kg; This device contains GSM/GPRS functions that are not operational in U.S. Territories. This filing is only applicable for 850 MHz Cellular and 1900 MHz PCS operations. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
| Mail To: |