IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.

Dyaco International Inc. ENT CONSOLE

Page 1 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 2 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 3 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 4 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 5 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 6 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 7 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 8 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 9 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 10 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 11 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 12 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 13 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 14 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 15 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 16 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 17 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 18 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 19 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 20 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 21 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 22 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 23 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 24 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 25 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 26 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 27 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 28 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 29 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 30 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 31 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 32 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 33 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 34 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 35 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 36 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 37 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 38 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 39 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 40 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 41 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 42 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 43 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 44 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 45 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 46 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 47 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 48 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 49 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 50 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 51 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 52 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 53 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 54 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 55 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 56 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 57 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 58 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 59 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 60 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 61 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 62 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 63 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 64 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 65 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 66 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 67 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 68 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 69 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Page 70 of IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.

Page 1 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
FCC 15.247
2.4 GHz Report
for
Dyaco International Inc.
12F, No. 111, Songjiang Road,
Taipei, Taiwan
Product Name
Model Name
FCC ID
: ENT CONSOLE
: (1)WT002 (2)WB001
: 2AHVL-IEITB1DYACO
Prepared by:
: AUDIX Technology Corporation,
EMC Department
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 2 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
TABLE OF CONTENTS
Description
Page
TEST REPORT CERTIFICATION ............................................................................................. 4
1. REPORT HISTORY.............................................................................................................. 5
2. SUMMARY OF TEST RESULTS ....................................................................................... 6
3. GENERAL INFORMATION ............................................................................................... 7
3.1. Description of EUT .....................................................................................................................7
3.3. Antenna Information ..................................................................................................................8
3.4. EUT Specifications Assessed in Current Report......................................................................8
3.5. Test Configuration .................................................................................................................... 10
3.6. Tested Supporting System List ................................................................................................ 11
3.7. Setup Configuration ................................................................................................................. 11
3.8. Operating Condition of EUT ................................................................................................... 11
3.9. Description of Test Facility ...................................................................................................... 12
3.10. Measurement Uncertainty ....................................................................................................... 12
4. MEASUREMENT EQUIPMENT LIST ............................................................................ 13
4.1. Conducted Emission Measurement ......................................................................................... 13
4.2. Radiated Emission Measurement ............................................................................................ 13
4.3. RF Conducted Measurement ................................................................................................... 13
5. CONDUCTED EMISSION MEASUREMET ................................................................... 14
5.1.
5.2.
5.3.
5.4.
Block Diagram of Test Setup ................................................................................................... 14
Power Line Conducted Emission Limit .................................................................................. 14
Test Procedure .......................................................................................................................... 14
Conducted Emission Measurement Results ........................................................................... 15
6. RADIATED EMISSION MEASUREMENT .................................................................... 19
6.1.
6.2.
6.3.
6.4.
6.5.
Block Diagram of Test Setup ................................................................................................... 19
Radiated Emission Limits ........................................................................................................ 20
Test Procedure .......................................................................................................................... 21
Measurement Result Explanation ........................................................................................... 22
Test Results................................................................................................................................ 22
7. 20dB BANDWIDTH MEASUREMENT ........................................................................... 37
7.1.
7.2.
7.3.
7.4.
Block Diagram of Test Setup ................................................................................................... 37
Specification Limits .................................................................................................................. 37
Test Procedure .......................................................................................................................... 37
Test Results................................................................................................................................ 37
8. CARRIER FREQUENCY SEPARATION MEASUREMENT ...................................... 38
8.1.
8.2.
8.3.
8.4.
Block Diagram of Test Setup ................................................................................................... 38
Specification Limits .................................................................................................................. 38
Test Procedure .......................................................................................................................... 38
Test Results................................................................................................................................ 38
9. TIME OF OCCUPANCY MEASUREMENT................................................................... 39
9.1.
9.2.
9.3.
9.4.
Block Diagram of Test Setup ................................................................................................... 39
Specification Limits .................................................................................................................. 39
Test Procedure .......................................................................................................................... 39
Test Results................................................................................................................................ 39
10. NUMBER OF HOPPING CHANNELS MEASUREMENT ......................................... 40
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 3 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
10.1. Block Diagram of Test Setup ................................................................................................... 40
10.2. Specification Limits .................................................................................................................. 40
10.3. Test Procedure .......................................................................................................................... 40
10.4. Test Results................................................................................................................................ 40
11. MAXIMUM PEAK OUTPUT POWER MEASUREMENT ......................................... 41
11.1. Block Diagram of Test Setup ................................................................................................... 41
11.2. Specification Limits .................................................................................................................. 41
11.3. Test Procedure .......................................................................................................................... 41
11.4. Test Results................................................................................................................................ 41
12. EMISSION LIMITATIONS MEASUREMENT ............................................................ 42
12.1. Block Diagram of Test Setup ................................................................................................... 42
12.2. Specification Limits .................................................................................................................. 42
12.3. Test Procedure .......................................................................................................................... 42
12.4. Test Results................................................................................................................................ 42
13. DEVIATION TO TEST SPECIFICATIONS.................................................................. 43
APPENDIX A TEST PLOTS
APPENDIX B TEST PHOTOGRAPHS
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 4 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
TEST REPORT CERTIFICATION
Applicant
Manufacture
Product Name
Model No.
Serial No.
Power Supply
Dyaco International Inc.
Dyaco Canada Inc.
ENT CONSOLE
(1)WT002 (2)WB001
N/A
DC 12V
Applicable Standards:
47 CFR FCC Part 15 Subpart C: 2016
ANSI C63.10:2013
FCC Public Notice DA 00-705
AUDIX Technology Corp. tested the equipment mentioned in accordance with the
requirements set forth in the above standards. Test results indicate that the equipment tested is
capable of demonstrating compliance with the requirements as documented within this report.
AUDIX Technology Corp. does not assume responsibility for any conclusions and
generalizations drawn from the test results with regard to other specimens and samples.
Date of Test:
2016. 11. 02 ~ 21
Date of Report:
2016. 12. 16
Producer:
(Tina Huang/Administrator)
Signatory:
(Ben Cheng/Manager)
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 5 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
1. REPORT HISTORY
Revision
Date
Revision Summary
Report Number
2016. 12. 16
Original Report.
EM-F160857
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 6 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
2. SUMMARY OF TEST RESULTS
Rule
Description
Results
15.207
Conducted Emission
PASS
15.247(d)/
15.205
Radiated Band Edge and
Radiated Spurious Emission
PASS
15.247(a)(1)
20dB Bandwidth
PASS
15.247(a)(1)
Carrier Frequency Separation
PASS
15.247(a)(1)(iii)
Time of Occupancy
PASS
15.247(a)(1)(iii)
Number of Hopping Channels
PASS
15.247(b)(1)
Maximum Peak Output Power
PASS
15.247(d)
Conducted Band Edges and
Conducted Spurious Emission
PASS
15.203
Antenna Requirement
PASS
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 7 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
3. GENERAL INFORMATION
3.1. Description of EUT
Product
ENT CONSOLE
(1)WT002 (2)WB001
Above two models difference are in inch of LCD panel and
antenna gain, otherwise include RF circuit are identical.
Please to refer following list:
Model Number
Model
Inch of LCD Panel
WT002
15.6” (SM5D2TV001)
WB001
10.2”
Both two models are test in conducted and radiated emission
measurement and model WT002 (max. antenna gain) is only
test in all RF conducted test items.
Serial Number
N/A
Applicant
Dyaco International Inc.
12F, No. 111, Songjiang Road, Taipei, Taiwan.
Manufacture
Dyaco Canada Inc.
5955 Don Murie Street Niagara Falls ON L2G 0A9 Canada
RF Features
WLAN:802.11b/g/n
Bluetooth: BT and BLE
2.4 GHz
Transmit Type
Date of Receipt of Sample
File Number: C1M1605327
802.11b
802.11g
802.11n-HT20
BT/BLE
1T1R
1T1R
1T1R
1T1R
2016. 10. 09
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 8 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
3.3. Antenna Information
Model: WT002
Antenna Part
Number
Manufacture
32505-001900-100-RS
SAN JOSE
Technology,
Inc.
No.
Antenna Type
PIFA
Frequency
(MHz)
2400
Max Gain (dBi)
0.84
2450
1.89
2500
0.84
Model: WB001
Antenna Part
Number
Manufacture
32505-003501-100-RS
SAN JOSE
Technology,
Inc.
No.
Antenna Type
PIFA
Frequency
(MHz)
2400
Max Gain (dBi)
1.74
2450
1.36
2500
1.20
3.4. EUT Specifications Assessed in Current Report
Mode
Bluetooth
File Number: C1M1605327
Fundamental Range
(MHz)
Channel
Number
Modulation
Data Rate
(Mbps)
2402-2480
79
FHSS (GFSK, π/4
DQPSK, 8-DPSK)
1/2/3
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 9 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Channel
Number
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
File Number: C1M1605327
Frequency
(MHz)
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
Tel: +886 2 26099301
Fax: +886 2 26099303
Channel List
Channel
Frequency
Number
(MHz)
27
2429
28
2430
29
2431
30
2432
31
2433
32
2434
33
2435
34
2436
35
2437
36
2438
37
2439
38
2440
39
2441
40
2442
41
2443
42
2444
43
2445
44
2446
45
2447
46
2448
47
2449
48
2450
49
2451
50
2452
51
2453
52
2454
53
2455
Channel
Number
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
Frequency
(MHz)
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 10 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
3.5. Test Configuration
Mode
Bluetooth
Duty Cycle (x)
N/A
T (ms)
2.89
Duty Cycle Factor (dB)
N/A
AC Conduction
Test Case
Normal operation
Item
Radiated
Test Case
Radiated Band Edge Note1
Radiated Spurious Emission
Note1
20dB Bandwidth
Carrier Frequency
Separation
Time of Occupancy
Conducted
Number of Hopping
Test Case
Channels
Note2
Maximum Peak Output
Power
Band Edges
Spurious Emission
Modulation
GFSK
Data Rate
1Mbps
Test Channel
00/78
8-DPSK
3Mbps
00/78
GFSK
1Mbps
00/39/78
GFSK
1Mbps
00/39/78
8-DPSK
3Mbps
00/39/78
GFSK
1Mbps
00/39/78
8-DPSK
3Mbps
00/39/78
GFSK
1Mbps
00/39/78
8-DPSK
3Mbps
00/39/78
GFSK
1Mbps
39
8-DPSK
3Mbps
39
GFSK
1Mbps
00/39/78
8-DPSK
3Mbps
00/39/78
GFSK
1Mbps
00/78
8-DPSK
3Mbps
00/78
GFSK
1Mbps
00/39/78
8-DPSK
3Mbps
00/39/78
Note 1:
Note 1:
■Mobile Device, and 3 axis were assessed. The worst scenario for Radiated Spurious
Emission as follow:
■ Lie
□ Side
□ Stand
□Portable Device, and 3 axis were assessed. The worst scenario for Radiated Spurious
Emission as follow:
□ Lie
□ Side
□ Stand
Note 2: Low, mid, and high channels were measured, only the worst channel of each
modulation was presented in this report.
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 11 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
3.6. Tested Supporting System List
3.6.1. Support Peripheral Unit
No.
1.
Product
AC/DC Adapter
Brand
Model No.
Serial No.
FCC ID
FSP
FSP060-DBAB1
N/A
N/A
3.6.2. Cable Lists
No.
1.
Cable Description Of The Above Support Units
DC Power Cord: Unshielded, Detachable, 1.5m, Bonded a ferrite core
AC Power Cord: Unshielded, Detachable, 1.8m
3.7. Setup Configuration
3.7.1. EUT Configuration for Power Line and Radiated Emission
3.7.2. EUT Configuration for Conducted Test Items
3.8. Operating Condition of EUT
To set EUT on WLAN function under continues transmitting and choosing data rate/
channel.
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 12 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
3.9. Description of Test Facility
Name of Test Firm
Audix Technology Corporation / EMC Department
No. 53-11, Dingfu, Linkou Dist., New Taipei City 244, Taiwan
Tel: +886-2-26092133
Fax: +886-2-26099303
Website : www.audixtech.com
Contact e-mail: sales@audixtech.com
Accreditations
The laboratory is accredited by following organizations under ISO/IEC
17025:2005
(1) NVLAP(USA)
NVLAP Lab Code 200077-0
(2) TAF(Taiwan)
No. 1724
(3) FCC OET Designation
No. TW1004 & TW1090
(4) VCCI (Japan)
Member No. 0237
Test Facilities
(1) No. 8 Shielding Room
(2) No. 1 3m Semi-Anechoic Chamber
(IC Test Site Registration No: 5183B-1)
(3) Fully Anechoic Chamber (IC Test Site Registration No: 5183B-4)
3.10.Measurement Uncertainty
Test Item
Conduction Test
Radiation Test
(Distance: 3m)
Frequency Range
Uncertainty
150kHz~30MHz
3.5dB
30MHz~1000MHz
 3.68dB
Above 1GHz
Remark:Uncertainty = kuc(y)
 5.82dB
Test Item
Uncertainty
20dB Bandwidth
0.2kHz
Carrier Frequency Separation
0.2kHz
Time of Occupancy
0.03sec
Maximum peak Output power
 0.52dB
Conducted Emission Limitations
 0.13dB
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 13 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
4. MEASUREMENT EQUIPMENT LIST
4.1. Conducted Emission Measurement
Item
Type
Manufacturer
Model No.
Serial No.
Cal. Date
Cal. Interval
1.
Test Receiver
R&S
ESR3
101774
2016. 02. 04
1 Year
2.
A.M.N.
R&S
ENV4200
825358/003
2016. 04. 21
1 Year
3.
L.I.S.N.
Kyoritsu
KNW-407
8-855-9
2016. 12. 23
1 Year
4.
Pulse Limiter
R&S
ESH3-Z2
100354
1 Year
5.
Test Software
Audix
e3
V.120619C
2016. 01. 17
N.C.R.
N.C.R.
4.2. Radiated Emission Measurement
4.2.1. Frequency Range 9kHz~1000MHz (Semi-Anechoic Chamber)
Item
Type
Manufacturer
1.
Spectrum Analyzer
2.
Test Receiver
Agilent
R&S
3.
Amplifier
4.
Model No.
Serial No.
Cal. Date
N9010A-526 MY53400071 2016. 09. 19
ESCS30
100338
2016. 06. 22
2944A06305 2016. 02. 23
Cal. Interval
1 Year
1 Year
HP
8447D
Bilog Antenna
CHASE
CBL6112D
33821
2016. 01. 30
1 Year
5.
Loop Antenna
R&S
HFH2-Z2
891847/27
2015. 12. 24
1 Year
6.
Test Software
Audix
e3
V.120619C
N.C.R.
N.C.R.
1 Year
4.2.2. Frequency Range Above 1GHz (Fully Anechoic Chamber)
Item
Type
Manufacturer
Model No.
1.
Spectrum Analyzer
Agilent
E4446A
2.
Amplifier
Sonoma
3.
2.4GHz Notch
Filter
4.
Horn Antenna
5.
Horn Antenna
6.
Test Software
Serial No.
Cal. Date
US44300366 2016. 08. 19
310N
187161
7NSL10-2441.
K&L
5E130.5-00
ETS-Lindgren
3117
00135902
EMCO
3116
2653
Audix
e3
V.6.110601
Cal. Interval
1 Year
2016. 06. 14
1 Year
2016. 07. 27
1 Year
2016. 03. 05
2016. 10. 24
N.C.R.
1 Year
1 Year
N.C.R.
4.3. RF Conducted Measurement
Item
Type
Manufacturer
1.
Spectrum Analyzer
Agilent
File Number: C1M1605327
Model No.
Serial No.
N9030A-526 US51350140
Cal. Date
Cal. Interval
2016. 06. 07
1 Year
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 14 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
5. CONDUCTED EMISSION MEASUREMET
5.1. Block Diagram of Test Setup
Shielded Room Setup Diagram
40cm
EUT
Peripherals
Test Receiver
80cm
Table
80 cm
Table
LISN
AMN
Ground Plane
5.2. Power Line Conducted Emission Limit
Conducted Limit
Quasi-Peak Level
Average Level
150kHz ~ 500kHz
66 ~ 56 dBV
56 ~ 46 dBV
500kHz ~ 5MHz
56 dBV
46 dBV
5MHz ~ 30MHz
60 dBV
50 dBV
Remark 1.: If the average limit is met when using a Quasi-Peak detector,
the measurement using the average detector is not required.
2.: The lower limit applies to the band edges.
Frequency
5.3. Test Procedure
5.3.1. To set up the EUT as indicated in ANSI C 63.10. The EUT was placed on the
table which has 80 cm height to the ground and 40 cm distance to the
conducting wall.
5.3.2. Power supplier of the EUT was connected to the AC mains through an
Artificial Mains Network (A.M.N.).
5.3.3. The AC power supplies to all peripheral devices must be provided through
line impedance stabilization network (L.I.S.N.)
5.3.4. Checking frequency range from 150 kHz to 30 MHz and record the emission
which does not have 20 dB below limit.
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 15 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
5.4. Conducted Emission Measurement Results
PASSED.
Test Date
2016/12/23
Temp./Hum.
Test Voltage
AC 120V, 60Hz
(via AC/DC Adapter)
Test Model
File Number: C1M1605327
24℃/46%
WT002
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 16 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Test Date
2016/12/23
Temp./Hum.
Test Voltage
AC 120V, 60Hz
(via AC/DC Adapter)
Test Model
File Number: C1M1605327
24℃/46%
WT002
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 17 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Test Date
2016/12/23
Temp./Hum.
Test Voltage
AC 120V, 60Hz
(via AC/DC Adapter)
Test Model
File Number: C1M1605327
24℃/46%
WB001
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 18 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Test Date
2016/12/23
Temp./Hum.
Test Voltage
AC 120V, 60Hz
(via AC/DC Adapter)
Test Model
File Number: C1M1605327
24℃/46%
WB001
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 19 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
6. RADIATED EMISSION MEASUREMENT
6.1. Block Diagram of Test Setup
6.1.1. Block Diagram of EUT
Indicated as section 3.6
6.1.2. Semi Anechoic Chamber (3m) Setup Diagram for 9kHz-30MHz
Antenna Tower
Antenna height is fixed to 1 m
3m
Turn Table
0.8m
Ground Plane
TEST EQUIPMENT
6.1.3. Semi-Anechoic Chamber (3m) Setup Diagram for 30-1000 MHz
Antenna Tower
Antenna height is varied from 1 m to 4 m
3m
Turn Table
0.8m
Ground Plane
TEST EQUIPMENT
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 20 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
6.1.4. Fully Anechoic Chamber (3m) Setup Diagram for above 1GHz
Antenna Tower
Antenna height is varied from 1 m to 4 m
3m
1.5 m
Turn Table
Ground Plane
TEST EQUIPMENT
6.2. Radiated Emission Limits
In any 100kHz bandwidth outside the frequency band, the radio frequency power
produced by the intentional radiator shall be at least 20dB below that in the 100kHz
bandwidth within the band that contains the highest level. In addition, radiated
emissions which fall in restricted bands, as defined in Section 15.205, must also
comply with the radiated emission limits specified as below.
Limits
Frequency (MHz)
Distance (m)
dBV/m
V/m
0.009 - 0.490
0.490 - 1.705
1.705 - 30
30 - 88
88- 216
216- 960
Above 960
300
30
30
Above 1000
67.6
2400/kHz
87.6
24000/kHz
29.5
30
40.0
100
43.5
150
46.0
200
54.0
500
74.0 dBV/m (Peak)
54.0 dBV/m (Average)
Remark:(1) dBV/m = 20 log (V/m)
(2) The tighter limit applies to the edge between two frequency bands.
(3) Distance refers to the distance in meters between the measuring instrument antenna and
the closed point of any part of the device or system.
(4) Fundamental and emission fall within operation band are exempted from this section.
(5) Pursuant to ANSI C63.10: 6.6.4.3, if the maximized peak measured value complies
with the average limit, then it is unnecessary to perform an average measurement.
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 21 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
6.3. Test Procedure
Frequency Range 9kHz~30MHz:
The EUT setup on the turn table which has 0.8 m height to the ground. The turn table
rotated 360 degrees and antenna fixed to 1 m to find the maximum emission level.
In order to find the maximum emission, all of the interface cables were manipulated
according to ANSI C63.10-2013 regulation.
(1) RBW = 9kHz with peak and average detector.
(2) Detector: average and peak (9kHz-490kHz)
Q.P. (490kHz-30MHz)
Frequency Range 30MHz ~ 40GHz:
The EUT setup on the turn find table which has 80 cm (for 30-1000 MHz) and 1.5m
(for above 1GHz) height to the ground. The turn table rotated 360 degrees and
antenna varied from 1 m to 4 m to find the maximum emission level. Both horizontal
and vertical polarization are required. In order to find the maximum emission, all of
the interface cables were manipulated according to ANSI C63.10-2013 regulation.
Frequency below 1 GHz:
Spectrum Analyzer is used for pre-testing with following setting:
(1) RBW = 120KHz
(2) VBW ≥ 3 x RBW.
(3) Detector = Peak.
(4) Sweep time = auto.
(5) Trace mode = max hold.
(6) Allow sweeps to continue until the trace stabilizes.
(7) When peak-detected value is lower than limit that the measurement using the Q.P.
detector is not required. Otherwise using Q.P. for finally measurement.
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 22 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Frequency above 1GHz to 10th harmonic:
Peak Detector:
(1) RBW = 1MHz
(2) VBW ≥ 3 x RBW.
(3) Detector = Peak.
(4) Sweep time = auto.
(5) Trace mode = max hold.
(6) Allow sweeps to continue until the trace stabilizes.
(7) When peak-detected value is lower than limit that the measurement using the
average detector is not required. Otherwise using average for finally measurement.
Average Detector:
■Option 1:
(1) RBW = 1 MHz
(2) VBW =1/T
(3) Detector = Peak.
(4) Sweep time = auto.
(5) Trace mode = max hold.
(6) Allow sweeps to continue until the trace stabilizes.
□Option 2:
Average Emission Level= Peak Emission Level+ D.C.C.F.
6.4. Measurement Result Explanation
■Peak Emission Level=Antenna Factor + Cable Loss + Meter Reading
■Average Emission Level l=Antenna Factor + Cable Loss + Meter Reading
□Average Emission Level= Peak Emission Level+ DCCF
Duty Cycle Correction Factor (DCCF)= 20log (TX on/100ms) presented in section
3.4
□ERP= Peak Emission Level-95.2dB-2.14dB
6.5. Test Results
PASSED.
Test Date
Test Voltage
File Number: C1M1605327
2016/11/21
Temp./Hum.
23℃/60%
AC 120V, 60Hz (via AC/DC Adapter)
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 23 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
6.5.1. Emissions within Restricted Frequency Bands
6.5.1.1. Frequency 9kHz~30MHz
The emissions (9kHz~30MHz) not reported for there is no
emission be found.
6.5.1.2. Frequency Below 1 GHz
Test Model: WT002
Modulation
8-DPSK
Frequency
TX 2441MHz
Antenna at Horizontal Polarization
Emission Antenna Cable
Frequency Factor
Loss
Meter
Reading
Emission
Level
(dBV/m) (dBV/m)
(MHz)
(dB/m)
(dB)
(dBV)
148.34
239.52
399.57
584.84
863.23
964.11
11.70
12.08
15.92
18.24
20.14
21.00
2.81
3.71
5.54
6.71
7.97
8.61
10.61
11.41
15.82
9.09
8.32
8.49
Limits
Margin
Detector
(dB)
25.12
27.20
37.28
34.04
36.43
38.10
43.50
46.00
46.00
46.00
46.00
54.00
18.38
18.80
8.72
11.96
9.57
15.90
Meter
Reading
Emission
Level
Limits
Margin
(dBV/m) (dBV/m)
Peak
Peak
Peak
Peak
Peak
Peak
Antenna at Vertical Polarization
Emission Antenna Cable
Frequency Factor
Loss
(MHz)
(dB/m)
(dB)
(dBV)
75.59
212.36
351.07
584.84
624.61
811.82
8.56
10.34
14.94
18.24
18.44
19.72
1.96
3.46
4.98
6.71
6.84
7.68
19.29
13.16
11.97
18.79
11.08
9.29
File Number: C1M1605327
29.81
26.96
31.89
43.74
36.36
36.69
Detector
40.00
43.50
46.00
46.00
46.00
46.00
(dB)
10.19
16.54
14.11
2.26
9.64
9.31
Peak
Peak
Peak
Peak
Peak
Peak
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 24 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Test Model: WB001
Modulation
8-DPSK
Frequency
TX 2441MHz
Antenna at Horizontal Polarization
Emission Antenna Cable
Frequency Factor
Loss
Meter
Reading
Emission
Level
(dBV/m) (dBV/m)
(MHz)
(dB/m)
(dB)
(dBV)
214.30
336.52
471.35
689.60
814.73
952.47
10.49
14.63
16.83
18.50
19.75
20.89
3.49
4.80
6.20
7.05
7.70
8.52
22.79
19.92
13.59
8.12
7.95
10.92
Limits
Margin
Detector
(dB)
36.77
39.35
36.62
33.67
35.40
40.33
43.50
46.00
46.00
46.00
46.00
46.00
6.73
6.65
9.38
12.33
10.60
5.67
Meter
Reading
Emission
Level
Limits
Margin
(dBV/m) (dBV/m)
Peak
Peak
Peak
Peak
Peak
Peak
Antenna at Vertical Polarization
Emission Antenna Cable
Frequency Factor
Loss
(MHz)
(dB/m)
(dB)
(dBV)
214.30
336.52
471.35
573.20
696.39
825.40
10.49
14.63
16.83
18.09
18.51
19.82
3.49
4.80
6.20
6.67
7.07
7.75
18.47
13.37
16.22
12.13
9.78
8.97
File Number: C1M1605327
32.45
32.80
39.25
36.89
35.36
36.54
Detector
43.50
46.00
46.00
46.00
46.00
46.00
(dB)
11.05
13.20
6.75
9.11
10.64
9.46
Peak
Peak
Peak
Peak
Peak
Peak
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 25 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
6.5.2. Frequency Above 1 GHz to 10th harmonics
Band Edge:
Test Model: WT002
Mode
8-DPSK
Frequency
TX 2402MHz
Antenna at Horizontal Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2346.96
32.08
6.02
13.56
2390.04
32.16
6.08
11.89
2401.92
32.16
6.09
52.43
Emission
Limits Margin
Level
Detector
(dBV/m) (dBV/m) (dB)
51.66
74.00
22.34
Peak
50.13
74.00
23.87
Peak
90.68
----Peak
Antenna at Horizontal Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2363.28
32.11
6.04
1.79
2390.04
32.16
6.08
0.95
2402.16
32.16
6.09
49.19
Emission
Limits Margin
Level
Detector
(dB)
(dBV/m) (dBV/m)
39.94
54.00
14.06 Average
39.19
54.00
14.81 Average
87.44
----- Average
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 26 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Mode
Tel: +886 2 26099301
Fax: +886 2 26099303
8-DPSK
Frequency
TX 2402MHz
Antenna at Vertical Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2337.60
32.08
6.01
14.08
2390.04
32.16
6.08
12.38
2402.04
32.16
6.09
50.38
Emission
Limits Margin
Level
Detector
(dBV/m) (dBV/m) (dB)
52.17
74.00
21.83
Peak
50.62
74.00
23.38
Peak
88.63
----Peak
Antenna at Vertical Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2340.12
32.08
6.01
1.75
2390.04
32.16
6.08
1.15
2402.16
32.16
6.09
47.07
Emission
Limits Margin
Level
Detector
(dBV/m) (dBV/m) (dB)
39.84
54.00
14.16 Average
39.39
54.00
14.61 Average
85.32
----- Average
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 27 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Mode
Tel: +886 2 26099301
Fax: +886 2 26099303
8-DPSK
Frequency
TX 2480MHz
Antenna at Horizontal Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2480.08
32.28
6.18
49.67
2483.52
32.28
6.19
12.38
2517.68
32.32
6.23
13.64
Emission
Limits Margin
Level
Detector
(dB)
(dBV/m) (dBV/m)
88.13
----Peak
50.85
74.00
23.15
Peak
52.19
74.00
21.81
Peak
Antenna at Horizontal Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2480.00
32.28
6.18
46.29
2483.52
32.28
6.19
1.43
2510.08
32.32
6.22
1.88
Emission
Limits Margin
Level
Detector
(dB)
(dBV/m) (dBV/m)
84.75
----- Average
39.90
54.00
14.10 Average
40.42
54.00
13.58 Average
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 28 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Mode
Tel: +886 2 26099301
Fax: +886 2 26099303
8-DPSK
Frequency
TX 2480MHz
Antenna at Vertical Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2480.00
32.28
6.18
47.48
2483.52
32.28
6.19
12.21
2501.60
32.30
6.21
13.91
Emission
Limits Margin
Level
Detector
(dBV/m) (dBV/m) (dB)
85.94
----Peak
50.68
74.00
23.32
Peak
52.42
74.00
21.58
Peak
Antenna at Vertical Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2480.00
32.28
6.18
43.54
2483.52
32.28
6.19
1.46
2508.56
32.32
6.22
2.02
Emission
Limits Margin
Level
Detector
(dBV/m) (dBV/m) (dB)
82.00
----- Average
39.93
54.00
14.07 Average
40.56
54.00
13.44 Average
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 29 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Test Model: WB001
Mode
8-DPSK
Frequency
TX 2402MHz
Antenna at Horizontal Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2356.80
32.11
6.04
13.49
2390.04
32.16
6.08
11.78
2401.92
32.16
6.09
48.06
Emission
Limits Margin
Level
Detector
(dBV/m) (dBV/m) (dB)
51.64
74.00
22.36
Peak
50.02
74.00
23.98
Peak
86.31
----Peak
Antenna at Horizontal Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2354.76
32.11
6.03
3.20
2390.04
32.16
6.08
2.79
2402.04
32.16
6.09
45.46
Emission
Limits Margin
Level
Detector
(dBV/m) (dBV/m) (dB)
41.34
54.00
12.66 Average
41.03
54.00
12.97 Average
83.71
----- Average
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 30 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Mode
Tel: +886 2 26099301
Fax: +886 2 26099303
8-DPSK
Frequency
TX 2402MHz
Antenna at Vertical Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2349.24
32.08
6.03
13.59
2390.04
32.16
6.08
11.99
2402.04
32.16
6.09
49.31
Emission
Limits Margin
Level
Detector
(dBV/m) (dBV/m) (dB)
51.70
74.00
22.30
Peak
50.23
74.00
23.77
Peak
87.56
----Peak
Antenna at Vertical Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2365.68
32.11
6.05
3.06
2390.04
32.16
6.08
2.90
2402.04
32.16
6.09
46.55
Emission
Limits Margin
Level
Detector
(dBV/m) (dBV/m) (dB)
41.22
54.00
12.78 Average
41.14
54.00
12.86 Average
84.80
----- Average
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 31 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Mode
Tel: +886 2 26099301
Fax: +886 2 26099303
8-DPSK
Frequency
TX 2480MHz
Antenna at Horizontal Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2479.92
32.28
6.18
47.60
2483.52
32.28
6.19
12.66
2509.20
32.32
6.22
13.51
Emission
Limits Margin
Level
Detector
(dB)
(dBV/m) (dBV/m)
86.06
----Peak
51.13
74.00
22.87
Peak
52.05
74.00
21.95
Peak
Antenna at Horizontal Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2480.00
32.28
6.18
44.06
2483.52
32.28
6.19
2.68
2504.64
32.32
6.21
3.46
Emission
Limits Margin
Level
Detector
(dB)
(dBV/m) (dBV/m)
82.52
----- Average
41.15
54.00
12.85 Average
41.99
54.00
12.01 Average
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 32 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Mode
Tel: +886 2 26099301
Fax: +886 2 26099303
8-DPSK
Frequency
TX 2480MHz
Antenna at Vertical Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2479.92
32.28
6.18
48.30
2483.52
32.28
6.19
11.95
2515.60
32.32
6.22
13.86
Emission
Limits Margin
Level
Detector
(dBV/m) (dBV/m) (dB)
86.76
----Peak
50.42
74.00
23.58
Peak
52.40
74.00
21.60
Peak
Antenna at Vertical Polarization
Emission Antenna Cable
Meter
Frequency Factor
Loss
Reading
(MHz)
(dB/m) (dB)
(dBV)
2480.24
32.28
6.18
45.45
2483.52
32.28
6.19
2.66
2513.60
32.32
6.22
3.12
Emission
Limits Margin
Level
Detector
(dBV/m) (dBV/m) (dB)
83.91
----- Average
41.13
54.00
12.87 Average
41.66
54.00
12.34 Average
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 33 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
6.5.3. Emissions outside the frequency band:
The emissions (up to 25GHz) not reported for there is no emission be found.
Test Model: WT002
Modulation
8-DPSK
Frequency
TX 2402MHz
Antenna at Horizontal Polarization
Emission Antenna Cable
Frequency Factor
Loss
Meter
Reading
Emission
Level
(dBV/m) (dBV/m)
(MHz)
(dB/m)
(dB)
(dBV)
4805.00
7205.00
34.22
35.80
8.87
11.27
0.55
-2.20
Limits
Margin
Detector
(dB)
43.64
44.87
54.00
54.00
10.36
9.13
Meter
Reading
Emission
Level
Limits
Margin
(dBV/m) (dBV/m)
Peak
Peak
Antenna at Vertical Polarization
Emission Antenna Cable
Frequency Factor
Loss
(MHz)
(dB/m)
(dB)
(dBV)
4805.00
7205.00
34.22
35.80
8.87
11.27
0.34
-1.99
File Number: C1M1605327
43.43
45.08
Detector
54.00
54.00
(dB)
10.57
8.92
Peak
Peak
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 34 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Modulation
Tel: +886 2 26099301
Fax: +886 2 26099303
8-DPSK
Frequency
TX 2441MHz
Antenna at Horizontal Polarization
Emission Antenna Cable
Frequency Factor
Loss
Meter
Reading
Emission
Level
(dBV/m) (dBV/m)
(MHz)
(dB/m)
(dB)
(dBV)
4880.00
7320.00
34.25
35.80
9.14
11.80
0.47
-2.51
Limits
Margin
Detector
(dB)
43.86
45.09
54.00
54.00
10.14
8.91
Meter
Reading
Emission
Level
Limits
Margin
(dBV/m) (dBV/m)
Peak
Peak
Antenna at Vertical Polarization
Emission Antenna Cable
Frequency Factor
Loss
(MHz)
(dB/m)
(dB)
(dBV)
4880.00
7320.00
34.25
35.80
9.14
11.80
0.25
-1.72
Modulation
8-DPSK
43.64
45.88
Detector
54.00
54.00
Frequency
(dB)
10.36
8.12
Peak
Peak
TX 2480MHz
Antenna at Horizontal Polarization
Emission Antenna Cable
Frequency Factor
Loss
Meter
Reading
Emission
Level
(dBV/m) (dBV/m)
(MHz)
(dB/m)
(dB)
(dBV)
4960.00
7440.00
34.29
35.80
9.40
12.56
1.10
-2.51
Limits
Margin
Detector
(dB)
44.79
45.85
54.00
54.00
9.21
8.15
Meter
Reading
Emission
Level
Limits
Margin
(dBV/m) (dBV/m)
Peak
Peak
Antenna at Vertical Polarization
Emission Antenna Cable
Frequency Factor
Loss
(MHz)
(dB/m)
(dB)
(dBV)
4960.00
7440.00
34.29
35.80
9.40
12.56
1.51
-2.94
File Number: C1M1605327
45.20
45.42
Detector
54.00
54.00
(dB)
8.80
8.58
Peak
Peak
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 35 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Test Model: WB001
Modulation
8-DPSK
Frequency
TX 2402MHz
Antenna at Horizontal Polarization
Emission Antenna Cable
Frequency Factor
Loss
Meter
Reading
Emission
Level
(dBV/m) (dBV/m)
(MHz)
(dB/m)
(dB)
(dBV)
4805.00
7205.00
34.22
35.80
8.87
11.27
-0.27
-0.81
Limits
Margin
Detector
(dB)
42.82
46.26
54.00
54.00
11.18
7.74
Meter
Reading
Emission
Level
Limits
Margin
(dBV/m) (dBV/m)
Peak
Peak
Antenna at Vertical Polarization
Emission Antenna Cable
Frequency Factor
Loss
(MHz)
(dB/m)
(dB)
(dBV)
4805.00
7205.00
34.22
35.80
8.87
11.27
0.97
-1.00
File Number: C1M1605327
44.06
46.07
Detector
54.00
54.00
(dB)
9.94
7.93
Peak
Peak
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 36 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Modulation
Tel: +886 2 26099301
Fax: +886 2 26099303
8-DPSK
Frequency
TX 2441MHz
Antenna at Horizontal Polarization
Emission Antenna Cable
Frequency Factor
Loss
Meter
Reading
Emission
Level
(dBV/m) (dBV/m)
(MHz)
(dB/m)
(dB)
(dBV)
4880.00
7325.00
34.25
35.80
9.14
11.95
0.85
-1.34
Limits
Margin
Detector
(dB)
44.24
46.41
54.00
54.00
9.76
7.59
Meter
Reading
Emission
Level
Limits
Margin
(dBV/m) (dBV/m)
Peak
Peak
Antenna at Vertical Polarization
Emission Antenna Cable
Frequency Factor
Loss
(MHz)
(dB/m)
(dB)
(dBV)
4880.00
7325.00
34.25
35.80
9.14
11.95
0.26
-2.00
Modulation
8-DPSK
43.65
45.75
Detector
54.00
54.00
Frequency
(dB)
10.35
8.25
Peak
Peak
TX 2480MHz
Antenna at Horizontal Polarization
Emission Antenna Cable
Frequency Factor
Loss
Meter
Reading
Emission
Level
(dBV/m) (dBV/m)
(MHz)
(dB/m)
(dB)
(dBV)
4960.00
7440.00
34.29
35.80
9.40
12.56
34.90
31.58
Limits
Margin
Detector
(dB)
44.18
45.19
54.00
54.00
9.82
8.81
Meter
Reading
Emission
Level
Limits
Margin
(dBV/m) (dBV/m)
Peak
Peak
Antenna at Vertical Polarization
Emission Antenna Cable
Frequency Factor
Loss
(MHz)
(dB/m)
(dB)
(dBV)
4960.00
7440.00
34.29
35.80
9.40
12.56
35.79
32.10
45.07
45.71
Detector
54.00
54.00
(dB)
8.93
8.29
Peak
Peak
6.5.4. Emissions in Non-restricted Frequency Bands
All emission levels below the 15.209 general radiated emissions limits is not
required.
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 37 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
7. 20dB BANDWIDTH MEASUREMENT
7.1. Block Diagram of Test Setup
7.2. Specification Limits
Alternatively, frequency hopping systems operating in the 2400-2483.5MHz band
may have hopping channel carrier frequencies that are separated by 25kHz or
two-thirds of the 20dB bandwidth of the hopping channel, whichever is greater.
7.3. Test Procedure
Following measurement procedure is reference to DA00-705:
(1) Set RBW close to1% of OBW.
(2) Set VBW≥RBW.
(3) Detector = Peak.
(4) Trace mode = max hold.
(5) Sweep = auto couple.
(6) Allow the trace to stabilize.
(7) Setting channel bandwidth function x dB to -20 dB to record the final bandwidth.
7.4. Test Results
Please refer to Appendix A
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 38 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
8. CARRIER FREQUENCY SEPARATION MEASUREMENT
8.1. Block Diagram of Test Setup
8.2. Specification Limits
Alternatively, frequency hopping systems operating in the 2400-2483.5MHz band
may have hopping channel carrier frequencies that are separated by 25kHz or
two-thirds of the 20dB bandwidth of the hopping channel, whichever is greater,
provided the systems operate with an output no greater than 125mW.
8.3. Test Procedure
Following measurement procedure is reference to DA00-705:
(1) Span = wide enough to capture the peaks of two adjacent channels
(2) RBW  1% of the span
(3) VBW RBW
(4) Sweep = auto
(5) Detector function = peak
(6) Trace = max hold
8.4. Test Results
Please refer to Appendix A
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 39 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
9. TIME OF OCCUPANCY MEASUREMENT
9.1. Block Diagram of Test Setup
9.2. Specification Limits
Frequency hopping systems in the 2400-2483.5MHz shall use at least 15
non-overlapping channels. The average time of occupancy on any channel shall not
be greater than 0.4 seconds within a period of 0.4 seconds multiplied by number of
hopping channels employed.
9.3. Test Procedure
Following measurement procedure is reference to DA00-705:
(1) Span = zero span, centered on a hopping channel
(2) RBW = 1 MHz
(3) VBW  RBW
(4) Sweep = as necessary to capture the entire dwell time per hopping channel
(5) Detector function = peak
(6) Trace = max hold
9.4. Test Results
Please refer to Appendix A
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 40 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
10. NUMBER OF HOPPING CHANNELS MEASUREMENT
10.1. Block Diagram of Test Setup
10.2. Specification Limits
Frequency hopping systems which use fewer than 20 hopping frequencies may
employ intelligent hopping techniques to avoid interference to other transmissions.
Frequency hopping systems may avoid or suppress transmissions on a particular
hopping frequency provided that a minimum of 15 non-overlapping channels.
10.3. Test Procedure
Following measurement procedure is reference to DA00-705:
(1) Span = the frequency band of operation
(2) RBW  1% of the span
(3) VBW  RBW
(4) Sweep = auto
(5) Detector function = peak
(6) Trace = max hold
10.4. Test Results
Please refer to Appendix A
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 41 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
11. MAXIMUM PEAK OUTPUT POWER MEASUREMENT
11.1.Block Diagram of Test Setup
11.2.Specification Limits
The Limits of maximum Peak Output Power for frequency hopping systems in
2400-2483.5MHz is: 0.125Watt. (21dBm)
11.3.Test Procedure
Following measurement procedure is reference to DA00-705:
(1) Span = approximately 5 times the 20 dB bandwidth, centered on a hopping
channel
(2) RBW  1% of the span
(3) VBW  RBW
(4) Sweep = auto
(5) Detector function = peak
(6) Trace = max hold
11.4. Test Results
Please refer to Appendix A
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 42 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
12. EMISSION LIMITATIONS MEASUREMENT
12.1. Block Diagram of Test Setup
12.2. Specification Limits
In any 100kHz bandwidth outside the frequency band in which the spread spectrum
or digitally modulated intentional radiator is operating, the radio frequency power
that is produced by the intentional radiator shall be at least 20dB below that in the
100kHz bandwidth within the band that contains the highest level of the desired
power, based on either an RF conducted or a radiated measurement. Attenuation
below the general limits specified in Section 15.209(a) is not required. In addition,
radiated emissions which fall in restricted bands, as defined in Section 15.205(a),
must also comply with the radiated emission limits specified in Section 15.209(a)
(See Section 15.205(c)).
12.3. Test Procedure
Following measurement procedure is reference to DA00-705:
(1) Set span wide enough to capture the peak level of the in-band emission and all
spurious emissions; up to 10th harmonic.
(2) RBW = 100 kHz
(3) VBW  RBW
(4) Sweep = auto
(5) Detector function = peak
(6) Trace = max hold
12.4. Test Results
Please refer to Appendix A
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Page 43 of 43
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
13. DEVIATION TO TEST SPECIFICATIONS
NONE
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by AUDIX Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A
Audix Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
APPENDIX A
TEST Data and PLOTS
(Model: WT002)
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 1 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
TABLE OF CONTENTS
A.1 20dB BANDWIDTH MEASUREMENT ................................................................................ 2
A.1.1
20dB Bandwidth Result ............................................................................................................. 2
A.1.2
Measurement Plots .................................................................................................................... 3
A.2 CARRIER FREQUENCY SEPARATION MEASUREMENT ............................................ 4
A.2.1
Measurement Plots .................................................................................................................... 4
A.3 TIME OF OCCUPANCY MEASUREMENT ....................................................................... 6
A.3.1
Time of Occupancy.................................................................................................................... 6
A.3.2
Measurement Plots .................................................................................................................. 10
A.4 NUMBER OF HOPPING CHANNELS MEASUREMENT .............................................. 16
A.4.1
Measurement Plots .................................................................................................................. 16
A.5 MAXIMUM PEAK OUTPUT POWER MEASUREMENT .............................................. 17
A.5.1
Output Power ........................................................................................................................... 17
A.5.2
Measurement Plots .................................................................................................................. 18
A.6 EMISSION LIMITATIONS MEASUREMENT ................................................................. 19
A.6.1
Band Edge ............................................................................................................................... 19
A.6.2
Spurious Emission ................................................................................................................... 21
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 2 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
A.1 20dB BANDWIDTH MEASUREMENT
Test Date
Cable Loss
2016/11/14
Temp./Hum.
24℃/55%
0.54dB
Test Voltage
AC 120V, 60Hz
(via AC/DC Adapter)
Test Model
WT002
A.1.1 20dB Bandwidth Result
Modulation
GFSK
Centre Frequency
(MHz)
20 dB Bandwidth
(MHz)
2/3 (20dB Bandwidth)
2402
0.9173
0.612
2441
0.9173
0.612
2480
0.9170
0.611
Remark: The maximum two-thirds of the 20dB bandwidth is the limit for carrier frequency
separation presented.
Modulation
8-DPSK
Centre Frequency
(MHz)
20 dB Bandwidth
(MHz)
2/3 (20dB Bandwidth)
2402
1.262
0.841
2441
1.262
0.841
2480
1.263
0.842
Remark: The maximum two-thirds of the 20dB bandwidth is the limit for carrier frequency
separation presented.
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 3 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
A.1.2 Measurement Plots
Modulation: GFSK
File Number: C1M1605327
Modulation: 8-DPSK
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 4 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
A.2 CARRIER FREQUENCY SEPARATION MEASUREMENT
Test Date
2016/11/14
Cable Loss
0.54dB
Test Model
Temp./Hum.
24℃/55%
Test Voltage
AC 120V, 60Hz
(via AC Adapter)
WT002
A.2.1 Measurement Plots
Modulation: GFSK
2402MHz
2441MHz
adjacent channel of right carrier frequency
2441MHz
adjacent channel of left carrier frequency
2480MHz
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 5 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Modulation: 8-DPSK
2402MHz
2441MHz
adjacent channel of right carrier frequency
2441MHz
adjacent channel of left carrier frequency
2480MHz
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 6 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
A.3 TIME OF OCCUPANCY MEASUREMENT
Test Date
Cable Loss
2016/11/14
Temp./Hum.
24℃/55%
0.54dB
Test Voltage
AC 120V, 60Hz
(via AC/DC Adapter)
Test Model
WT002
A.3.1 Time of Occupancy
Modulation
Centre Frequency
(MHz)
2402
GFSK
2441
2480
Mode
Time of
Maximum accumulated
Occupancy (ms) Time of Occupancy (ms)
Limit
(ms)
DH1
0.380
120.080
<400
DH3
1.642
259.436
<400
DH5
2.890
273.972
<400
DH1
0.385
121.660
<400
DH3
1.642
259.436
<400
DH5
2.880
273.024
<400
DH1
0.380
120.080
<400
DH3
1.635
258.330
<400
DH5
2.890
273.972
<400
Observation Period: 79 channels*0.4 seconds = 31.6 seconds
Centre Frequency: 2402MHz
DH1: For each second of 6 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 120.080
ms
10 channels*31.6 seconds*
0.38
DH3: For each second of 5 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 259.436
ms
5 channels*31.6 seconds*
1.642
DH5: For each second of 3 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 273.972
ms
3 channels*31.6 seconds*
2.89
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 7 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Centre Frequency: 2441MHz
DH1: For each second of 6 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 121.660
ms
10 channels*31.6 seconds*
0.385
DH3: For each second of 5 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 259.436
ms
5 channels*31.6 seconds*
1.642
DH5: For each second of 3 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 273.024
ms
3 channels*31.6 seconds*
2.88
Centre Frequency: 2480MHz
DH1: For each second of 6 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 120.080
ms
10 channels*31.6 seconds*
0.38
DH3: For each second of 5 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 258.330
ms
5 channels*31.6 seconds*
1.635
DH5: For each second of 3 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 273.972
ms
3 channels*31.6 seconds*
2.89
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 8 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Modulation
Centre Frequency
(MHz)
2402
8-DPSK
2441
2480
Tel: +886 2 26099301
Fax: +886 2 26099303
Mode
Time of
Maximum accumulated
Occupancy (ms) Time of Occupancy (ms)
Limit
(ms)
3DH1
0.390
123.240
<400
3DH3
1.642
311.323
<400
3DH5
2.890
365.296
<400
3DH1
0.395
124.820
<400
3DH3
1.642
311.323
<400
3DH5
2.890
365.296
<400
3DH1
0.390
123.240
<400
3DH3
1.642
311.323
<400
3DH5
2.890
365.296
<400
Observation Period: 79 channels*0.4 seconds = 31.6 seconds
Centre Frequency: 2402MHz
3DH1: For each second of 10 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 123.240
ms
10 channels*31.6 seconds*
0.39
3DH3: For each second of 4 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 311.323
ms
6 channels*31.6 seconds*
1.642
3DH5: For each second of 2 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 365.296
ms
4 channels*31.6 seconds*
2.89
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 9 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Centre Frequency: 2441MHz
3DH1: For each second of 6 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 124.820
ms
10 channels*31.6 seconds*
0.395
3DH3: For each second of 4 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 311.323
ms
6 channels*31.6 seconds*
1.642
3DH5: For each second of 2 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 365.296
ms
4 channels*31.6 seconds*
2.89
Centre Frequency: 2480MHz
3DH1: For each second of 6 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 123.240
ms
10 channels*31.6 seconds*
0.39
3DH3: For each second of 4 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 311.323
ms
6 channels*31.6 seconds*
1.642
3DH5: For each second of 2 channel appearance, the longest time of occupancy for
each of 31.6 seconds is:
ms= 365.296
ms
4 channels*31.6 seconds*
2.89
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 10 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
A.3.2 Measurement Plots
Modulation: GFSK
Centre Frequency: 2402MHz
Mode: DH1
Mode: DH3
Mode: DH5
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 11 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Modulation: GFSK
Centre Frequency: 2441MHz
Mode: DH1
Mode: DH3
Mode: DH5
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 12 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Modulation: GFSK
Centre Frequency: 2480MHz
Mode: DH1
Mode: DH3
Mode: DH5
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 13 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Modulation: 8-DPSK
Centre Frequency: 2402MHz
Mode: 3DH1
Mode: 3DH3
Mode: 3DH5
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 14 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Modulation: 8-DPSK
Centre Frequency: 2441MHz
Mode: 3DH1
Mode: 3DH3
Mode: 3DH5
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 15 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Modulation: 8-DPSK
Centre Frequency: 2480MHz
Mode: 3DH1
Mode: 3DH3
Mode: 3DH5
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 16 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
A.4 NUMBER OF HOPPING CHANNELS MEASUREMENT
Test Date
Cable Loss
2016/11/14
Temp./Hum.
24℃/55%
0.54dB
Test Voltage
AC 120V, 60Hz
(via AC/DC Adapter)
Test Model
WT002
A.4.1 Measurement Plots
Modulation: GFSK
The number hopping channel is 79.
File Number: C1M1605327
Modulation: 8-DPSK
The number hopping channel is 79.
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 17 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
A.5 MAXIMUM PEAK OUTPUT POWER MEASUREMENT
Test Date
2016/11/24
Temp./Hum.
24℃/55%
0.54dB
Test Voltage
AC 120V, 60Hz
(via AC/DC Adapter)
Cable Loss
Test Model
WT002
A.5.1 Output Power
Modulation
dBm
2402
-0.705
0.000850
2441
0.264
0.001063
2480
0.127
0.001030
GFSK
Modulation
Peak Output Power
Centre Frequency
(MHz)
Limit
Peak Output Power
Centre Frequency
(MHz)
dBm
2402
-0.481
0.000895
2441
0.480
0.001117
2480
0.400
0.001096
8-DPSK
File Number: C1M1605327
21dBm
(0.125W)
Limit
21dBm
(0.125W)
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 18 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
A.5.2 Measurement Plots
Modulation: GFSK
File Number: C1M1605327
Modulation: 8-DPSK
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 19 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
A.6 EMISSION LIMITATIONS MEASUREMENT
A.6.1 Band Edge
Test Date
Cable Loss
2016/11/14
Temp./Hum.
24℃/55%
0.54dB
Test Voltage
AC 120V, 60Hz
(via AC/DC Adapter)
Test Model
WT002
Modulation: GFSK
Single Channel
Low channel
High channel
Hopping Mode
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 20 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
Modulation: 8-DPSK
Single Channel
Low channel
High channel
Hopping Mode
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 21 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Tel: +886 2 26099301
Fax: +886 2 26099303
A.6.2 Spurious Emission
Test Date
2016/11/14
Temp./Hum.
24℃/55%
2402MHz
Modulation
GFSK
Frequency
Cable Loss
0.54dB
Test Voltage
Test Model
AC 120V, 60Hz
(via AC/DC Adapter)
WT002
30MHz – 8GHz
8GHz – 15GHz
15GHz – 25GHz
Note: All results have been included cable loss.
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 22 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Test Date
Tel: +886 2 26099301
Fax: +886 2 26099303
2016/11/14
Temp./Hum.
24℃/55%
2441MHz
Modulation
GFSK
Frequency
Cable Loss
0.54dB
Test Voltage
Test Model
AC 120V, 60Hz
(via AC/DC Adapter)
WT002
30MHz – 8GHz
8GHz – 15GHz
15GHz – 25GHz
Note: All results have been included cable loss.
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 23 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Test Date
Tel: +886 2 26099301
Fax: +886 2 26099303
2016/11/14
Temp./Hum.
24℃/55%
2480MHz
Modulation
GFSK
Frequency
Cable Loss
0.54dB
Test Voltage
Test Model
AC 120V, 60Hz
(via AC/DC Adapter)
WT002
30MHz – 8GHz
8GHz – 15GHz
15GHz – 25GHz
Note: All results have been included cable loss.
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 24 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Test Date
Tel: +886 2 26099301
Fax: +886 2 26099303
2016/11/14
Temp./Hum.
24℃/55%
2402MHz
Modulation
8-DPSK
Frequency
Cable Loss
0.54dB
Test Voltage
Test Model
AC 120V, 60Hz
(via AC/DC Adapter)
WT002
30MHz – 8GHz
8GHz – 15GHz
15GHz – 25GHz
Note: All results have been included cable loss.
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 25 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Test Date
Tel: +886 2 26099301
Fax: +886 2 26099303
2016/11/14
Temp./Hum.
24℃/55%
2441MHz
Modulation
8-DPSK
Frequency
Cable Loss
0.54dB
Test Voltage
Test Model
AC 120V, 60Hz
(via AC/DC Adapter)
WT002
30MHz – 8GHz
8GHz – 15GHz
15GHz – 25GHz
Note: All results have been included cable loss.
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
APPENDIX A-Page 26 of 26
AUDIX Technology Corp.
No. 53-11, Dingfu, Linkou, Dist.,
New Taipei City244, Taiwan
Test Date
Tel: +886 2 26099301
Fax: +886 2 26099303
2016/11/14
Temp./Hum.
24℃/55%
2480MHz
Modulation
8-DPSK
Frequency
Cable Loss
0.54dB
Test Voltage
Test Model
AC 120V, 60Hz
(via AC/DC Adapter)
WT002
30MHz – 8GHz
8GHz – 15GHz
15GHz – 25GHz
Note: All results have been included cable loss.
File Number: C1M1605327
Report Number: EM-F160857
This test report may be reproduced in full only. The document may only be updated by Audix Technology
Corp. personnel. Any changes will be noted in the Document History section of the report.
Download: IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Mirror Download [FCC.gov]IEITB1DYACO ENT CONSOLE Test Report (BT)-Rev.01(170605) Dyaco International Inc.
Document ID3421226
Application IDZYyDNi8/LmOrp+aBts9e2w==
Document DescriptionTest Report (BT)-Rev.01(170605)
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize275.17kB (3439589 bits)
Date Submitted2017-06-11 00:00:00
Date Available2017-06-12 00:00:00
Creation Date2017-10-22 23:49:06
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-10-22 23:49:06
Document TitleTest Report (BT)-Rev.01(170605)
Document CreatorPScript5.dll Version 5.2.2
Document Author: tina_huang

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 1
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:f9691ab0-9741-11f2-0000-02c7314339d4
Producer                        : GPL Ghostscript 9.18
Modify Date                     : 2017:07:02 12:53:20Z
Create Date                     : 2017:07:02 12:53:20Z
Creator Tool                    : UnknownApplication
Document ID                     : uuid:f9691ab0-9741-11f2-0000-02c7314339d4
Format                          : application/pdf
Title                           : Untitled